Cargando…

Novel Computerized Method for Measurement of Retinal Vessel Diameters

Several clinical studies reveal the relationship between alterations in the topologies of the human retinal blood vessel, the outcrop and the disease evolution, such as diabetic retinopathy, hypertensive retinopathy, and macular degeneration. Indeed, the detection of these vascular changes always ha...

Descripción completa

Detalles Bibliográficos
Autores principales: Guedri, Hichem, Ben Abdallah, Mariem, Echouchene, Fraj, Belmabrouk, Hafedh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5489798/
https://www.ncbi.nlm.nih.gov/pubmed/28536355
http://dx.doi.org/10.3390/biomedicines5020012
_version_ 1783246862123270144
author Guedri, Hichem
Ben Abdallah, Mariem
Echouchene, Fraj
Belmabrouk, Hafedh
author_facet Guedri, Hichem
Ben Abdallah, Mariem
Echouchene, Fraj
Belmabrouk, Hafedh
author_sort Guedri, Hichem
collection PubMed
description Several clinical studies reveal the relationship between alterations in the topologies of the human retinal blood vessel, the outcrop and the disease evolution, such as diabetic retinopathy, hypertensive retinopathy, and macular degeneration. Indeed, the detection of these vascular changes always has gaps. In addition, the manual steps are slow, which may be subjected to a bias of the perceiver. However, we can overcome these troubles using computer algorithms that are quicker and more accurate. This paper presents and investigates a novel method for measuring the blood vessel diameter in the retinal image. The proposed method is based on a thresholding segmentation and thinning step, followed by the characteristic point determination step by the Douglas-Peucker algorithm. Thereafter, it uses the active contours to detect vessel contour. Finally, Heron’s Formula is applied to assure the calculation of vessel diameter. The obtained results for six sample images showed that the proposed method generated less errors compared to other techniques, which confirms the high performance of the proposed method.
format Online
Article
Text
id pubmed-5489798
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-54897982017-06-30 Novel Computerized Method for Measurement of Retinal Vessel Diameters Guedri, Hichem Ben Abdallah, Mariem Echouchene, Fraj Belmabrouk, Hafedh Biomedicines Article Several clinical studies reveal the relationship between alterations in the topologies of the human retinal blood vessel, the outcrop and the disease evolution, such as diabetic retinopathy, hypertensive retinopathy, and macular degeneration. Indeed, the detection of these vascular changes always has gaps. In addition, the manual steps are slow, which may be subjected to a bias of the perceiver. However, we can overcome these troubles using computer algorithms that are quicker and more accurate. This paper presents and investigates a novel method for measuring the blood vessel diameter in the retinal image. The proposed method is based on a thresholding segmentation and thinning step, followed by the characteristic point determination step by the Douglas-Peucker algorithm. Thereafter, it uses the active contours to detect vessel contour. Finally, Heron’s Formula is applied to assure the calculation of vessel diameter. The obtained results for six sample images showed that the proposed method generated less errors compared to other techniques, which confirms the high performance of the proposed method. MDPI 2017-03-27 /pmc/articles/PMC5489798/ /pubmed/28536355 http://dx.doi.org/10.3390/biomedicines5020012 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Guedri, Hichem
Ben Abdallah, Mariem
Echouchene, Fraj
Belmabrouk, Hafedh
Novel Computerized Method for Measurement of Retinal Vessel Diameters
title Novel Computerized Method for Measurement of Retinal Vessel Diameters
title_full Novel Computerized Method for Measurement of Retinal Vessel Diameters
title_fullStr Novel Computerized Method for Measurement of Retinal Vessel Diameters
title_full_unstemmed Novel Computerized Method for Measurement of Retinal Vessel Diameters
title_short Novel Computerized Method for Measurement of Retinal Vessel Diameters
title_sort novel computerized method for measurement of retinal vessel diameters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5489798/
https://www.ncbi.nlm.nih.gov/pubmed/28536355
http://dx.doi.org/10.3390/biomedicines5020012
work_keys_str_mv AT guedrihichem novelcomputerizedmethodformeasurementofretinalvesseldiameters
AT benabdallahmariem novelcomputerizedmethodformeasurementofretinalvesseldiameters
AT echouchenefraj novelcomputerizedmethodformeasurementofretinalvesseldiameters
AT belmabroukhafedh novelcomputerizedmethodformeasurementofretinalvesseldiameters