Cargando…
ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques
BACKGROUND AND OBJECTIVES: The laryngeal mask airway (LMA) ProSeal is most commonly used supraglottic airway device; it is routinely inserted by blind technique. Although blind insertion technique is most widely used, there are many techniques which are available such as priming the drain tube with...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5490140/ https://www.ncbi.nlm.nih.gov/pubmed/28663626 http://dx.doi.org/10.4103/0259-1162.206274 |
_version_ | 1783246925319897088 |
---|---|
author | Patil, Pooja Chandrakanth Chikkapillappa, Manjunath Abloodu Pujara, Vinayak Seenappa Anandswamy, Tejesh Channasandra Parate, Leena Harshad Bevinaguddaiah, Yatish |
author_facet | Patil, Pooja Chandrakanth Chikkapillappa, Manjunath Abloodu Pujara, Vinayak Seenappa Anandswamy, Tejesh Channasandra Parate, Leena Harshad Bevinaguddaiah, Yatish |
author_sort | Patil, Pooja Chandrakanth |
collection | PubMed |
description | BACKGROUND AND OBJECTIVES: The laryngeal mask airway (LMA) ProSeal is most commonly used supraglottic airway device; it is routinely inserted by blind technique. Although blind insertion technique is most widely used, there are many techniques which are available such as priming the drain tube with a guiding instrument such as a suction catheter, a gum elastic bougie, a Flexi-Slip Stylet, direct laryngoscopy, and even a fiber-optic bronchoscope (FOB). The present study was undertaken to compare and assess the placement of LMA ProSeal using blind versus direct laryngoscopy techniques using FOB. MATERIALS AND METHODS: A prospective randomized comparative study of 110 patients divided into two groups of 55 each as Group I (blind insertion) and Group II (direct laryngoscopic insertion) after satisfying the inclusion criteria. The anatomical position was assessed by flexible FOB and evaluated based on fiber-optic scoring system. RESULTS: In the present study, demographic characteristics, vital parameters, Mallampati score, and Wilson's score were comparable in both the groups (P > 0.05). The fiber-optic score (FOS) 1 in Group II was 78.18% compared to 60% in Group I, but the difference was statistically not significant (P > 0.05). Furthermore, the mean FOS in Group II was slightly high (3.84 ± 0.87) compared to Group II (1.62 ± 0.87), but the difference was statistically not significant (P > 0.05). Further hemodynamic parameters (P > 0.05) and complications (P > 0.05) were comparable in both the groups. CONCLUSION: The LMA placement scoring was similar in both blind and direct laryngoscopic techniques. Blind insertion technique is a simpler, easier, and has stood the test of time. |
format | Online Article Text |
id | pubmed-5490140 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-54901402017-06-29 ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques Patil, Pooja Chandrakanth Chikkapillappa, Manjunath Abloodu Pujara, Vinayak Seenappa Anandswamy, Tejesh Channasandra Parate, Leena Harshad Bevinaguddaiah, Yatish Anesth Essays Res Original Article BACKGROUND AND OBJECTIVES: The laryngeal mask airway (LMA) ProSeal is most commonly used supraglottic airway device; it is routinely inserted by blind technique. Although blind insertion technique is most widely used, there are many techniques which are available such as priming the drain tube with a guiding instrument such as a suction catheter, a gum elastic bougie, a Flexi-Slip Stylet, direct laryngoscopy, and even a fiber-optic bronchoscope (FOB). The present study was undertaken to compare and assess the placement of LMA ProSeal using blind versus direct laryngoscopy techniques using FOB. MATERIALS AND METHODS: A prospective randomized comparative study of 110 patients divided into two groups of 55 each as Group I (blind insertion) and Group II (direct laryngoscopic insertion) after satisfying the inclusion criteria. The anatomical position was assessed by flexible FOB and evaluated based on fiber-optic scoring system. RESULTS: In the present study, demographic characteristics, vital parameters, Mallampati score, and Wilson's score were comparable in both the groups (P > 0.05). The fiber-optic score (FOS) 1 in Group II was 78.18% compared to 60% in Group I, but the difference was statistically not significant (P > 0.05). Furthermore, the mean FOS in Group II was slightly high (3.84 ± 0.87) compared to Group II (1.62 ± 0.87), but the difference was statistically not significant (P > 0.05). Further hemodynamic parameters (P > 0.05) and complications (P > 0.05) were comparable in both the groups. CONCLUSION: The LMA placement scoring was similar in both blind and direct laryngoscopic techniques. Blind insertion technique is a simpler, easier, and has stood the test of time. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5490140/ /pubmed/28663626 http://dx.doi.org/10.4103/0259-1162.206274 Text en Copyright: © 2017 Anesthesia: Essays and Researches http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Patil, Pooja Chandrakanth Chikkapillappa, Manjunath Abloodu Pujara, Vinayak Seenappa Anandswamy, Tejesh Channasandra Parate, Leena Harshad Bevinaguddaiah, Yatish ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques |
title | ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques |
title_full | ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques |
title_fullStr | ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques |
title_full_unstemmed | ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques |
title_short | ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques |
title_sort | proseal laryngeal mask airway placement: a comparison of blind versus direct laryngoscopic insertion techniques |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5490140/ https://www.ncbi.nlm.nih.gov/pubmed/28663626 http://dx.doi.org/10.4103/0259-1162.206274 |
work_keys_str_mv | AT patilpoojachandrakanth proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques AT chikkapillappamanjunathabloodu proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques AT pujaravinayakseenappa proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques AT anandswamytejeshchannasandra proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques AT parateleenaharshad proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques AT bevinaguddaiahyatish proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques |