Cargando…

ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques

BACKGROUND AND OBJECTIVES: The laryngeal mask airway (LMA) ProSeal is most commonly used supraglottic airway device; it is routinely inserted by blind technique. Although blind insertion technique is most widely used, there are many techniques which are available such as priming the drain tube with...

Descripción completa

Detalles Bibliográficos
Autores principales: Patil, Pooja Chandrakanth, Chikkapillappa, Manjunath Abloodu, Pujara, Vinayak Seenappa, Anandswamy, Tejesh Channasandra, Parate, Leena Harshad, Bevinaguddaiah, Yatish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5490140/
https://www.ncbi.nlm.nih.gov/pubmed/28663626
http://dx.doi.org/10.4103/0259-1162.206274
_version_ 1783246925319897088
author Patil, Pooja Chandrakanth
Chikkapillappa, Manjunath Abloodu
Pujara, Vinayak Seenappa
Anandswamy, Tejesh Channasandra
Parate, Leena Harshad
Bevinaguddaiah, Yatish
author_facet Patil, Pooja Chandrakanth
Chikkapillappa, Manjunath Abloodu
Pujara, Vinayak Seenappa
Anandswamy, Tejesh Channasandra
Parate, Leena Harshad
Bevinaguddaiah, Yatish
author_sort Patil, Pooja Chandrakanth
collection PubMed
description BACKGROUND AND OBJECTIVES: The laryngeal mask airway (LMA) ProSeal is most commonly used supraglottic airway device; it is routinely inserted by blind technique. Although blind insertion technique is most widely used, there are many techniques which are available such as priming the drain tube with a guiding instrument such as a suction catheter, a gum elastic bougie, a Flexi-Slip Stylet, direct laryngoscopy, and even a fiber-optic bronchoscope (FOB). The present study was undertaken to compare and assess the placement of LMA ProSeal using blind versus direct laryngoscopy techniques using FOB. MATERIALS AND METHODS: A prospective randomized comparative study of 110 patients divided into two groups of 55 each as Group I (blind insertion) and Group II (direct laryngoscopic insertion) after satisfying the inclusion criteria. The anatomical position was assessed by flexible FOB and evaluated based on fiber-optic scoring system. RESULTS: In the present study, demographic characteristics, vital parameters, Mallampati score, and Wilson's score were comparable in both the groups (P > 0.05). The fiber-optic score (FOS) 1 in Group II was 78.18% compared to 60% in Group I, but the difference was statistically not significant (P > 0.05). Furthermore, the mean FOS in Group II was slightly high (3.84 ± 0.87) compared to Group II (1.62 ± 0.87), but the difference was statistically not significant (P > 0.05). Further hemodynamic parameters (P > 0.05) and complications (P > 0.05) were comparable in both the groups. CONCLUSION: The LMA placement scoring was similar in both blind and direct laryngoscopic techniques. Blind insertion technique is a simpler, easier, and has stood the test of time.
format Online
Article
Text
id pubmed-5490140
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-54901402017-06-29 ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques Patil, Pooja Chandrakanth Chikkapillappa, Manjunath Abloodu Pujara, Vinayak Seenappa Anandswamy, Tejesh Channasandra Parate, Leena Harshad Bevinaguddaiah, Yatish Anesth Essays Res Original Article BACKGROUND AND OBJECTIVES: The laryngeal mask airway (LMA) ProSeal is most commonly used supraglottic airway device; it is routinely inserted by blind technique. Although blind insertion technique is most widely used, there are many techniques which are available such as priming the drain tube with a guiding instrument such as a suction catheter, a gum elastic bougie, a Flexi-Slip Stylet, direct laryngoscopy, and even a fiber-optic bronchoscope (FOB). The present study was undertaken to compare and assess the placement of LMA ProSeal using blind versus direct laryngoscopy techniques using FOB. MATERIALS AND METHODS: A prospective randomized comparative study of 110 patients divided into two groups of 55 each as Group I (blind insertion) and Group II (direct laryngoscopic insertion) after satisfying the inclusion criteria. The anatomical position was assessed by flexible FOB and evaluated based on fiber-optic scoring system. RESULTS: In the present study, demographic characteristics, vital parameters, Mallampati score, and Wilson's score were comparable in both the groups (P > 0.05). The fiber-optic score (FOS) 1 in Group II was 78.18% compared to 60% in Group I, but the difference was statistically not significant (P > 0.05). Furthermore, the mean FOS in Group II was slightly high (3.84 ± 0.87) compared to Group II (1.62 ± 0.87), but the difference was statistically not significant (P > 0.05). Further hemodynamic parameters (P > 0.05) and complications (P > 0.05) were comparable in both the groups. CONCLUSION: The LMA placement scoring was similar in both blind and direct laryngoscopic techniques. Blind insertion technique is a simpler, easier, and has stood the test of time. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5490140/ /pubmed/28663626 http://dx.doi.org/10.4103/0259-1162.206274 Text en Copyright: © 2017 Anesthesia: Essays and Researches http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Patil, Pooja Chandrakanth
Chikkapillappa, Manjunath Abloodu
Pujara, Vinayak Seenappa
Anandswamy, Tejesh Channasandra
Parate, Leena Harshad
Bevinaguddaiah, Yatish
ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques
title ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques
title_full ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques
title_fullStr ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques
title_full_unstemmed ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques
title_short ProSeal Laryngeal Mask Airway Placement: A Comparison of Blind versus Direct Laryngoscopic Insertion Techniques
title_sort proseal laryngeal mask airway placement: a comparison of blind versus direct laryngoscopic insertion techniques
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5490140/
https://www.ncbi.nlm.nih.gov/pubmed/28663626
http://dx.doi.org/10.4103/0259-1162.206274
work_keys_str_mv AT patilpoojachandrakanth proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques
AT chikkapillappamanjunathabloodu proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques
AT pujaravinayakseenappa proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques
AT anandswamytejeshchannasandra proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques
AT parateleenaharshad proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques
AT bevinaguddaiahyatish proseallaryngealmaskairwayplacementacomparisonofblindversusdirectlaryngoscopicinsertiontechniques