Cargando…

Thermal Characterization of Dynamic Silicon Cantilever Array Sensors by Digital Holographic Microscopy

In this paper, we apply a digital holographic microscope (DHM) in conjunction with stroboscopic acquisition synchronization. Here, the temperature-dependent decrease of the first resonance frequency (S(1)(T)) and Young’s elastic modulus (E(1)(T)) of silicon micromechanical cantilever sensors (MCSs)...

Descripción completa

Detalles Bibliográficos
Autores principales: Zakerin, Marjan, Novak, Antonin, Toda, Masaya, Emery, Yves, Natalio, Filipe, Butt, Hans-Jürgen, Berger, Rüdiger
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5490691/
https://www.ncbi.nlm.nih.gov/pubmed/28545236
http://dx.doi.org/10.3390/s17061191
_version_ 1783247036152283136
author Zakerin, Marjan
Novak, Antonin
Toda, Masaya
Emery, Yves
Natalio, Filipe
Butt, Hans-Jürgen
Berger, Rüdiger
author_facet Zakerin, Marjan
Novak, Antonin
Toda, Masaya
Emery, Yves
Natalio, Filipe
Butt, Hans-Jürgen
Berger, Rüdiger
author_sort Zakerin, Marjan
collection PubMed
description In this paper, we apply a digital holographic microscope (DHM) in conjunction with stroboscopic acquisition synchronization. Here, the temperature-dependent decrease of the first resonance frequency (S(1)(T)) and Young’s elastic modulus (E(1)(T)) of silicon micromechanical cantilever sensors (MCSs) are measured. To perform these measurements, the MCSs are uniformly heated from T(0) = 298 K to T = 450 K while being externally actuated with a piezo-actuator in a certain frequency range close to their first resonance frequencies. At each temperature, the DHM records the time-sequence of the 3D topographies for the given frequency range. Such holographic data allow for the extracting of the out-of-plane vibrations at any relevant area of the MCSs. Next, the Bode and Nyquist diagrams are used to determine the resonant frequencies with a precision of 0.1 Hz. Our results show that the decrease of resonance frequency is a direct consequence of the reduction of the silicon elastic modulus upon heating. The measured temperature dependence of the Young’s modulus is in very good accordance with the previously-reported values, validating the reliability and applicability of this method for micromechanical sensing applications.
format Online
Article
Text
id pubmed-5490691
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-54906912017-07-03 Thermal Characterization of Dynamic Silicon Cantilever Array Sensors by Digital Holographic Microscopy Zakerin, Marjan Novak, Antonin Toda, Masaya Emery, Yves Natalio, Filipe Butt, Hans-Jürgen Berger, Rüdiger Sensors (Basel) Article In this paper, we apply a digital holographic microscope (DHM) in conjunction with stroboscopic acquisition synchronization. Here, the temperature-dependent decrease of the first resonance frequency (S(1)(T)) and Young’s elastic modulus (E(1)(T)) of silicon micromechanical cantilever sensors (MCSs) are measured. To perform these measurements, the MCSs are uniformly heated from T(0) = 298 K to T = 450 K while being externally actuated with a piezo-actuator in a certain frequency range close to their first resonance frequencies. At each temperature, the DHM records the time-sequence of the 3D topographies for the given frequency range. Such holographic data allow for the extracting of the out-of-plane vibrations at any relevant area of the MCSs. Next, the Bode and Nyquist diagrams are used to determine the resonant frequencies with a precision of 0.1 Hz. Our results show that the decrease of resonance frequency is a direct consequence of the reduction of the silicon elastic modulus upon heating. The measured temperature dependence of the Young’s modulus is in very good accordance with the previously-reported values, validating the reliability and applicability of this method for micromechanical sensing applications. MDPI 2017-05-23 /pmc/articles/PMC5490691/ /pubmed/28545236 http://dx.doi.org/10.3390/s17061191 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zakerin, Marjan
Novak, Antonin
Toda, Masaya
Emery, Yves
Natalio, Filipe
Butt, Hans-Jürgen
Berger, Rüdiger
Thermal Characterization of Dynamic Silicon Cantilever Array Sensors by Digital Holographic Microscopy
title Thermal Characterization of Dynamic Silicon Cantilever Array Sensors by Digital Holographic Microscopy
title_full Thermal Characterization of Dynamic Silicon Cantilever Array Sensors by Digital Holographic Microscopy
title_fullStr Thermal Characterization of Dynamic Silicon Cantilever Array Sensors by Digital Holographic Microscopy
title_full_unstemmed Thermal Characterization of Dynamic Silicon Cantilever Array Sensors by Digital Holographic Microscopy
title_short Thermal Characterization of Dynamic Silicon Cantilever Array Sensors by Digital Holographic Microscopy
title_sort thermal characterization of dynamic silicon cantilever array sensors by digital holographic microscopy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5490691/
https://www.ncbi.nlm.nih.gov/pubmed/28545236
http://dx.doi.org/10.3390/s17061191
work_keys_str_mv AT zakerinmarjan thermalcharacterizationofdynamicsiliconcantileverarraysensorsbydigitalholographicmicroscopy
AT novakantonin thermalcharacterizationofdynamicsiliconcantileverarraysensorsbydigitalholographicmicroscopy
AT todamasaya thermalcharacterizationofdynamicsiliconcantileverarraysensorsbydigitalholographicmicroscopy
AT emeryyves thermalcharacterizationofdynamicsiliconcantileverarraysensorsbydigitalholographicmicroscopy
AT nataliofilipe thermalcharacterizationofdynamicsiliconcantileverarraysensorsbydigitalholographicmicroscopy
AT butthansjurgen thermalcharacterizationofdynamicsiliconcantileverarraysensorsbydigitalholographicmicroscopy
AT bergerrudiger thermalcharacterizationofdynamicsiliconcantileverarraysensorsbydigitalholographicmicroscopy