Cargando…
Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms
In this work, we developed a device capable to generate a non-thermal plasma discharge inside a sealed bag. The aim of this study was to assess the effectiveness of the oxygen, nitrogen and argon plasma sterilization on Pseudomonas aeruginosa, Staphylococcus aureus and Bacillus subtilis spores accor...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5491144/ https://www.ncbi.nlm.nih.gov/pubmed/28662202 http://dx.doi.org/10.1371/journal.pone.0180183 |
_version_ | 1783247090834472960 |
---|---|
author | Ben Belgacem, Zouhaier Carré, Gaëlle Charpentier, Emilie Le-Bras, Florian Maho, Thomas Robert, Eric Pouvesle, Jean-Michel Polidor, Franck Gangloff, Sophie C. Boudifa, Mohamed Gelle, Marie-Paule |
author_facet | Ben Belgacem, Zouhaier Carré, Gaëlle Charpentier, Emilie Le-Bras, Florian Maho, Thomas Robert, Eric Pouvesle, Jean-Michel Polidor, Franck Gangloff, Sophie C. Boudifa, Mohamed Gelle, Marie-Paule |
author_sort | Ben Belgacem, Zouhaier |
collection | PubMed |
description | In this work, we developed a device capable to generate a non-thermal plasma discharge inside a sealed bag. The aim of this study was to assess the effectiveness of the oxygen, nitrogen and argon plasma sterilization on Pseudomonas aeruginosa, Staphylococcus aureus and Bacillus subtilis spores according to the NF EN 556 Norm. Moreover the bag integrity which is a critical key to maintain the sterile state of items after the end of the process was verified by Fourier Transform Infrared (FTIR) and X-ray Photoelectron Spectrometry (XPS) analyses. After plasma treatments, the bacterial counting showed a 6 log reduction of P. aeruginosa and S. aureus in 45 min and 120 min respectively whatever the gas used and a 4 log reduction of B. subtilis spores in 120 min with only oxygen plasma. These results were confirmed by Scanning Electron Microscopy (SEM) observations showing altered bacteria or spores and numerous debris. Taking into account the studied microorganisms, the oxygen plasma treatment showed the highest efficiency. FTIR and XPS analyses showed that this treatment induced no significant modification of the bags. To conclude this non-thermal plasma sterilization technique could be an opportunity to sterilize heat and chemical-sensitive medical devices and to preserve their sterile state after the end of the process. |
format | Online Article Text |
id | pubmed-5491144 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-54911442017-07-18 Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms Ben Belgacem, Zouhaier Carré, Gaëlle Charpentier, Emilie Le-Bras, Florian Maho, Thomas Robert, Eric Pouvesle, Jean-Michel Polidor, Franck Gangloff, Sophie C. Boudifa, Mohamed Gelle, Marie-Paule PLoS One Research Article In this work, we developed a device capable to generate a non-thermal plasma discharge inside a sealed bag. The aim of this study was to assess the effectiveness of the oxygen, nitrogen and argon plasma sterilization on Pseudomonas aeruginosa, Staphylococcus aureus and Bacillus subtilis spores according to the NF EN 556 Norm. Moreover the bag integrity which is a critical key to maintain the sterile state of items after the end of the process was verified by Fourier Transform Infrared (FTIR) and X-ray Photoelectron Spectrometry (XPS) analyses. After plasma treatments, the bacterial counting showed a 6 log reduction of P. aeruginosa and S. aureus in 45 min and 120 min respectively whatever the gas used and a 4 log reduction of B. subtilis spores in 120 min with only oxygen plasma. These results were confirmed by Scanning Electron Microscopy (SEM) observations showing altered bacteria or spores and numerous debris. Taking into account the studied microorganisms, the oxygen plasma treatment showed the highest efficiency. FTIR and XPS analyses showed that this treatment induced no significant modification of the bags. To conclude this non-thermal plasma sterilization technique could be an opportunity to sterilize heat and chemical-sensitive medical devices and to preserve their sterile state after the end of the process. Public Library of Science 2017-06-29 /pmc/articles/PMC5491144/ /pubmed/28662202 http://dx.doi.org/10.1371/journal.pone.0180183 Text en © 2017 Ben Belgacem et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Ben Belgacem, Zouhaier Carré, Gaëlle Charpentier, Emilie Le-Bras, Florian Maho, Thomas Robert, Eric Pouvesle, Jean-Michel Polidor, Franck Gangloff, Sophie C. Boudifa, Mohamed Gelle, Marie-Paule Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms |
title | Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms |
title_full | Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms |
title_fullStr | Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms |
title_full_unstemmed | Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms |
title_short | Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms |
title_sort | innovative non-thermal plasma disinfection process inside sealed bags: assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5491144/ https://www.ncbi.nlm.nih.gov/pubmed/28662202 http://dx.doi.org/10.1371/journal.pone.0180183 |
work_keys_str_mv | AT benbelgacemzouhaier innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT carregaelle innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT charpentieremilie innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT lebrasflorian innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT mahothomas innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT roberteric innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT pouveslejeanmichel innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT polidorfranck innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT gangloffsophiec innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT boudifamohamed innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms AT gellemariepaule innovativenonthermalplasmadisinfectionprocessinsidesealedbagsassessmentofbactericidalandsporicidaleffectivenessinregardtocurrentsterilizationnorms |