Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols

BACKGROUND: ECG-gated cardiac computed tomography angiography (CCTA) has found widespread use for prosthesis sizing before transcatheter aortic valve implantation (TAVI). However, still little data exists on the optimal scan-strategy in such patients. We hypothesized that prospectively triggered CCT...

Descripción completa

Detalles Bibliográficos
Autores principales: Hofmann, Nina P., Schuetz, Moritz, Bekeredjian, Raffi, Pleger, Sven, Chorianopoulos, Emanuel, Giusca, Sorin, André, Florian, Gitsioudis, Gitsios, Schlett, Christopher, Kauczor, Hans-Ulrich, Katus, Hugo A., Korosoglou, Grigorios
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5491755/
https://www.ncbi.nlm.nih.gov/pubmed/28702479
http://dx.doi.org/10.1016/j.ejro.2017.06.001
_version_ 1783247195342897152
author Hofmann, Nina P.
Schuetz, Moritz
Bekeredjian, Raffi
Pleger, Sven
Chorianopoulos, Emanuel
Giusca, Sorin
André, Florian
Gitsioudis, Gitsios
Schlett, Christopher
Kauczor, Hans-Ulrich
Katus, Hugo A.
Korosoglou, Grigorios
author_facet Hofmann, Nina P.
Schuetz, Moritz
Bekeredjian, Raffi
Pleger, Sven
Chorianopoulos, Emanuel
Giusca, Sorin
André, Florian
Gitsioudis, Gitsios
Schlett, Christopher
Kauczor, Hans-Ulrich
Katus, Hugo A.
Korosoglou, Grigorios
author_sort Hofmann, Nina P.
collection PubMed
description BACKGROUND: ECG-gated cardiac computed tomography angiography (CCTA) has found widespread use for prosthesis sizing before transcatheter aortic valve implantation (TAVI). However, still little data exists on the optimal scan-strategy in such patients. We hypothesized that prospectively triggered CCTA can enable the visualization of aortic valve structures and peripheral arteries with lower radiation and contrast agent exposure in patients considered for TAVI compared to retrospectively gated protocols. METHODS: All studies were performed using a 256 multi-detector single source CT (iCT Philips, Best, Netherlands). With the prospective protocol the whole volume from the heart to the iliofemoral arteries scanned using prospective triggering. With the retrospective protocol a first retrospectively gated scan was performed for the heart and the iliofemoral part was subsequently scanned using a second non-triggered scan. Image quality was assessed semi-quantitatively and signal-to-noise- (SNR) and contrast-to-noise-ratios (CNR) were obtained for all scans. RESULTS: Prospective CCTA was performed in 74 and in 34 patients, respectively using non-tailored and BMI adapted scans, whereas retrospective CCTA was performed in 57 patients. Prospective scans required lower contrast agent administration compared to retrospective scans (71 ± 8 mL versus 91 ± 15 mL, p < 0.01) and resulted in lower radiation exposure (26 ± 7mSv for retrospective versus 15 ± 3mSv for non-tailored prospective versus 8 ± 4mSv for BMI-adapted prospective scans, p < 0.01). Visual image quality was better for the evaluation of aortic valve structures and similar for the assessment of iliofemoral anatomy with prospective versus retrospective scans. In addition, contrast density, SNR and CNR were higher in the ascending aorta with prospective versus retrospective CCTA (434 ± 98HU versus 349 ± 112HU; 35 ± 14 versus 24 ± 9 and 31 ± 11 versus 16 ± 7, p < 0.001 for all). Subsection analysis by heart rate groups demonstrated that both image quality and CNR were significantly higher in patients with prospective versus retrospective CCTA, irrespective of the heart rate during image acquisition. CONCLUSION: Prospectively triggered CCTA allows for improved visualization of aortic valve structures and peripheral arteries in patients scheduled for TAVI with simultaneously reduced contrast agent dose and radiation exposure. Therefore, this acquisition mode seems to be the preferred for the evaluation of patients considered for TAVI.
format Online
Article
Text
id pubmed-5491755
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-54917552017-07-12 Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols Hofmann, Nina P. Schuetz, Moritz Bekeredjian, Raffi Pleger, Sven Chorianopoulos, Emanuel Giusca, Sorin André, Florian Gitsioudis, Gitsios Schlett, Christopher Kauczor, Hans-Ulrich Katus, Hugo A. Korosoglou, Grigorios Eur J Radiol Open Article BACKGROUND: ECG-gated cardiac computed tomography angiography (CCTA) has found widespread use for prosthesis sizing before transcatheter aortic valve implantation (TAVI). However, still little data exists on the optimal scan-strategy in such patients. We hypothesized that prospectively triggered CCTA can enable the visualization of aortic valve structures and peripheral arteries with lower radiation and contrast agent exposure in patients considered for TAVI compared to retrospectively gated protocols. METHODS: All studies were performed using a 256 multi-detector single source CT (iCT Philips, Best, Netherlands). With the prospective protocol the whole volume from the heart to the iliofemoral arteries scanned using prospective triggering. With the retrospective protocol a first retrospectively gated scan was performed for the heart and the iliofemoral part was subsequently scanned using a second non-triggered scan. Image quality was assessed semi-quantitatively and signal-to-noise- (SNR) and contrast-to-noise-ratios (CNR) were obtained for all scans. RESULTS: Prospective CCTA was performed in 74 and in 34 patients, respectively using non-tailored and BMI adapted scans, whereas retrospective CCTA was performed in 57 patients. Prospective scans required lower contrast agent administration compared to retrospective scans (71 ± 8 mL versus 91 ± 15 mL, p < 0.01) and resulted in lower radiation exposure (26 ± 7mSv for retrospective versus 15 ± 3mSv for non-tailored prospective versus 8 ± 4mSv for BMI-adapted prospective scans, p < 0.01). Visual image quality was better for the evaluation of aortic valve structures and similar for the assessment of iliofemoral anatomy with prospective versus retrospective scans. In addition, contrast density, SNR and CNR were higher in the ascending aorta with prospective versus retrospective CCTA (434 ± 98HU versus 349 ± 112HU; 35 ± 14 versus 24 ± 9 and 31 ± 11 versus 16 ± 7, p < 0.001 for all). Subsection analysis by heart rate groups demonstrated that both image quality and CNR were significantly higher in patients with prospective versus retrospective CCTA, irrespective of the heart rate during image acquisition. CONCLUSION: Prospectively triggered CCTA allows for improved visualization of aortic valve structures and peripheral arteries in patients scheduled for TAVI with simultaneously reduced contrast agent dose and radiation exposure. Therefore, this acquisition mode seems to be the preferred for the evaluation of patients considered for TAVI. Elsevier 2017-06-26 /pmc/articles/PMC5491755/ /pubmed/28702479 http://dx.doi.org/10.1016/j.ejro.2017.06.001 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Hofmann, Nina P.
Schuetz, Moritz
Bekeredjian, Raffi
Pleger, Sven
Chorianopoulos, Emanuel
Giusca, Sorin
André, Florian
Gitsioudis, Gitsios
Schlett, Christopher
Kauczor, Hans-Ulrich
Katus, Hugo A.
Korosoglou, Grigorios
Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols
title Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols
title_full Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols
title_fullStr Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols
title_full_unstemmed Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols
title_short Image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols
title_sort image quality and contrast agent exposure in cardiac computed tomography angiography prior to transcatheter aortic valve implantation procedures using different acquisition protocols
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5491755/
https://www.ncbi.nlm.nih.gov/pubmed/28702479
http://dx.doi.org/10.1016/j.ejro.2017.06.001
work_keys_str_mv AT hofmannninap imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT schuetzmoritz imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT bekeredjianraffi imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT plegersven imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT chorianopoulosemanuel imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT giuscasorin imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT andreflorian imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT gitsioudisgitsios imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT schlettchristopher imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT kauczorhansulrich imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT katushugoa imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols
AT korosoglougrigorios imagequalityandcontrastagentexposureincardiaccomputedtomographyangiographypriortotranscatheteraorticvalveimplantationproceduresusingdifferentacquisitionprotocols