Air Flow Detection in Crude Oil by Infrared Light
In this paper, we used infrared light in the range of 8–12 μm to develop and test an optical imaging system to detect air bubbles flowing in oil. The system basically comprises a broadband light source and a 31 × 32 thermopile array to generate images. To analyze the effects related to light absorpt...