Cargando…

Liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - An institutional experience

BACKGROUND: Liquid-based cytology (LBC) has been developed as an alternative for conventional cytology (CC) in cervical smears. It is now increasingly being used all over the world for cervical cancer screening. However, its role and diagnostic accuracy in bronchial wash (BW)/bronchoalveolar lavage...

Descripción completa

Detalles Bibliográficos
Autores principales: Thakur, Abha, Bakshi, Pooja, Kaur, Gagandeep, Verma, Kusum
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5492748/
https://www.ncbi.nlm.nih.gov/pubmed/28701824
http://dx.doi.org/10.4103/JOC.JOC_7_16
_version_ 1783247392758300672
author Thakur, Abha
Bakshi, Pooja
Kaur, Gagandeep
Verma, Kusum
author_facet Thakur, Abha
Bakshi, Pooja
Kaur, Gagandeep
Verma, Kusum
author_sort Thakur, Abha
collection PubMed
description BACKGROUND: Liquid-based cytology (LBC) has been developed as an alternative for conventional cytology (CC) in cervical smears. It is now increasingly being used all over the world for cervical cancer screening. However, its role and diagnostic accuracy in bronchial wash (BW)/bronchoalveolar lavage (BAL) specimens remains undetermined. AIMS: To assess and compare the diagnostic performance and accuracy of LBC with CC for detecting malignancy in bronchial specimens. SETTINGS AND DESIGN: This was a retrospective analytical hospital-based study. MATERIALS AND METHODS: Bronchial specimens (BW/BAL) received over a period of 4.5 years were reviewed. The samples were processed by CC from June 2010 to September 2012 (2.25 years) and by LBC from October 2012 to December 2014 (2.25 years). Data were retrieved from the records of cytology laboratory and compared among both the groups. Detection rate for histologically or cytologically verified samples was calculated. RESULTS: A total of 559 cases verified by histological and cytological follow-up were evaluated. These included 247 CC cases and 312 LBC cases. The positive diagnostic rate for malignancy in CC was 28.6% whereas that for LBC was 32.9%. The negative diagnostic rates were 66.5% and 66.3% for CC and LBC, respectively. However, unsatisfactory rates had shown a good reduction from 4.4% in CC to 0.6% after LBC introduction. The smears showed more homogeneous distribution of cells with elimination of obscuring factors such as blood, inflammation, and mucus. CONCLUSIONS: The diagnostic accuracy of LBC was slightly better than CC. The unsatisfactory rates showed reduction in LBC preparation. Thus, LBC is a viable alternative to CC and has the advantages of standardization of preparation with decrease in unsatisfactory rates.
format Online
Article
Text
id pubmed-5492748
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-54927482017-07-13 Liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - An institutional experience Thakur, Abha Bakshi, Pooja Kaur, Gagandeep Verma, Kusum J Cytol Original Article BACKGROUND: Liquid-based cytology (LBC) has been developed as an alternative for conventional cytology (CC) in cervical smears. It is now increasingly being used all over the world for cervical cancer screening. However, its role and diagnostic accuracy in bronchial wash (BW)/bronchoalveolar lavage (BAL) specimens remains undetermined. AIMS: To assess and compare the diagnostic performance and accuracy of LBC with CC for detecting malignancy in bronchial specimens. SETTINGS AND DESIGN: This was a retrospective analytical hospital-based study. MATERIALS AND METHODS: Bronchial specimens (BW/BAL) received over a period of 4.5 years were reviewed. The samples were processed by CC from June 2010 to September 2012 (2.25 years) and by LBC from October 2012 to December 2014 (2.25 years). Data were retrieved from the records of cytology laboratory and compared among both the groups. Detection rate for histologically or cytologically verified samples was calculated. RESULTS: A total of 559 cases verified by histological and cytological follow-up were evaluated. These included 247 CC cases and 312 LBC cases. The positive diagnostic rate for malignancy in CC was 28.6% whereas that for LBC was 32.9%. The negative diagnostic rates were 66.5% and 66.3% for CC and LBC, respectively. However, unsatisfactory rates had shown a good reduction from 4.4% in CC to 0.6% after LBC introduction. The smears showed more homogeneous distribution of cells with elimination of obscuring factors such as blood, inflammation, and mucus. CONCLUSIONS: The diagnostic accuracy of LBC was slightly better than CC. The unsatisfactory rates showed reduction in LBC preparation. Thus, LBC is a viable alternative to CC and has the advantages of standardization of preparation with decrease in unsatisfactory rates. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5492748/ /pubmed/28701824 http://dx.doi.org/10.4103/JOC.JOC_7_16 Text en Copyright: © 2017 Journal of Cytology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Thakur, Abha
Bakshi, Pooja
Kaur, Gagandeep
Verma, Kusum
Liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - An institutional experience
title Liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - An institutional experience
title_full Liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - An institutional experience
title_fullStr Liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - An institutional experience
title_full_unstemmed Liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - An institutional experience
title_short Liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - An institutional experience
title_sort liquid-based and conventional cytology for bronchial washings/bronchoalveolar lavages in the diagnosis of malignancy - an institutional experience
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5492748/
https://www.ncbi.nlm.nih.gov/pubmed/28701824
http://dx.doi.org/10.4103/JOC.JOC_7_16
work_keys_str_mv AT thakurabha liquidbasedandconventionalcytologyforbronchialwashingsbronchoalveolarlavagesinthediagnosisofmalignancyaninstitutionalexperience
AT bakshipooja liquidbasedandconventionalcytologyforbronchialwashingsbronchoalveolarlavagesinthediagnosisofmalignancyaninstitutionalexperience
AT kaurgagandeep liquidbasedandconventionalcytologyforbronchialwashingsbronchoalveolarlavagesinthediagnosisofmalignancyaninstitutionalexperience
AT vermakusum liquidbasedandconventionalcytologyforbronchialwashingsbronchoalveolarlavagesinthediagnosisofmalignancyaninstitutionalexperience