Cargando…
Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis
In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP) and a locking compression plate (LCP)...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494084/ https://www.ncbi.nlm.nih.gov/pubmed/29065654 http://dx.doi.org/10.1155/2017/8590251 |
_version_ | 1783247614334992384 |
---|---|
author | Zhou, Jiang-Jun Zhao, Min Liu, Da Liu, Hai-Ying Du, Cheng-Fei |
author_facet | Zhou, Jiang-Jun Zhao, Min Liu, Da Liu, Hai-Ying Du, Cheng-Fei |
author_sort | Zhou, Jiang-Jun |
collection | PubMed |
description | In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP) and a locking compression plate (LCP). CT data of a male volunteer was converted to middle femoral comminuted fracture finite element analysis model. The fracture was fixated by NALCP and LCP. Stress distributions were observed. Under slow walking load and torsion load, the stress distribution tendency of the two plates was roughly uniform. The anterolateral femur was the tension stress area, and the bone block shifted toward the anterolateral femur. Maximum stress was found on the lateral border of the number 5 countersink of the plate. Under a slow walking load, the NALCP maximum stress was 2.160e+03 MPa and the LCP was 8.561e+02 MPa. Under torsion load, the NALCP maximum stress was 2.260e+03 MPa and the LCP was 6.813e+02 MPa. Based on those results of finite element analysis, the NALCP can provide adequate mechanical stability for comminuted fractures, which would help fixate the bone block and promote bone healing. |
format | Online Article Text |
id | pubmed-5494084 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-54940842017-07-12 Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis Zhou, Jiang-Jun Zhao, Min Liu, Da Liu, Hai-Ying Du, Cheng-Fei J Healthc Eng Research Article In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP) and a locking compression plate (LCP). CT data of a male volunteer was converted to middle femoral comminuted fracture finite element analysis model. The fracture was fixated by NALCP and LCP. Stress distributions were observed. Under slow walking load and torsion load, the stress distribution tendency of the two plates was roughly uniform. The anterolateral femur was the tension stress area, and the bone block shifted toward the anterolateral femur. Maximum stress was found on the lateral border of the number 5 countersink of the plate. Under a slow walking load, the NALCP maximum stress was 2.160e+03 MPa and the LCP was 8.561e+02 MPa. Under torsion load, the NALCP maximum stress was 2.260e+03 MPa and the LCP was 6.813e+02 MPa. Based on those results of finite element analysis, the NALCP can provide adequate mechanical stability for comminuted fractures, which would help fixate the bone block and promote bone healing. Hindawi 2017 2017-06-18 /pmc/articles/PMC5494084/ /pubmed/29065654 http://dx.doi.org/10.1155/2017/8590251 Text en Copyright © 2017 Jiang-Jun Zhou et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhou, Jiang-Jun Zhao, Min Liu, Da Liu, Hai-Ying Du, Cheng-Fei Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis |
title | Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis |
title_full | Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis |
title_fullStr | Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis |
title_full_unstemmed | Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis |
title_short | Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis |
title_sort | biomechanical property of a newly designed assembly locking compression plate: three-dimensional finite element analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494084/ https://www.ncbi.nlm.nih.gov/pubmed/29065654 http://dx.doi.org/10.1155/2017/8590251 |
work_keys_str_mv | AT zhoujiangjun biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis AT zhaomin biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis AT liuda biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis AT liuhaiying biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis AT duchengfei biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis |