Cargando…

Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis

In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP) and a locking compression plate (LCP)...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Jiang-Jun, Zhao, Min, Liu, Da, Liu, Hai-Ying, Du, Cheng-Fei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494084/
https://www.ncbi.nlm.nih.gov/pubmed/29065654
http://dx.doi.org/10.1155/2017/8590251
_version_ 1783247614334992384
author Zhou, Jiang-Jun
Zhao, Min
Liu, Da
Liu, Hai-Ying
Du, Cheng-Fei
author_facet Zhou, Jiang-Jun
Zhao, Min
Liu, Da
Liu, Hai-Ying
Du, Cheng-Fei
author_sort Zhou, Jiang-Jun
collection PubMed
description In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP) and a locking compression plate (LCP). CT data of a male volunteer was converted to middle femoral comminuted fracture finite element analysis model. The fracture was fixated by NALCP and LCP. Stress distributions were observed. Under slow walking load and torsion load, the stress distribution tendency of the two plates was roughly uniform. The anterolateral femur was the tension stress area, and the bone block shifted toward the anterolateral femur. Maximum stress was found on the lateral border of the number 5 countersink of the plate. Under a slow walking load, the NALCP maximum stress was 2.160e+03 MPa and the LCP was 8.561e+02 MPa. Under torsion load, the NALCP maximum stress was 2.260e+03 MPa and the LCP was 6.813e+02 MPa. Based on those results of finite element analysis, the NALCP can provide adequate mechanical stability for comminuted fractures, which would help fixate the bone block and promote bone healing.
format Online
Article
Text
id pubmed-5494084
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-54940842017-07-12 Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis Zhou, Jiang-Jun Zhao, Min Liu, Da Liu, Hai-Ying Du, Cheng-Fei J Healthc Eng Research Article In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP) and a locking compression plate (LCP). CT data of a male volunteer was converted to middle femoral comminuted fracture finite element analysis model. The fracture was fixated by NALCP and LCP. Stress distributions were observed. Under slow walking load and torsion load, the stress distribution tendency of the two plates was roughly uniform. The anterolateral femur was the tension stress area, and the bone block shifted toward the anterolateral femur. Maximum stress was found on the lateral border of the number 5 countersink of the plate. Under a slow walking load, the NALCP maximum stress was 2.160e+03 MPa and the LCP was 8.561e+02 MPa. Under torsion load, the NALCP maximum stress was 2.260e+03 MPa and the LCP was 6.813e+02 MPa. Based on those results of finite element analysis, the NALCP can provide adequate mechanical stability for comminuted fractures, which would help fixate the bone block and promote bone healing. Hindawi 2017 2017-06-18 /pmc/articles/PMC5494084/ /pubmed/29065654 http://dx.doi.org/10.1155/2017/8590251 Text en Copyright © 2017 Jiang-Jun Zhou et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhou, Jiang-Jun
Zhao, Min
Liu, Da
Liu, Hai-Ying
Du, Cheng-Fei
Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis
title Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis
title_full Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis
title_fullStr Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis
title_full_unstemmed Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis
title_short Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis
title_sort biomechanical property of a newly designed assembly locking compression plate: three-dimensional finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494084/
https://www.ncbi.nlm.nih.gov/pubmed/29065654
http://dx.doi.org/10.1155/2017/8590251
work_keys_str_mv AT zhoujiangjun biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis
AT zhaomin biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis
AT liuda biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis
AT liuhaiying biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis
AT duchengfei biomechanicalpropertyofanewlydesignedassemblylockingcompressionplatethreedimensionalfiniteelementanalysis