Cargando…

Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae

PURPOSE: Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically s...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Jung-Yoo, Sim, Jae-Hyuk, Yeo, In-Sung Luke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Periodontology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494313/
https://www.ncbi.nlm.nih.gov/pubmed/28680714
http://dx.doi.org/10.5051/jpis.2017.47.3.182
_version_ 1783247654703071232
author Choi, Jung-Yoo
Sim, Jae-Hyuk
Yeo, In-Sung Luke
author_facet Choi, Jung-Yoo
Sim, Jae-Hyuk
Yeo, In-Sung Luke
author_sort Choi, Jung-Yoo
collection PubMed
description PURPOSE: Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically separate contact and distance osteogenesis, thus allowing contact osteogenesis to be measured in the absence of possible triggers from distance osteogenesis. METHODS: Sandblasted and acid-etched (SLA) and modified SLA (modSLA) implants were used. Both types had been sandblasted with large grit and then etched with acid. The modSLA implants then underwent additional treatment to increase hydrophilicity. The implants were implanted into rabbit tibiae, and half were implanted within Ti tubes. The bone-to-implant contact (BIC) ratio was calculated for each implant. Immunohistochemical analyses of bone morphogenetic protein (BMP)-2 expression and new bone formation (Masson trichrome stain) were performed. RESULTS: The implants outside of Ti tubes were associated with good bone formation along the implant surface. Implantation within a Ti tube significantly reduced the BIC ratio (P<0.001). Compared with the modSLA implants, the SLA implants were associated with significantly higher BIC ratios, regardless of the presence or absence of Ti tubes (P=0.043). In the absence of Ti tubes, the bone adjacent to the implant had areas of new bone formation that expressed BMP-2 at high levels. CONCLUSIONS: This study disproved the null hypothesis and suggested that contact osteogenesis is initiated by signals from the old bone that undergoes distance osteogenesis after drilling. This signal may be BMP-2.
format Online
Article
Text
id pubmed-5494313
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Korean Academy of Periodontology
record_format MEDLINE/PubMed
spelling pubmed-54943132017-07-05 Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae Choi, Jung-Yoo Sim, Jae-Hyuk Yeo, In-Sung Luke J Periodontal Implant Sci Research Article PURPOSE: Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically separate contact and distance osteogenesis, thus allowing contact osteogenesis to be measured in the absence of possible triggers from distance osteogenesis. METHODS: Sandblasted and acid-etched (SLA) and modified SLA (modSLA) implants were used. Both types had been sandblasted with large grit and then etched with acid. The modSLA implants then underwent additional treatment to increase hydrophilicity. The implants were implanted into rabbit tibiae, and half were implanted within Ti tubes. The bone-to-implant contact (BIC) ratio was calculated for each implant. Immunohistochemical analyses of bone morphogenetic protein (BMP)-2 expression and new bone formation (Masson trichrome stain) were performed. RESULTS: The implants outside of Ti tubes were associated with good bone formation along the implant surface. Implantation within a Ti tube significantly reduced the BIC ratio (P<0.001). Compared with the modSLA implants, the SLA implants were associated with significantly higher BIC ratios, regardless of the presence or absence of Ti tubes (P=0.043). In the absence of Ti tubes, the bone adjacent to the implant had areas of new bone formation that expressed BMP-2 at high levels. CONCLUSIONS: This study disproved the null hypothesis and suggested that contact osteogenesis is initiated by signals from the old bone that undergoes distance osteogenesis after drilling. This signal may be BMP-2. Korean Academy of Periodontology 2017-06 2017-06-28 /pmc/articles/PMC5494313/ /pubmed/28680714 http://dx.doi.org/10.5051/jpis.2017.47.3.182 Text en Copyright © 2017. Korean Academy of Periodontology https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/).
spellingShingle Research Article
Choi, Jung-Yoo
Sim, Jae-Hyuk
Yeo, In-Sung Luke
Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae
title Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae
title_full Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae
title_fullStr Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae
title_full_unstemmed Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae
title_short Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae
title_sort characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494313/
https://www.ncbi.nlm.nih.gov/pubmed/28680714
http://dx.doi.org/10.5051/jpis.2017.47.3.182
work_keys_str_mv AT choijungyoo characteristicsofcontactanddistanceosteogenesisaroundmodifiedimplantsurfacesinrabbittibiae
AT simjaehyuk characteristicsofcontactanddistanceosteogenesisaroundmodifiedimplantsurfacesinrabbittibiae
AT yeoinsungluke characteristicsofcontactanddistanceosteogenesisaroundmodifiedimplantsurfacesinrabbittibiae