Cargando…
Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography
We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494667/ https://www.ncbi.nlm.nih.gov/pubmed/28693244 http://dx.doi.org/10.3892/ol.2017.6245 |
_version_ | 1783247708837904384 |
---|---|
author | Liu, Mei-Juan Men, Yan-Ming Zhang, Yong-Lin Zhang, Yu-Xi Liu, Hao |
author_facet | Liu, Mei-Juan Men, Yan-Ming Zhang, Yong-Lin Zhang, Yu-Xi Liu, Hao |
author_sort | Liu, Mei-Juan |
collection | PubMed |
description | We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio <1, microcalcification and irregular peripheral echo halo, and there were statistically significant differences compared with the benign nodules (P<0.05). UE showed that the differences between benign and malignant nodules in 2, 3 and 4 points were statistically significant (P<0.05). The manifestations of malignant nodules in UC were mostly the irregular shape, obscure boundary, no obvious enhancement, heterogeneous enhancement and visible perfusion defects, and there were statistically significant differences compared with the benign nodules (P<0.05). ROC curve showed that both sensitivity and specificity of UE and UC were superior to those of conventional US. AUC was the largest (AUC = 0.908) and the diagnostic value was the highest in the conventional US combined with UE and UC. Conventional US combined with elastography and UC can significantly improve the sensitivity, specificity and accuracy of diagnosis of benign and malignant thyroid nodules. |
format | Online Article Text |
id | pubmed-5494667 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-54946672017-07-07 Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography Liu, Mei-Juan Men, Yan-Ming Zhang, Yong-Lin Zhang, Yu-Xi Liu, Hao Oncol Lett Articles We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio <1, microcalcification and irregular peripheral echo halo, and there were statistically significant differences compared with the benign nodules (P<0.05). UE showed that the differences between benign and malignant nodules in 2, 3 and 4 points were statistically significant (P<0.05). The manifestations of malignant nodules in UC were mostly the irregular shape, obscure boundary, no obvious enhancement, heterogeneous enhancement and visible perfusion defects, and there were statistically significant differences compared with the benign nodules (P<0.05). ROC curve showed that both sensitivity and specificity of UE and UC were superior to those of conventional US. AUC was the largest (AUC = 0.908) and the diagnostic value was the highest in the conventional US combined with UE and UC. Conventional US combined with elastography and UC can significantly improve the sensitivity, specificity and accuracy of diagnosis of benign and malignant thyroid nodules. D.A. Spandidos 2017-07 2017-05-24 /pmc/articles/PMC5494667/ /pubmed/28693244 http://dx.doi.org/10.3892/ol.2017.6245 Text en Copyright: © Liu et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Articles Liu, Mei-Juan Men, Yan-Ming Zhang, Yong-Lin Zhang, Yu-Xi Liu, Hao Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography |
title | Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography |
title_full | Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography |
title_fullStr | Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography |
title_full_unstemmed | Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography |
title_short | Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography |
title_sort | improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494667/ https://www.ncbi.nlm.nih.gov/pubmed/28693244 http://dx.doi.org/10.3892/ol.2017.6245 |
work_keys_str_mv | AT liumeijuan improvementofdiagnosticefficiencyindistinguishingthebenignandmalignantthyroidnodulesviaconventionalultrasoundcombinedwithultrasoundcontrastandelastography AT menyanming improvementofdiagnosticefficiencyindistinguishingthebenignandmalignantthyroidnodulesviaconventionalultrasoundcombinedwithultrasoundcontrastandelastography AT zhangyonglin improvementofdiagnosticefficiencyindistinguishingthebenignandmalignantthyroidnodulesviaconventionalultrasoundcombinedwithultrasoundcontrastandelastography AT zhangyuxi improvementofdiagnosticefficiencyindistinguishingthebenignandmalignantthyroidnodulesviaconventionalultrasoundcombinedwithultrasoundcontrastandelastography AT liuhao improvementofdiagnosticefficiencyindistinguishingthebenignandmalignantthyroidnodulesviaconventionalultrasoundcombinedwithultrasoundcontrastandelastography |