Cargando…

Intraoperative Transesophageal Echocardiography in the Operation of Ebstein's Anomaly: A Retrospective Study

BACKGROUND: Ebstein's anomaly (EA) has various spectrums in clinical and anatomic features. This study aimed to report the experience of two-dimensional intraoperative transesophageal echocardiography (2D-ITEE) during the EA surgery and to analyze the characteristics of the tricuspid valve (TV)...

Descripción completa

Detalles Bibliográficos
Autores principales: Tang, Xiu-Jie, Bao, Min, Zhao, He, Wang, Lian-Yi, Wu, Qing-Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494916/
https://www.ncbi.nlm.nih.gov/pubmed/28639568
http://dx.doi.org/10.4103/0366-6999.208233
_version_ 1783247741474832384
author Tang, Xiu-Jie
Bao, Min
Zhao, He
Wang, Lian-Yi
Wu, Qing-Yu
author_facet Tang, Xiu-Jie
Bao, Min
Zhao, He
Wang, Lian-Yi
Wu, Qing-Yu
author_sort Tang, Xiu-Jie
collection PubMed
description BACKGROUND: Ebstein's anomaly (EA) has various spectrums in clinical and anatomic features. This study aimed to report the experience of two-dimensional intraoperative transesophageal echocardiography (2D-ITEE) during the EA surgery and to analyze the characteristics of the tricuspid valve (TV) by comparing the data from 2D-ITEE with the results from the surgery. METHODS: 2D-ITEE data of 164 patients with EA who were operated in the First Hospital of Tsinghua University between July 2004 and April 2014 were retrospectively analyzed in this study. 2D-ITEE was applied in all patients. Downward displacement distances were measured, and the numbers of downward displacement or absent leaflets were compared with that of the surgery and with that of the two-dimensional-transthoracic echocardiogram (2D-TTE). Data comparison was performed using the Chi-square test. RESULTS: The anterior leaflet partial or total downward displacement was 37.76 ± 17.50 mm in 54 cases, absent in one patient; septal leaflet downward displacement was 29.07 ± 12.34 mm in 134 cases, absent in 17 cases; and posterior leaflet downward displacement was 43.18 ± 19.16 mm in 115 cases, absent in 34 cases. Statistically, there was no significant difference between the results from 2D-ITEE and that of 2D-TTE. The consistency rates of 2D-ITEE with operation for septal and posterior leaflets were 93.2% and 96.1%, respectively, while the rate for anterior was only 40.1%, which was significantly different. Color Doppler flow image showed severe regurgitation in 150 cases and moderate in 14 cases. After surgical correction, moderate regurgitation of TV was found in 58 cases with 2D-ITEE, repair was performed again until the effect was satisfied. No complication occurred relating to the use of 2D-ITEE. CONCLUSIONS: 2D-ITEE could help diagnose anterior leaflet, evaluate the effect of TV repair, increase operational success rate, and reduce complication.
format Online
Article
Text
id pubmed-5494916
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-54949162017-07-14 Intraoperative Transesophageal Echocardiography in the Operation of Ebstein's Anomaly: A Retrospective Study Tang, Xiu-Jie Bao, Min Zhao, He Wang, Lian-Yi Wu, Qing-Yu Chin Med J (Engl) Original Article BACKGROUND: Ebstein's anomaly (EA) has various spectrums in clinical and anatomic features. This study aimed to report the experience of two-dimensional intraoperative transesophageal echocardiography (2D-ITEE) during the EA surgery and to analyze the characteristics of the tricuspid valve (TV) by comparing the data from 2D-ITEE with the results from the surgery. METHODS: 2D-ITEE data of 164 patients with EA who were operated in the First Hospital of Tsinghua University between July 2004 and April 2014 were retrospectively analyzed in this study. 2D-ITEE was applied in all patients. Downward displacement distances were measured, and the numbers of downward displacement or absent leaflets were compared with that of the surgery and with that of the two-dimensional-transthoracic echocardiogram (2D-TTE). Data comparison was performed using the Chi-square test. RESULTS: The anterior leaflet partial or total downward displacement was 37.76 ± 17.50 mm in 54 cases, absent in one patient; septal leaflet downward displacement was 29.07 ± 12.34 mm in 134 cases, absent in 17 cases; and posterior leaflet downward displacement was 43.18 ± 19.16 mm in 115 cases, absent in 34 cases. Statistically, there was no significant difference between the results from 2D-ITEE and that of 2D-TTE. The consistency rates of 2D-ITEE with operation for septal and posterior leaflets were 93.2% and 96.1%, respectively, while the rate for anterior was only 40.1%, which was significantly different. Color Doppler flow image showed severe regurgitation in 150 cases and moderate in 14 cases. After surgical correction, moderate regurgitation of TV was found in 58 cases with 2D-ITEE, repair was performed again until the effect was satisfied. No complication occurred relating to the use of 2D-ITEE. CONCLUSIONS: 2D-ITEE could help diagnose anterior leaflet, evaluate the effect of TV repair, increase operational success rate, and reduce complication. Medknow Publications & Media Pvt Ltd 2017-07-05 /pmc/articles/PMC5494916/ /pubmed/28639568 http://dx.doi.org/10.4103/0366-6999.208233 Text en Copyright: © 2017 Chinese Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Tang, Xiu-Jie
Bao, Min
Zhao, He
Wang, Lian-Yi
Wu, Qing-Yu
Intraoperative Transesophageal Echocardiography in the Operation of Ebstein's Anomaly: A Retrospective Study
title Intraoperative Transesophageal Echocardiography in the Operation of Ebstein's Anomaly: A Retrospective Study
title_full Intraoperative Transesophageal Echocardiography in the Operation of Ebstein's Anomaly: A Retrospective Study
title_fullStr Intraoperative Transesophageal Echocardiography in the Operation of Ebstein's Anomaly: A Retrospective Study
title_full_unstemmed Intraoperative Transesophageal Echocardiography in the Operation of Ebstein's Anomaly: A Retrospective Study
title_short Intraoperative Transesophageal Echocardiography in the Operation of Ebstein's Anomaly: A Retrospective Study
title_sort intraoperative transesophageal echocardiography in the operation of ebstein's anomaly: a retrospective study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5494916/
https://www.ncbi.nlm.nih.gov/pubmed/28639568
http://dx.doi.org/10.4103/0366-6999.208233
work_keys_str_mv AT tangxiujie intraoperativetransesophagealechocardiographyintheoperationofebsteinsanomalyaretrospectivestudy
AT baomin intraoperativetransesophagealechocardiographyintheoperationofebsteinsanomalyaretrospectivestudy
AT zhaohe intraoperativetransesophagealechocardiographyintheoperationofebsteinsanomalyaretrospectivestudy
AT wanglianyi intraoperativetransesophagealechocardiographyintheoperationofebsteinsanomalyaretrospectivestudy
AT wuqingyu intraoperativetransesophagealechocardiographyintheoperationofebsteinsanomalyaretrospectivestudy