BACKGROUND: There is a need for a brain volume measure applicable to the clinical routine scans. Nearly every multiple sclerosis (MS) protocol includes low-resolution 2D T2-FLAIR imaging. OBJECTIVES: To develop and validate cross-sectional and longitudinal brain atrophy measures on clinical-quality...

Descripción completa

Detalles Bibliográficos
Autores principales: Dwyer, Michael G., Silva, Diego, Bergsland, Niels, Horakova, Dana, Ramasamy, Deepa, Durfee, Jaqueline, Vaneckova, Manuela, Havrdova, Eva, Zivadinov, Robert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5496213/
https://www.ncbi.nlm.nih.gov/pubmed/28706852
http://dx.doi.org/10.1016/j.nicl.2017.06.022
_version_ 1783247927389454336
author Dwyer, Michael G.
Silva, Diego
Bergsland, Niels
Horakova, Dana
Ramasamy, Deepa
Durfee, Jaqueline
Vaneckova, Manuela
Havrdova, Eva
Zivadinov, Robert
author_facet Dwyer, Michael G.
Silva, Diego
Bergsland, Niels
Horakova, Dana
Ramasamy, Deepa
Durfee, Jaqueline
Vaneckova, Manuela
Havrdova, Eva
Zivadinov, Robert
author_sort Dwyer, Michael G.
collection PubMed
description BACKGROUND: There is a need for a brain volume measure applicable to the clinical routine scans. Nearly every multiple sclerosis (MS) protocol includes low-resolution 2D T2-FLAIR imaging. OBJECTIVES: To develop and validate cross-sectional and longitudinal brain atrophy measures on clinical-quality T2-FLAIR images in MS patients. METHODS: A real-world dataset from 109 MS patients from 62 MRI scanners was used to develop a lateral ventricular volume (LVV) algorithm with a longitudinal Jacobian-based extension, called NeuroSTREAM. Gold-standard LVV was calculated on high-resolution T1 1 mm, while NeuroSTREAM LVV was obtained on low-resolution T2-FLAIR 3 mm thick images. Scan-rescan reliability was assessed in 5 subjects. The variability of LVV measurement at different field strengths was tested in 76 healthy controls and 125 MS patients who obtained both 1.5T and 3T scans in 72 hours. Clinical validation of algorithm was performed in 176 MS patients who obtained serial yearly MRI 1.5T scans for 10 years. RESULTS: Correlation between gold-standard high-resolution T1 LVV and low-resolution T2-FLAIR LVV was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 0.84%. Correlation between low-resolution T2-FLAIR LVV on 1.5T and 3T was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 2.69% cross-sectionally and 2.08% via Jacobian integration. NeuroSTREAM showed comparable effect size (d = 0.39–0.71) in separating MS patients with and without confirmed disability progression, compared to SIENA and VIENA. CONCLUSIONS: Brain atrophy measurement on clinical quality T2-FLAIR scans is feasible, accurate, reliable, and relates to clinical outcomes.
format Online
Article
Text
id pubmed-5496213
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-54962132017-07-13 Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis Dwyer, Michael G. Silva, Diego Bergsland, Niels Horakova, Dana Ramasamy, Deepa Durfee, Jaqueline Vaneckova, Manuela Havrdova, Eva Zivadinov, Robert Neuroimage Clin Regular Article BACKGROUND: There is a need for a brain volume measure applicable to the clinical routine scans. Nearly every multiple sclerosis (MS) protocol includes low-resolution 2D T2-FLAIR imaging. OBJECTIVES: To develop and validate cross-sectional and longitudinal brain atrophy measures on clinical-quality T2-FLAIR images in MS patients. METHODS: A real-world dataset from 109 MS patients from 62 MRI scanners was used to develop a lateral ventricular volume (LVV) algorithm with a longitudinal Jacobian-based extension, called NeuroSTREAM. Gold-standard LVV was calculated on high-resolution T1 1 mm, while NeuroSTREAM LVV was obtained on low-resolution T2-FLAIR 3 mm thick images. Scan-rescan reliability was assessed in 5 subjects. The variability of LVV measurement at different field strengths was tested in 76 healthy controls and 125 MS patients who obtained both 1.5T and 3T scans in 72 hours. Clinical validation of algorithm was performed in 176 MS patients who obtained serial yearly MRI 1.5T scans for 10 years. RESULTS: Correlation between gold-standard high-resolution T1 LVV and low-resolution T2-FLAIR LVV was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 0.84%. Correlation between low-resolution T2-FLAIR LVV on 1.5T and 3T was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 2.69% cross-sectionally and 2.08% via Jacobian integration. NeuroSTREAM showed comparable effect size (d = 0.39–0.71) in separating MS patients with and without confirmed disability progression, compared to SIENA and VIENA. CONCLUSIONS: Brain atrophy measurement on clinical quality T2-FLAIR scans is feasible, accurate, reliable, and relates to clinical outcomes. Elsevier 2017-06-19 /pmc/articles/PMC5496213/ /pubmed/28706852 http://dx.doi.org/10.1016/j.nicl.2017.06.022 Text en © 2017 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Regular Article
Dwyer, Michael G.
Silva, Diego
Bergsland, Niels
Horakova, Dana
Ramasamy, Deepa
Durfee, Jaqueline
Vaneckova, Manuela
Havrdova, Eva
Zivadinov, Robert
Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
title Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
title_full Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
title_fullStr Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
title_full_unstemmed Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
title_short Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
title_sort neurological software tool for reliable atrophy measurement (neurostream) of the lateral ventricles on clinical-quality t2-flair mri scans in multiple sclerosis
topic Regular Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5496213/
https://www.ncbi.nlm.nih.gov/pubmed/28706852
http://dx.doi.org/10.1016/j.nicl.2017.06.022
work_keys_str_mv AT dwyermichaelg neurologicalsoftwaretoolforreliableatrophymeasurementneurostreamofthelateralventriclesonclinicalqualityt2flairmriscansinmultiplesclerosis
AT silvadiego neurologicalsoftwaretoolforreliableatrophymeasurementneurostreamofthelateralventriclesonclinicalqualityt2flairmriscansinmultiplesclerosis
AT bergslandniels neurologicalsoftwaretoolforreliableatrophymeasurementneurostreamofthelateralventriclesonclinicalqualityt2flairmriscansinmultiplesclerosis
AT horakovadana neurologicalsoftwaretoolforreliableatrophymeasurementneurostreamofthelateralventriclesonclinicalqualityt2flairmriscansinmultiplesclerosis
AT ramasamydeepa neurologicalsoftwaretoolforreliableatrophymeasurementneurostreamofthelateralventriclesonclinicalqualityt2flairmriscansinmultiplesclerosis
AT durfeejaqueline neurologicalsoftwaretoolforreliableatrophymeasurementneurostreamofthelateralventriclesonclinicalqualityt2flairmriscansinmultiplesclerosis
AT vaneckovamanuela neurologicalsoftwaretoolforreliableatrophymeasurementneurostreamofthelateralventriclesonclinicalqualityt2flairmriscansinmultiplesclerosis
AT havrdovaeva neurologicalsoftwaretoolforreliableatrophymeasurementneurostreamofthelateralventriclesonclinicalqualityt2flairmriscansinmultiplesclerosis
AT zivadinovrobert neurologicalsoftwaretoolforreliableatrophymeasurementneurostreamofthelateralventriclesonclinicalqualityt2flairmriscansinmultiplesclerosis