Cargando…

Importance of preclinical evaluation of wear in hip implant designs using simulator machines()

Total hip arthroplasty (THA) is a surgical procedure that involves the replacement of the damaged joint of the hip by an artificial device. Despite the recognized clinical success of hip implants, wear of the articulating surfaces remains as one of the critical issues influencing performance. Common...

Descripción completa

Detalles Bibliográficos
Autores principales: Trommer, Rafael Mello, Maru, Márcia Marie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5496994/
https://www.ncbi.nlm.nih.gov/pubmed/28702381
http://dx.doi.org/10.1016/j.rboe.2016.07.004
_version_ 1783248078674853888
author Trommer, Rafael Mello
Maru, Márcia Marie
author_facet Trommer, Rafael Mello
Maru, Márcia Marie
author_sort Trommer, Rafael Mello
collection PubMed
description Total hip arthroplasty (THA) is a surgical procedure that involves the replacement of the damaged joint of the hip by an artificial device. Despite the recognized clinical success of hip implants, wear of the articulating surfaces remains as one of the critical issues influencing performance. Common material combinations used in hip designs comprise metal-on-polymer (MoP), ceramic-on-polymer (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). However, when the design of the hip implant is concerned besides the materials used, several parameters can influence its wear performance. In this scenario, where the safety and efficacy for the patient are the main issues, it is fundamental to evaluate and predict the wear rate of the hip implant design before its use in THA. This is one of the issues that should be taken into account in the preclinical evaluation step of the product, in which simulated laboratory tests are necessary. However, it is fundamental that the applied motions and loads can reproduce the wear mechanisms physiologically observed in the patient. To replicate the in vivo angular displacements and loadings, special machines known as joint simulators are employed. This article focuses on the main characteristics related to the wear simulation of hip implants using mechanical simulators, giving information to surgeons, researchers, regulatory bodies, etc., about the importance of preclinical wear evaluation. A critical analysis is performed on the differences in the principles of operation of simulators and their effects on the final results, and about future trends in wear simulation.
format Online
Article
Text
id pubmed-5496994
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-54969942017-07-12 Importance of preclinical evaluation of wear in hip implant designs using simulator machines() Trommer, Rafael Mello Maru, Márcia Marie Rev Bras Ortop Review Article Total hip arthroplasty (THA) is a surgical procedure that involves the replacement of the damaged joint of the hip by an artificial device. Despite the recognized clinical success of hip implants, wear of the articulating surfaces remains as one of the critical issues influencing performance. Common material combinations used in hip designs comprise metal-on-polymer (MoP), ceramic-on-polymer (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). However, when the design of the hip implant is concerned besides the materials used, several parameters can influence its wear performance. In this scenario, where the safety and efficacy for the patient are the main issues, it is fundamental to evaluate and predict the wear rate of the hip implant design before its use in THA. This is one of the issues that should be taken into account in the preclinical evaluation step of the product, in which simulated laboratory tests are necessary. However, it is fundamental that the applied motions and loads can reproduce the wear mechanisms physiologically observed in the patient. To replicate the in vivo angular displacements and loadings, special machines known as joint simulators are employed. This article focuses on the main characteristics related to the wear simulation of hip implants using mechanical simulators, giving information to surgeons, researchers, regulatory bodies, etc., about the importance of preclinical wear evaluation. A critical analysis is performed on the differences in the principles of operation of simulators and their effects on the final results, and about future trends in wear simulation. Elsevier 2016-12-30 /pmc/articles/PMC5496994/ /pubmed/28702381 http://dx.doi.org/10.1016/j.rboe.2016.07.004 Text en © 2016 Sociedade Brasileira de Ortopedia e Traumatologia. Published by Elsevier Editora Ltda. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Review Article
Trommer, Rafael Mello
Maru, Márcia Marie
Importance of preclinical evaluation of wear in hip implant designs using simulator machines()
title Importance of preclinical evaluation of wear in hip implant designs using simulator machines()
title_full Importance of preclinical evaluation of wear in hip implant designs using simulator machines()
title_fullStr Importance of preclinical evaluation of wear in hip implant designs using simulator machines()
title_full_unstemmed Importance of preclinical evaluation of wear in hip implant designs using simulator machines()
title_short Importance of preclinical evaluation of wear in hip implant designs using simulator machines()
title_sort importance of preclinical evaluation of wear in hip implant designs using simulator machines()
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5496994/
https://www.ncbi.nlm.nih.gov/pubmed/28702381
http://dx.doi.org/10.1016/j.rboe.2016.07.004
work_keys_str_mv AT trommerrafaelmello importanceofpreclinicalevaluationofwearinhipimplantdesignsusingsimulatormachines
AT marumarciamarie importanceofpreclinicalevaluationofwearinhipimplantdesignsusingsimulatormachines