Cargando…
Changes in the reference lumen size of target lesions before and after coronary stent implantation: Evaluation with frequency domain optical coherence tomography()()
OBJECTIVE: In optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI), stent size is usually determined according to the pre-PCI lumen size of either the distal or proximal reference site. However, the effect of the OCT imaging catheter crossing the target lesion on the re...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5497265/ https://www.ncbi.nlm.nih.gov/pubmed/28785691 http://dx.doi.org/10.1016/j.ijcha.2015.06.003 |
_version_ | 1783248128575537152 |
---|---|
author | Kurokawa, Muneo Uemura, Shiro Watanabe, Makoto Dote, Yoko Sugawara, Yu Goryo, Yutaka Ueda, Tomoya Okayama, Satoshi Kayashima, Michinori Saito, Yoshihiko |
author_facet | Kurokawa, Muneo Uemura, Shiro Watanabe, Makoto Dote, Yoko Sugawara, Yu Goryo, Yutaka Ueda, Tomoya Okayama, Satoshi Kayashima, Michinori Saito, Yoshihiko |
author_sort | Kurokawa, Muneo |
collection | PubMed |
description | OBJECTIVE: In optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI), stent size is usually determined according to the pre-PCI lumen size of either the distal or proximal reference site. However, the effect of the OCT imaging catheter crossing the target lesion on the reference lumen measurements has not been studied. We evaluated changes in the reference lumen size before and after PCI using frequency domain OCT. METHODS: For 100 consecutive patients with PCI, mean lumen diameter (LD) and lumen area (LA) were measured at the proximal and distal reference sites before and after coronary stent implantation with OCT. RESULTS: Mean LD and LA of the distal reference site were significantly increased after PCI with stent implantation (2.57 ± 0.6 to 2.62 ± 0.64 mm, p < 0.01 and 5.20 ± 2.66 to 5.41 ± 2.54 mm(2), p < 0.01, respectively). By contrast, these indices at the proximal reference site were significantly decreased. ROC curve analysis selected MLA of 1.50 mm(2) as the best cutoff value for changes in mean LD. Distal mean LD was markedly increased after PCI in lesions with MLA < 1.50 mm (2.28 ± 0.48 to 2.40 ± 0.17 mm, P < 0.001), but did not change in lesions with MLA > 1.50 mm(2). Tissue characteristics were not correlated with changes in reference lumen size. CONCLUSIONS: When we select the stent size during OCT-guided PCI, we need to pay attention to the decrease in the luminal measurement of the reference sites, especially in lesions with tight stenosis. |
format | Online Article Text |
id | pubmed-5497265 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-54972652017-08-07 Changes in the reference lumen size of target lesions before and after coronary stent implantation: Evaluation with frequency domain optical coherence tomography()() Kurokawa, Muneo Uemura, Shiro Watanabe, Makoto Dote, Yoko Sugawara, Yu Goryo, Yutaka Ueda, Tomoya Okayama, Satoshi Kayashima, Michinori Saito, Yoshihiko Int J Cardiol Heart Vasc Article OBJECTIVE: In optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI), stent size is usually determined according to the pre-PCI lumen size of either the distal or proximal reference site. However, the effect of the OCT imaging catheter crossing the target lesion on the reference lumen measurements has not been studied. We evaluated changes in the reference lumen size before and after PCI using frequency domain OCT. METHODS: For 100 consecutive patients with PCI, mean lumen diameter (LD) and lumen area (LA) were measured at the proximal and distal reference sites before and after coronary stent implantation with OCT. RESULTS: Mean LD and LA of the distal reference site were significantly increased after PCI with stent implantation (2.57 ± 0.6 to 2.62 ± 0.64 mm, p < 0.01 and 5.20 ± 2.66 to 5.41 ± 2.54 mm(2), p < 0.01, respectively). By contrast, these indices at the proximal reference site were significantly decreased. ROC curve analysis selected MLA of 1.50 mm(2) as the best cutoff value for changes in mean LD. Distal mean LD was markedly increased after PCI in lesions with MLA < 1.50 mm (2.28 ± 0.48 to 2.40 ± 0.17 mm, P < 0.001), but did not change in lesions with MLA > 1.50 mm(2). Tissue characteristics were not correlated with changes in reference lumen size. CONCLUSIONS: When we select the stent size during OCT-guided PCI, we need to pay attention to the decrease in the luminal measurement of the reference sites, especially in lesions with tight stenosis. Elsevier 2015-06-17 /pmc/articles/PMC5497265/ /pubmed/28785691 http://dx.doi.org/10.1016/j.ijcha.2015.06.003 Text en © 2015 Published by Elsevier Ireland Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Kurokawa, Muneo Uemura, Shiro Watanabe, Makoto Dote, Yoko Sugawara, Yu Goryo, Yutaka Ueda, Tomoya Okayama, Satoshi Kayashima, Michinori Saito, Yoshihiko Changes in the reference lumen size of target lesions before and after coronary stent implantation: Evaluation with frequency domain optical coherence tomography()() |
title | Changes in the reference lumen size of target lesions before and after coronary stent implantation: Evaluation with frequency domain optical coherence tomography()() |
title_full | Changes in the reference lumen size of target lesions before and after coronary stent implantation: Evaluation with frequency domain optical coherence tomography()() |
title_fullStr | Changes in the reference lumen size of target lesions before and after coronary stent implantation: Evaluation with frequency domain optical coherence tomography()() |
title_full_unstemmed | Changes in the reference lumen size of target lesions before and after coronary stent implantation: Evaluation with frequency domain optical coherence tomography()() |
title_short | Changes in the reference lumen size of target lesions before and after coronary stent implantation: Evaluation with frequency domain optical coherence tomography()() |
title_sort | changes in the reference lumen size of target lesions before and after coronary stent implantation: evaluation with frequency domain optical coherence tomography()() |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5497265/ https://www.ncbi.nlm.nih.gov/pubmed/28785691 http://dx.doi.org/10.1016/j.ijcha.2015.06.003 |
work_keys_str_mv | AT kurokawamuneo changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography AT uemurashiro changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography AT watanabemakoto changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography AT doteyoko changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography AT sugawarayu changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography AT goryoyutaka changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography AT uedatomoya changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography AT okayamasatoshi changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography AT kayashimamichinori changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography AT saitoyoshihiko changesinthereferencelumensizeoftargetlesionsbeforeandaftercoronarystentimplantationevaluationwithfrequencydomainopticalcoherencetomography |