Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study
OBJECTIVE: To step-wise evaluate image quality of sinogram-affirmed iterative reconstruction (SAFIRE) in reduced-dose (RD) thoracoabdominal computed tomography (CT) compared to full-dose (FD) and RD filtered back projection (FBP) in a longitudinal study. MATERIALS AND METHODS: 122 patients were incl...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5498038/ https://www.ncbi.nlm.nih.gov/pubmed/28678818 http://dx.doi.org/10.1371/journal.pone.0180302 |
_version_ | 1783248241581621248 |
---|---|
author | Scharf, Michael Brendel, Stephanie Melzer, Katja Hentschke, Christian May, Matthias Uder, Michael Lell, Michael M. |
author_facet | Scharf, Michael Brendel, Stephanie Melzer, Katja Hentschke, Christian May, Matthias Uder, Michael Lell, Michael M. |
author_sort | Scharf, Michael |
collection | PubMed |
description | OBJECTIVE: To step-wise evaluate image quality of sinogram-affirmed iterative reconstruction (SAFIRE) in reduced-dose (RD) thoracoabdominal computed tomography (CT) compared to full-dose (FD) and RD filtered back projection (FBP) in a longitudinal study. MATERIALS AND METHODS: 122 patients were included in this prospective study. 49 patients (14 men: mean age ± SD, 56±0.4 years; 35 women: 58±1.3 years) completed FD, RD1 (80%-dose) and RD2 (60%-dose) thoracoabdominal CT. Each CT dataset was reconstructed with FBP and SAFIRE. For quantitative image analysis image noise was measured in defined tissue regions. Qualitative image evaluation was performed according to the European Guidelines on Quality criteria for CT. Additionally artifacts, lesion conspicuity, and edge sharpness were assessed. RESULTS: Compared to FD-FBP noise in soft tissue increased by 12% in RD1-FBP and 27% in RD2-FBP reconstructions, whereas SAFIRE lead to a decrease of 28% (RD1) and 17% (RD2), respectively (all p <0.001). Visually sharp reproduction, lesion conspicuity, edge sharpness of pathologic findings, and overall image quality did not differ statistically significant between FD-FBP and RD-SAFIRE datasets. Image quality decreased in RD1- and RD2-FBP compared to FD-FBP, reaching statistically significance in RD2 datasets (p <0.001). In RD1- and RD2-FBP (p <0.001) streak artifacts were noted. CONCLUSION: Using SAFIRE the reference mAs in thoracoabdominal CT can be reduced by at least 30% in clinical routine without loss of image quality or diagnostic information. |
format | Online Article Text |
id | pubmed-5498038 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-54980382017-07-25 Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study Scharf, Michael Brendel, Stephanie Melzer, Katja Hentschke, Christian May, Matthias Uder, Michael Lell, Michael M. PLoS One Research Article OBJECTIVE: To step-wise evaluate image quality of sinogram-affirmed iterative reconstruction (SAFIRE) in reduced-dose (RD) thoracoabdominal computed tomography (CT) compared to full-dose (FD) and RD filtered back projection (FBP) in a longitudinal study. MATERIALS AND METHODS: 122 patients were included in this prospective study. 49 patients (14 men: mean age ± SD, 56±0.4 years; 35 women: 58±1.3 years) completed FD, RD1 (80%-dose) and RD2 (60%-dose) thoracoabdominal CT. Each CT dataset was reconstructed with FBP and SAFIRE. For quantitative image analysis image noise was measured in defined tissue regions. Qualitative image evaluation was performed according to the European Guidelines on Quality criteria for CT. Additionally artifacts, lesion conspicuity, and edge sharpness were assessed. RESULTS: Compared to FD-FBP noise in soft tissue increased by 12% in RD1-FBP and 27% in RD2-FBP reconstructions, whereas SAFIRE lead to a decrease of 28% (RD1) and 17% (RD2), respectively (all p <0.001). Visually sharp reproduction, lesion conspicuity, edge sharpness of pathologic findings, and overall image quality did not differ statistically significant between FD-FBP and RD-SAFIRE datasets. Image quality decreased in RD1- and RD2-FBP compared to FD-FBP, reaching statistically significance in RD2 datasets (p <0.001). In RD1- and RD2-FBP (p <0.001) streak artifacts were noted. CONCLUSION: Using SAFIRE the reference mAs in thoracoabdominal CT can be reduced by at least 30% in clinical routine without loss of image quality or diagnostic information. Public Library of Science 2017-07-05 /pmc/articles/PMC5498038/ /pubmed/28678818 http://dx.doi.org/10.1371/journal.pone.0180302 Text en © 2017 Scharf et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Scharf, Michael Brendel, Stephanie Melzer, Katja Hentschke, Christian May, Matthias Uder, Michael Lell, Michael M. Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study |
title | Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study |
title_full | Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study |
title_fullStr | Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study |
title_full_unstemmed | Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study |
title_short | Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study |
title_sort | image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal ct, using sinogram affirmed iterative reconstruction (safire) technique in a longitudinal study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5498038/ https://www.ncbi.nlm.nih.gov/pubmed/28678818 http://dx.doi.org/10.1371/journal.pone.0180302 |
work_keys_str_mv | AT scharfmichael imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy AT brendelstephanie imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy AT melzerkatja imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy AT hentschkechristian imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy AT maymatthias imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy AT udermichael imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy AT lellmichaelm imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy |