Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study

OBJECTIVE: To step-wise evaluate image quality of sinogram-affirmed iterative reconstruction (SAFIRE) in reduced-dose (RD) thoracoabdominal computed tomography (CT) compared to full-dose (FD) and RD filtered back projection (FBP) in a longitudinal study. MATERIALS AND METHODS: 122 patients were incl...

Descripción completa

Detalles Bibliográficos
Autores principales: Scharf, Michael, Brendel, Stephanie, Melzer, Katja, Hentschke, Christian, May, Matthias, Uder, Michael, Lell, Michael M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5498038/
https://www.ncbi.nlm.nih.gov/pubmed/28678818
http://dx.doi.org/10.1371/journal.pone.0180302
_version_ 1783248241581621248
author Scharf, Michael
Brendel, Stephanie
Melzer, Katja
Hentschke, Christian
May, Matthias
Uder, Michael
Lell, Michael M.
author_facet Scharf, Michael
Brendel, Stephanie
Melzer, Katja
Hentschke, Christian
May, Matthias
Uder, Michael
Lell, Michael M.
author_sort Scharf, Michael
collection PubMed
description OBJECTIVE: To step-wise evaluate image quality of sinogram-affirmed iterative reconstruction (SAFIRE) in reduced-dose (RD) thoracoabdominal computed tomography (CT) compared to full-dose (FD) and RD filtered back projection (FBP) in a longitudinal study. MATERIALS AND METHODS: 122 patients were included in this prospective study. 49 patients (14 men: mean age ± SD, 56±0.4 years; 35 women: 58±1.3 years) completed FD, RD1 (80%-dose) and RD2 (60%-dose) thoracoabdominal CT. Each CT dataset was reconstructed with FBP and SAFIRE. For quantitative image analysis image noise was measured in defined tissue regions. Qualitative image evaluation was performed according to the European Guidelines on Quality criteria for CT. Additionally artifacts, lesion conspicuity, and edge sharpness were assessed. RESULTS: Compared to FD-FBP noise in soft tissue increased by 12% in RD1-FBP and 27% in RD2-FBP reconstructions, whereas SAFIRE lead to a decrease of 28% (RD1) and 17% (RD2), respectively (all p <0.001). Visually sharp reproduction, lesion conspicuity, edge sharpness of pathologic findings, and overall image quality did not differ statistically significant between FD-FBP and RD-SAFIRE datasets. Image quality decreased in RD1- and RD2-FBP compared to FD-FBP, reaching statistically significance in RD2 datasets (p <0.001). In RD1- and RD2-FBP (p <0.001) streak artifacts were noted. CONCLUSION: Using SAFIRE the reference mAs in thoracoabdominal CT can be reduced by at least 30% in clinical routine without loss of image quality or diagnostic information.
format Online
Article
Text
id pubmed-5498038
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-54980382017-07-25 Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study Scharf, Michael Brendel, Stephanie Melzer, Katja Hentschke, Christian May, Matthias Uder, Michael Lell, Michael M. PLoS One Research Article OBJECTIVE: To step-wise evaluate image quality of sinogram-affirmed iterative reconstruction (SAFIRE) in reduced-dose (RD) thoracoabdominal computed tomography (CT) compared to full-dose (FD) and RD filtered back projection (FBP) in a longitudinal study. MATERIALS AND METHODS: 122 patients were included in this prospective study. 49 patients (14 men: mean age ± SD, 56±0.4 years; 35 women: 58±1.3 years) completed FD, RD1 (80%-dose) and RD2 (60%-dose) thoracoabdominal CT. Each CT dataset was reconstructed with FBP and SAFIRE. For quantitative image analysis image noise was measured in defined tissue regions. Qualitative image evaluation was performed according to the European Guidelines on Quality criteria for CT. Additionally artifacts, lesion conspicuity, and edge sharpness were assessed. RESULTS: Compared to FD-FBP noise in soft tissue increased by 12% in RD1-FBP and 27% in RD2-FBP reconstructions, whereas SAFIRE lead to a decrease of 28% (RD1) and 17% (RD2), respectively (all p <0.001). Visually sharp reproduction, lesion conspicuity, edge sharpness of pathologic findings, and overall image quality did not differ statistically significant between FD-FBP and RD-SAFIRE datasets. Image quality decreased in RD1- and RD2-FBP compared to FD-FBP, reaching statistically significance in RD2 datasets (p <0.001). In RD1- and RD2-FBP (p <0.001) streak artifacts were noted. CONCLUSION: Using SAFIRE the reference mAs in thoracoabdominal CT can be reduced by at least 30% in clinical routine without loss of image quality or diagnostic information. Public Library of Science 2017-07-05 /pmc/articles/PMC5498038/ /pubmed/28678818 http://dx.doi.org/10.1371/journal.pone.0180302 Text en © 2017 Scharf et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Scharf, Michael
Brendel, Stephanie
Melzer, Katja
Hentschke, Christian
May, Matthias
Uder, Michael
Lell, Michael M.
Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study
title Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study
title_full Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study
title_fullStr Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study
title_full_unstemmed Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study
title_short Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study
title_sort image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal ct, using sinogram affirmed iterative reconstruction (safire) technique in a longitudinal study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5498038/
https://www.ncbi.nlm.nih.gov/pubmed/28678818
http://dx.doi.org/10.1371/journal.pone.0180302
work_keys_str_mv AT scharfmichael imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy
AT brendelstephanie imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy
AT melzerkatja imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy
AT hentschkechristian imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy
AT maymatthias imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy
AT udermichael imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy
AT lellmichaelm imagequalitydiagnosticaccuracyandpotentialforradiationdosereductioninthoracoabdominalctusingsinogramaffirmediterativereconstructionsafiretechniqueinalongitudinalstudy