Cargando…

Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience

In (helicopter) emergency medical services, (H)EMS, the prehospital detection of intracranial hematomas should improve patient care and the triage to specialized neurosurgical hospitals. Recently, noninvasive detection of intracranial hematomas became possible by applying transcranial near infrared...

Descripción completa

Detalles Bibliográficos
Autores principales: Schober, Patrick, Bossers, Sebastiaan M., Schwarte, Lothar A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5498904/
https://www.ncbi.nlm.nih.gov/pubmed/28717647
http://dx.doi.org/10.1155/2017/1846830
_version_ 1783248373767208960
author Schober, Patrick
Bossers, Sebastiaan M.
Schwarte, Lothar A.
author_facet Schober, Patrick
Bossers, Sebastiaan M.
Schwarte, Lothar A.
author_sort Schober, Patrick
collection PubMed
description In (helicopter) emergency medical services, (H)EMS, the prehospital detection of intracranial hematomas should improve patient care and the triage to specialized neurosurgical hospitals. Recently, noninvasive detection of intracranial hematomas became possible by applying transcranial near infrared spectroscopy (NIRS). Herein, second-generation devices are currently available, for example, the Infrascanner 2000 (Infrascan), that appear suited also for prehospital (H)EMS applications. Since (H)EMS operations are time-critical, we studied the Infrascanner 2000 as a “first-time-right” monitor in healthy volunteers (n = 17, hospital employees, no neurologic history). Further, we studied the implementation of the Infrascanner 2000 in a European HEMS organization (Lifeliner 1, Amsterdam, The Netherlands). The principal results of our study were as follows: The screening for intracranial hematomas in healthy volunteers with first-time-right intention resulted in a marked rate of virtual hematomas (false positive results, i.e., 12/17), rendering more time consuming repeat measurements advisable. The results of the implementation of the Infrascanner in HEMS suggest that NIRS-based intracranial hematoma detection is feasible in the HEMS setting. However, some drawbacks exist and their possible solutions are discussed. Future studies will have to demonstrate how NIRS-based intracranial hematoma detection will improve prehospital decision making in (H)EMS and ultimately patient outcome.
format Online
Article
Text
id pubmed-5498904
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-54989042017-07-17 Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience Schober, Patrick Bossers, Sebastiaan M. Schwarte, Lothar A. Biomed Res Int Clinical Study In (helicopter) emergency medical services, (H)EMS, the prehospital detection of intracranial hematomas should improve patient care and the triage to specialized neurosurgical hospitals. Recently, noninvasive detection of intracranial hematomas became possible by applying transcranial near infrared spectroscopy (NIRS). Herein, second-generation devices are currently available, for example, the Infrascanner 2000 (Infrascan), that appear suited also for prehospital (H)EMS applications. Since (H)EMS operations are time-critical, we studied the Infrascanner 2000 as a “first-time-right” monitor in healthy volunteers (n = 17, hospital employees, no neurologic history). Further, we studied the implementation of the Infrascanner 2000 in a European HEMS organization (Lifeliner 1, Amsterdam, The Netherlands). The principal results of our study were as follows: The screening for intracranial hematomas in healthy volunteers with first-time-right intention resulted in a marked rate of virtual hematomas (false positive results, i.e., 12/17), rendering more time consuming repeat measurements advisable. The results of the implementation of the Infrascanner in HEMS suggest that NIRS-based intracranial hematoma detection is feasible in the HEMS setting. However, some drawbacks exist and their possible solutions are discussed. Future studies will have to demonstrate how NIRS-based intracranial hematoma detection will improve prehospital decision making in (H)EMS and ultimately patient outcome. Hindawi 2017 2017-06-22 /pmc/articles/PMC5498904/ /pubmed/28717647 http://dx.doi.org/10.1155/2017/1846830 Text en Copyright © 2017 Patrick Schober et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Schober, Patrick
Bossers, Sebastiaan M.
Schwarte, Lothar A.
Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience
title Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience
title_full Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience
title_fullStr Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience
title_full_unstemmed Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience
title_short Intracranial Hematoma Detection by Near Infrared Spectroscopy in a Helicopter Emergency Medical Service: Practical Experience
title_sort intracranial hematoma detection by near infrared spectroscopy in a helicopter emergency medical service: practical experience
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5498904/
https://www.ncbi.nlm.nih.gov/pubmed/28717647
http://dx.doi.org/10.1155/2017/1846830
work_keys_str_mv AT schoberpatrick intracranialhematomadetectionbynearinfraredspectroscopyinahelicopteremergencymedicalservicepracticalexperience
AT bosserssebastiaanm intracranialhematomadetectionbynearinfraredspectroscopyinahelicopteremergencymedicalservicepracticalexperience
AT schwartelothara intracranialhematomadetectionbynearinfraredspectroscopyinahelicopteremergencymedicalservicepracticalexperience