Cargando…
Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM
The longevity of hip prostheses is contingent on the stability of the implant within the cavity of the femur bone. The cemented fixation was mostly adopted owing to offering the immediate stability from cement-stem and cement-bone bonding interfaces after implant surgery. Yet cement damage and stres...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5499240/ https://www.ncbi.nlm.nih.gov/pubmed/28717644 http://dx.doi.org/10.1155/2017/3069351 |
_version_ | 1783248434531139584 |
---|---|
author | Ait Moussa, Abdellah Yadav, Rohan |
author_facet | Ait Moussa, Abdellah Yadav, Rohan |
author_sort | Ait Moussa, Abdellah |
collection | PubMed |
description | The longevity of hip prostheses is contingent on the stability of the implant within the cavity of the femur bone. The cemented fixation was mostly adopted owing to offering the immediate stability from cement-stem and cement-bone bonding interfaces after implant surgery. Yet cement damage and stress shielding of the bone were proven to adversely affect the lifelong stability of the implant, especially among younger subjects who tend to have an active lifestyle. The geometry and material distribution of the implant can be optimized more efficiently with a three-dimensional realistic design of a functionally graded material (FGM). We report an efficient numerical technique for achieving this objective, for maximum performance stress shielding and the rate of early accumulation of cement damage were concurrently minimized. Results indicated less stress shielding and similar cement damage rates with a 2D-FGM implant compared to 1D-FGM and Titanium alloy implants. |
format | Online Article Text |
id | pubmed-5499240 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-54992402017-07-17 Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM Ait Moussa, Abdellah Yadav, Rohan J Med Eng Research Article The longevity of hip prostheses is contingent on the stability of the implant within the cavity of the femur bone. The cemented fixation was mostly adopted owing to offering the immediate stability from cement-stem and cement-bone bonding interfaces after implant surgery. Yet cement damage and stress shielding of the bone were proven to adversely affect the lifelong stability of the implant, especially among younger subjects who tend to have an active lifestyle. The geometry and material distribution of the implant can be optimized more efficiently with a three-dimensional realistic design of a functionally graded material (FGM). We report an efficient numerical technique for achieving this objective, for maximum performance stress shielding and the rate of early accumulation of cement damage were concurrently minimized. Results indicated less stress shielding and similar cement damage rates with a 2D-FGM implant compared to 1D-FGM and Titanium alloy implants. Hindawi 2017 2017-06-21 /pmc/articles/PMC5499240/ /pubmed/28717644 http://dx.doi.org/10.1155/2017/3069351 Text en Copyright © 2017 Abdellah Ait Moussa and Rohan Yadav. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ait Moussa, Abdellah Yadav, Rohan Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM |
title | Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM |
title_full | Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM |
title_fullStr | Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM |
title_full_unstemmed | Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM |
title_short | Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM |
title_sort | optimization of a functionally graded material stem in the femoral component of a cemented hip arthroplasty: influence of dimensionality of fgm |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5499240/ https://www.ncbi.nlm.nih.gov/pubmed/28717644 http://dx.doi.org/10.1155/2017/3069351 |
work_keys_str_mv | AT aitmoussaabdellah optimizationofafunctionallygradedmaterialsteminthefemoralcomponentofacementedhiparthroplastyinfluenceofdimensionalityoffgm AT yadavrohan optimizationofafunctionallygradedmaterialsteminthefemoralcomponentofacementedhiparthroplastyinfluenceofdimensionalityoffgm |