Cargando…

Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM

The longevity of hip prostheses is contingent on the stability of the implant within the cavity of the femur bone. The cemented fixation was mostly adopted owing to offering the immediate stability from cement-stem and cement-bone bonding interfaces after implant surgery. Yet cement damage and stres...

Descripción completa

Detalles Bibliográficos
Autores principales: Ait Moussa, Abdellah, Yadav, Rohan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5499240/
https://www.ncbi.nlm.nih.gov/pubmed/28717644
http://dx.doi.org/10.1155/2017/3069351
_version_ 1783248434531139584
author Ait Moussa, Abdellah
Yadav, Rohan
author_facet Ait Moussa, Abdellah
Yadav, Rohan
author_sort Ait Moussa, Abdellah
collection PubMed
description The longevity of hip prostheses is contingent on the stability of the implant within the cavity of the femur bone. The cemented fixation was mostly adopted owing to offering the immediate stability from cement-stem and cement-bone bonding interfaces after implant surgery. Yet cement damage and stress shielding of the bone were proven to adversely affect the lifelong stability of the implant, especially among younger subjects who tend to have an active lifestyle. The geometry and material distribution of the implant can be optimized more efficiently with a three-dimensional realistic design of a functionally graded material (FGM). We report an efficient numerical technique for achieving this objective, for maximum performance stress shielding and the rate of early accumulation of cement damage were concurrently minimized. Results indicated less stress shielding and similar cement damage rates with a 2D-FGM implant compared to 1D-FGM and Titanium alloy implants.
format Online
Article
Text
id pubmed-5499240
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-54992402017-07-17 Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM Ait Moussa, Abdellah Yadav, Rohan J Med Eng Research Article The longevity of hip prostheses is contingent on the stability of the implant within the cavity of the femur bone. The cemented fixation was mostly adopted owing to offering the immediate stability from cement-stem and cement-bone bonding interfaces after implant surgery. Yet cement damage and stress shielding of the bone were proven to adversely affect the lifelong stability of the implant, especially among younger subjects who tend to have an active lifestyle. The geometry and material distribution of the implant can be optimized more efficiently with a three-dimensional realistic design of a functionally graded material (FGM). We report an efficient numerical technique for achieving this objective, for maximum performance stress shielding and the rate of early accumulation of cement damage were concurrently minimized. Results indicated less stress shielding and similar cement damage rates with a 2D-FGM implant compared to 1D-FGM and Titanium alloy implants. Hindawi 2017 2017-06-21 /pmc/articles/PMC5499240/ /pubmed/28717644 http://dx.doi.org/10.1155/2017/3069351 Text en Copyright © 2017 Abdellah Ait Moussa and Rohan Yadav. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ait Moussa, Abdellah
Yadav, Rohan
Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM
title Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM
title_full Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM
title_fullStr Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM
title_full_unstemmed Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM
title_short Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM
title_sort optimization of a functionally graded material stem in the femoral component of a cemented hip arthroplasty: influence of dimensionality of fgm
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5499240/
https://www.ncbi.nlm.nih.gov/pubmed/28717644
http://dx.doi.org/10.1155/2017/3069351
work_keys_str_mv AT aitmoussaabdellah optimizationofafunctionallygradedmaterialsteminthefemoralcomponentofacementedhiparthroplastyinfluenceofdimensionalityoffgm
AT yadavrohan optimizationofafunctionallygradedmaterialsteminthefemoralcomponentofacementedhiparthroplastyinfluenceofdimensionalityoffgm