Cargando…
Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method
The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgica...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5500061/ https://www.ncbi.nlm.nih.gov/pubmed/28658139 http://dx.doi.org/10.1097/MD.0000000000007310 |
_version_ | 1783248580952195072 |
---|---|
author | Hu, Ying Kai Xie, Qian Yang Yang, Chi Xu, Guang Zhou |
author_facet | Hu, Ying Kai Xie, Qian Yang Yang, Chi Xu, Guang Zhou |
author_sort | Hu, Ying Kai |
collection | PubMed |
description | The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgical guide (group I), and 4 without it (group II) were included in the study. The surgical design was to construct a trapdoor pedicle on the superior mucoperiosteal attachment with application of piezosurgery. The bone lid was repositioned after mesiodens extraction. Group I patients underwent surgeries based on the preoperative planning with surgical guide templates, while group II patients underwent free-hand operation. The outcome variables were success rate, intraoperative time, anterior nasal spine (ANS) position, changes of nasolabial angle (NLA), and major complications. Data from the 2 groups were compared by SPSS 17.0, using Wilcoxon test. The operative time was significantly shorter in group I patients. All the mesiodentes were extracted successfully and no obvious differences of preoperative and postoperative ANS position and NLA value were found in both groups. The patients were all recovered uneventfully. Surgical guide templates can enhance clinical accuracy and reduce operative time by facilitating accurate osteotomies. |
format | Online Article Text |
id | pubmed-5500061 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-55000612017-07-17 Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method Hu, Ying Kai Xie, Qian Yang Yang, Chi Xu, Guang Zhou Medicine (Baltimore) 5900 The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgical guide (group I), and 4 without it (group II) were included in the study. The surgical design was to construct a trapdoor pedicle on the superior mucoperiosteal attachment with application of piezosurgery. The bone lid was repositioned after mesiodens extraction. Group I patients underwent surgeries based on the preoperative planning with surgical guide templates, while group II patients underwent free-hand operation. The outcome variables were success rate, intraoperative time, anterior nasal spine (ANS) position, changes of nasolabial angle (NLA), and major complications. Data from the 2 groups were compared by SPSS 17.0, using Wilcoxon test. The operative time was significantly shorter in group I patients. All the mesiodentes were extracted successfully and no obvious differences of preoperative and postoperative ANS position and NLA value were found in both groups. The patients were all recovered uneventfully. Surgical guide templates can enhance clinical accuracy and reduce operative time by facilitating accurate osteotomies. Wolters Kluwer Health 2017-06-30 /pmc/articles/PMC5500061/ /pubmed/28658139 http://dx.doi.org/10.1097/MD.0000000000007310 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0 |
spellingShingle | 5900 Hu, Ying Kai Xie, Qian Yang Yang, Chi Xu, Guang Zhou Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method |
title | Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method |
title_full | Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method |
title_fullStr | Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method |
title_full_unstemmed | Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method |
title_short | Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method |
title_sort | computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method |
topic | 5900 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5500061/ https://www.ncbi.nlm.nih.gov/pubmed/28658139 http://dx.doi.org/10.1097/MD.0000000000007310 |
work_keys_str_mv | AT huyingkai computerdesignedsurgicalguidetemplatecomparedwithfreehandoperationformesiodensextractioninpremaxillausingtrapdoormethod AT xieqianyang computerdesignedsurgicalguidetemplatecomparedwithfreehandoperationformesiodensextractioninpremaxillausingtrapdoormethod AT yangchi computerdesignedsurgicalguidetemplatecomparedwithfreehandoperationformesiodensextractioninpremaxillausingtrapdoormethod AT xuguangzhou computerdesignedsurgicalguidetemplatecomparedwithfreehandoperationformesiodensextractioninpremaxillausingtrapdoormethod |