Cargando…

Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method

The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgica...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Ying Kai, Xie, Qian Yang, Yang, Chi, Xu, Guang Zhou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5500061/
https://www.ncbi.nlm.nih.gov/pubmed/28658139
http://dx.doi.org/10.1097/MD.0000000000007310
_version_ 1783248580952195072
author Hu, Ying Kai
Xie, Qian Yang
Yang, Chi
Xu, Guang Zhou
author_facet Hu, Ying Kai
Xie, Qian Yang
Yang, Chi
Xu, Guang Zhou
author_sort Hu, Ying Kai
collection PubMed
description The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgical guide (group I), and 4 without it (group II) were included in the study. The surgical design was to construct a trapdoor pedicle on the superior mucoperiosteal attachment with application of piezosurgery. The bone lid was repositioned after mesiodens extraction. Group I patients underwent surgeries based on the preoperative planning with surgical guide templates, while group II patients underwent free-hand operation. The outcome variables were success rate, intraoperative time, anterior nasal spine (ANS) position, changes of nasolabial angle (NLA), and major complications. Data from the 2 groups were compared by SPSS 17.0, using Wilcoxon test. The operative time was significantly shorter in group I patients. All the mesiodentes were extracted successfully and no obvious differences of preoperative and postoperative ANS position and NLA value were found in both groups. The patients were all recovered uneventfully. Surgical guide templates can enhance clinical accuracy and reduce operative time by facilitating accurate osteotomies.
format Online
Article
Text
id pubmed-5500061
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-55000612017-07-17 Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method Hu, Ying Kai Xie, Qian Yang Yang, Chi Xu, Guang Zhou Medicine (Baltimore) 5900 The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgical guide (group I), and 4 without it (group II) were included in the study. The surgical design was to construct a trapdoor pedicle on the superior mucoperiosteal attachment with application of piezosurgery. The bone lid was repositioned after mesiodens extraction. Group I patients underwent surgeries based on the preoperative planning with surgical guide templates, while group II patients underwent free-hand operation. The outcome variables were success rate, intraoperative time, anterior nasal spine (ANS) position, changes of nasolabial angle (NLA), and major complications. Data from the 2 groups were compared by SPSS 17.0, using Wilcoxon test. The operative time was significantly shorter in group I patients. All the mesiodentes were extracted successfully and no obvious differences of preoperative and postoperative ANS position and NLA value were found in both groups. The patients were all recovered uneventfully. Surgical guide templates can enhance clinical accuracy and reduce operative time by facilitating accurate osteotomies. Wolters Kluwer Health 2017-06-30 /pmc/articles/PMC5500061/ /pubmed/28658139 http://dx.doi.org/10.1097/MD.0000000000007310 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle 5900
Hu, Ying Kai
Xie, Qian Yang
Yang, Chi
Xu, Guang Zhou
Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method
title Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method
title_full Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method
title_fullStr Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method
title_full_unstemmed Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method
title_short Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method
title_sort computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method
topic 5900
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5500061/
https://www.ncbi.nlm.nih.gov/pubmed/28658139
http://dx.doi.org/10.1097/MD.0000000000007310
work_keys_str_mv AT huyingkai computerdesignedsurgicalguidetemplatecomparedwithfreehandoperationformesiodensextractioninpremaxillausingtrapdoormethod
AT xieqianyang computerdesignedsurgicalguidetemplatecomparedwithfreehandoperationformesiodensextractioninpremaxillausingtrapdoormethod
AT yangchi computerdesignedsurgicalguidetemplatecomparedwithfreehandoperationformesiodensextractioninpremaxillausingtrapdoormethod
AT xuguangzhou computerdesignedsurgicalguidetemplatecomparedwithfreehandoperationformesiodensextractioninpremaxillausingtrapdoormethod