Cargando…

Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy

The value of capnography during procedural sedation and analgesia (PSA) for the detection of hypoxaemia during upper gastrointestinal (UGI) endoscopic procedures is limited. Photoplethysmography respiratory rate (RRp) monitoring may provide a useful alternative, but the level of agreement with capno...

Descripción completa

Detalles Bibliográficos
Autores principales: Touw, Hugo R. W., Verheul, Milou H., Tuinman, Pieter R., Smit, Jeroen, Thöne, Deirdre, Schober, Patrick, Boer, Christa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5500676/
https://www.ncbi.nlm.nih.gov/pubmed/27236561
http://dx.doi.org/10.1007/s10877-016-9890-0
_version_ 1783248680628781056
author Touw, Hugo R. W.
Verheul, Milou H.
Tuinman, Pieter R.
Smit, Jeroen
Thöne, Deirdre
Schober, Patrick
Boer, Christa
author_facet Touw, Hugo R. W.
Verheul, Milou H.
Tuinman, Pieter R.
Smit, Jeroen
Thöne, Deirdre
Schober, Patrick
Boer, Christa
author_sort Touw, Hugo R. W.
collection PubMed
description The value of capnography during procedural sedation and analgesia (PSA) for the detection of hypoxaemia during upper gastrointestinal (UGI) endoscopic procedures is limited. Photoplethysmography respiratory rate (RRp) monitoring may provide a useful alternative, but the level of agreement with capnography during PSA is unknown. We therefore investigated the level of agreement between the RRp and capnography-based RR (RRc) during PSA for UGI endoscopy. This study included patients undergoing PSA for UGI endoscopy procedures. Pulse oximetry (SpO(2)) and RRc were recorded in combination with Nellcor 2.0 (RRp) monitoring (Covidien, USA). Bland–Altman analysis was used to evaluate the level of agreement between RRc and RRp. Episodes of apnoea, defined as no detection of exhaled CO(2) for minimal 36 s, and hypoxaemia, defined as an SpO(2) < 92 %, were registered. A total of 1054 min of data from 26 patients were analysed. Bland–Altman analysis between the RRc and RRp revealed a bias of 2.25 ± 5.41 breath rate per minute (brpm), with limits of agreement from −8.35 to 12.84 brpm for an RR ≥ 4 brpm. A total of 67 apnoea events were detected. In 21 % of all apnoea events, the patient became hypoxaemic. Hypoxaemia occurred 42 times with a median length of 34 (19–141) s, and was preceded in 34 % of the cases by apnoea and in 64 % by an RRc ≥ 8 brpm. In 81 % of all apnoea events, photoplethysmography registered an RRp ≥ 4 brpm. We found a low level of agreement between capnography and the plethysmography respiratory rate during procedural sedation for UGI endoscopy. Moreover, respiratory rate derived from both the capnogram and photoplethysmogram showed a limited ability to provide warning signs for a hypoxaemic event during the sedation procedure.
format Online
Article
Text
id pubmed-5500676
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-55006762017-07-21 Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy Touw, Hugo R. W. Verheul, Milou H. Tuinman, Pieter R. Smit, Jeroen Thöne, Deirdre Schober, Patrick Boer, Christa J Clin Monit Comput Original Research The value of capnography during procedural sedation and analgesia (PSA) for the detection of hypoxaemia during upper gastrointestinal (UGI) endoscopic procedures is limited. Photoplethysmography respiratory rate (RRp) monitoring may provide a useful alternative, but the level of agreement with capnography during PSA is unknown. We therefore investigated the level of agreement between the RRp and capnography-based RR (RRc) during PSA for UGI endoscopy. This study included patients undergoing PSA for UGI endoscopy procedures. Pulse oximetry (SpO(2)) and RRc were recorded in combination with Nellcor 2.0 (RRp) monitoring (Covidien, USA). Bland–Altman analysis was used to evaluate the level of agreement between RRc and RRp. Episodes of apnoea, defined as no detection of exhaled CO(2) for minimal 36 s, and hypoxaemia, defined as an SpO(2) < 92 %, were registered. A total of 1054 min of data from 26 patients were analysed. Bland–Altman analysis between the RRc and RRp revealed a bias of 2.25 ± 5.41 breath rate per minute (brpm), with limits of agreement from −8.35 to 12.84 brpm for an RR ≥ 4 brpm. A total of 67 apnoea events were detected. In 21 % of all apnoea events, the patient became hypoxaemic. Hypoxaemia occurred 42 times with a median length of 34 (19–141) s, and was preceded in 34 % of the cases by apnoea and in 64 % by an RRc ≥ 8 brpm. In 81 % of all apnoea events, photoplethysmography registered an RRp ≥ 4 brpm. We found a low level of agreement between capnography and the plethysmography respiratory rate during procedural sedation for UGI endoscopy. Moreover, respiratory rate derived from both the capnogram and photoplethysmogram showed a limited ability to provide warning signs for a hypoxaemic event during the sedation procedure. Springer Netherlands 2016-05-28 2017 /pmc/articles/PMC5500676/ /pubmed/27236561 http://dx.doi.org/10.1007/s10877-016-9890-0 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Touw, Hugo R. W.
Verheul, Milou H.
Tuinman, Pieter R.
Smit, Jeroen
Thöne, Deirdre
Schober, Patrick
Boer, Christa
Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy
title Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy
title_full Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy
title_fullStr Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy
title_full_unstemmed Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy
title_short Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy
title_sort photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5500676/
https://www.ncbi.nlm.nih.gov/pubmed/27236561
http://dx.doi.org/10.1007/s10877-016-9890-0
work_keys_str_mv AT touwhugorw photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy
AT verheulmilouh photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy
AT tuinmanpieterr photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy
AT smitjeroen photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy
AT thonedeirdre photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy
AT schoberpatrick photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy
AT boerchrista photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy