Cargando…
Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy
The value of capnography during procedural sedation and analgesia (PSA) for the detection of hypoxaemia during upper gastrointestinal (UGI) endoscopic procedures is limited. Photoplethysmography respiratory rate (RRp) monitoring may provide a useful alternative, but the level of agreement with capno...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5500676/ https://www.ncbi.nlm.nih.gov/pubmed/27236561 http://dx.doi.org/10.1007/s10877-016-9890-0 |
_version_ | 1783248680628781056 |
---|---|
author | Touw, Hugo R. W. Verheul, Milou H. Tuinman, Pieter R. Smit, Jeroen Thöne, Deirdre Schober, Patrick Boer, Christa |
author_facet | Touw, Hugo R. W. Verheul, Milou H. Tuinman, Pieter R. Smit, Jeroen Thöne, Deirdre Schober, Patrick Boer, Christa |
author_sort | Touw, Hugo R. W. |
collection | PubMed |
description | The value of capnography during procedural sedation and analgesia (PSA) for the detection of hypoxaemia during upper gastrointestinal (UGI) endoscopic procedures is limited. Photoplethysmography respiratory rate (RRp) monitoring may provide a useful alternative, but the level of agreement with capnography during PSA is unknown. We therefore investigated the level of agreement between the RRp and capnography-based RR (RRc) during PSA for UGI endoscopy. This study included patients undergoing PSA for UGI endoscopy procedures. Pulse oximetry (SpO(2)) and RRc were recorded in combination with Nellcor 2.0 (RRp) monitoring (Covidien, USA). Bland–Altman analysis was used to evaluate the level of agreement between RRc and RRp. Episodes of apnoea, defined as no detection of exhaled CO(2) for minimal 36 s, and hypoxaemia, defined as an SpO(2) < 92 %, were registered. A total of 1054 min of data from 26 patients were analysed. Bland–Altman analysis between the RRc and RRp revealed a bias of 2.25 ± 5.41 breath rate per minute (brpm), with limits of agreement from −8.35 to 12.84 brpm for an RR ≥ 4 brpm. A total of 67 apnoea events were detected. In 21 % of all apnoea events, the patient became hypoxaemic. Hypoxaemia occurred 42 times with a median length of 34 (19–141) s, and was preceded in 34 % of the cases by apnoea and in 64 % by an RRc ≥ 8 brpm. In 81 % of all apnoea events, photoplethysmography registered an RRp ≥ 4 brpm. We found a low level of agreement between capnography and the plethysmography respiratory rate during procedural sedation for UGI endoscopy. Moreover, respiratory rate derived from both the capnogram and photoplethysmogram showed a limited ability to provide warning signs for a hypoxaemic event during the sedation procedure. |
format | Online Article Text |
id | pubmed-5500676 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-55006762017-07-21 Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy Touw, Hugo R. W. Verheul, Milou H. Tuinman, Pieter R. Smit, Jeroen Thöne, Deirdre Schober, Patrick Boer, Christa J Clin Monit Comput Original Research The value of capnography during procedural sedation and analgesia (PSA) for the detection of hypoxaemia during upper gastrointestinal (UGI) endoscopic procedures is limited. Photoplethysmography respiratory rate (RRp) monitoring may provide a useful alternative, but the level of agreement with capnography during PSA is unknown. We therefore investigated the level of agreement between the RRp and capnography-based RR (RRc) during PSA for UGI endoscopy. This study included patients undergoing PSA for UGI endoscopy procedures. Pulse oximetry (SpO(2)) and RRc were recorded in combination with Nellcor 2.0 (RRp) monitoring (Covidien, USA). Bland–Altman analysis was used to evaluate the level of agreement between RRc and RRp. Episodes of apnoea, defined as no detection of exhaled CO(2) for minimal 36 s, and hypoxaemia, defined as an SpO(2) < 92 %, were registered. A total of 1054 min of data from 26 patients were analysed. Bland–Altman analysis between the RRc and RRp revealed a bias of 2.25 ± 5.41 breath rate per minute (brpm), with limits of agreement from −8.35 to 12.84 brpm for an RR ≥ 4 brpm. A total of 67 apnoea events were detected. In 21 % of all apnoea events, the patient became hypoxaemic. Hypoxaemia occurred 42 times with a median length of 34 (19–141) s, and was preceded in 34 % of the cases by apnoea and in 64 % by an RRc ≥ 8 brpm. In 81 % of all apnoea events, photoplethysmography registered an RRp ≥ 4 brpm. We found a low level of agreement between capnography and the plethysmography respiratory rate during procedural sedation for UGI endoscopy. Moreover, respiratory rate derived from both the capnogram and photoplethysmogram showed a limited ability to provide warning signs for a hypoxaemic event during the sedation procedure. Springer Netherlands 2016-05-28 2017 /pmc/articles/PMC5500676/ /pubmed/27236561 http://dx.doi.org/10.1007/s10877-016-9890-0 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research Touw, Hugo R. W. Verheul, Milou H. Tuinman, Pieter R. Smit, Jeroen Thöne, Deirdre Schober, Patrick Boer, Christa Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy |
title | Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy |
title_full | Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy |
title_fullStr | Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy |
title_full_unstemmed | Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy |
title_short | Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy |
title_sort | photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5500676/ https://www.ncbi.nlm.nih.gov/pubmed/27236561 http://dx.doi.org/10.1007/s10877-016-9890-0 |
work_keys_str_mv | AT touwhugorw photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy AT verheulmilouh photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy AT tuinmanpieterr photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy AT smitjeroen photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy AT thonedeirdre photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy AT schoberpatrick photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy AT boerchrista photoplethysmographyrespiratoryratemonitoringinpatientsreceivingproceduralsedationandanalgesiaforuppergastrointestinalendoscopy |