Effect of room temperature on tests for diagnosing vibration-induced white finger: finger rewarming times and finger systolic blood pressures

PURPOSE: This study investigates the effects of room temperature on two standard tests used to assist the diagnosis of vibration-induced white finger (VWF): finger rewarming times and finger systolic blood pressures. METHODS: Twelve healthy males and twelve healthy females participated in four sessi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ye, Ying, Griffin, Michael J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5500685/
https://www.ncbi.nlm.nih.gov/pubmed/28353018
http://dx.doi.org/10.1007/s00420-017-1214-2
Descripción
Sumario:PURPOSE: This study investigates the effects of room temperature on two standard tests used to assist the diagnosis of vibration-induced white finger (VWF): finger rewarming times and finger systolic blood pressures. METHODS: Twelve healthy males and twelve healthy females participated in four sessions to obtain either finger skin temperatures (FSTs) during cooling and rewarming of the hand or finger systolic blood pressures (FSBPs) after local cooling of the fingers to 15 and 10 °C. The measures were obtained with the room temperature at either 20 or 28 °C. RESULTS: There were lower baseline finger skin temperatures, longer finger rewarming times, and lower finger systolic blood pressures with the room temperature at 20 than 28 °C. However, percentage reductions in FSBP at 15 and 10 °C relative to 30 °C (i.e. %FSBP) did not differ between the two room temperatures. Females had lower baseline FSTs, longer rewarming times, and lower FSBPs than males, but %FSBPs were similar in males and females. CONCLUSIONS: Finger rewarming times after cold provocation are heavily influenced by room temperature and gender. For evaluating peripheral circulatory function using finger rewarming times, the room temperature must be strictly controlled, and a different diagnostic criterion is required for females. The calculation of percentage changes in finger systolic blood pressure at 15 and 10 °C relative to 30 °C reduces effects of both room temperature and gender, and the test may be used in conditions where the ±1 °C tolerance on room temperature required by the current standard cannot be achieved.