Cargando…

Comparative analysis of Luminex-based donor-specific antibody mean fluorescence intensity values with complement-dependent cytotoxicity & flow crossmatch results in live donor renal transplantation

BACKGROUND & OBJECTIVES: Antibodies specific to donor human leucocyte antigen (HLA) play a critical role in graft rejection and graft loss. In recent years, techniques for their detection have evolved significantly providing an ever-increasing degree of sensitivity and specificity, from the conv...

Descripción completa

Detalles Bibliográficos
Autores principales: Baranwal, Ajay Kumar, Bhat, Deepali Krishan, Goswami, Sanjeev, Agarwal, Sanjay Kumar, Kaur, Gurvinder, Kaur, Jasmeet, Mehra, Narinder
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5501055/
https://www.ncbi.nlm.nih.gov/pubmed/28639599
http://dx.doi.org/10.4103/ijmr.IJMR_222_16
_version_ 1783248741439897600
author Baranwal, Ajay Kumar
Bhat, Deepali Krishan
Goswami, Sanjeev
Agarwal, Sanjay Kumar
Kaur, Gurvinder
Kaur, Jasmeet
Mehra, Narinder
author_facet Baranwal, Ajay Kumar
Bhat, Deepali Krishan
Goswami, Sanjeev
Agarwal, Sanjay Kumar
Kaur, Gurvinder
Kaur, Jasmeet
Mehra, Narinder
author_sort Baranwal, Ajay Kumar
collection PubMed
description BACKGROUND & OBJECTIVES: Antibodies specific to donor human leucocyte antigen (HLA) play a critical role in graft rejection and graft loss. In recent years, techniques for their detection have evolved significantly providing an ever-increasing degree of sensitivity and specificity, from the conventional cell-based assays to the advanced solid-phase system based on the Luminex platform. Consensus is still evolving on the routine employment of all these methods, either stand alone or in combination. The objective of this study was to explore the near-accurate mean fluorescence intensity (MFI) cut-off values detected on Luminex platform predicting the strength of cell-based crossmatch results. METHODS: Serum samples from 116 primary renal transplant recipients awaiting transplantation were tested for the presence of antidonor antibodies by the complement-dependent cytotoxicity (CDC) and flow crossmatch (FCXM) methods with their corresponding donors as well as for HLA-donor-specific antibodies (DSA) detection using a sensitive single antigen bead (SAB) assay. RESULTS: None of the patients having HLA Class I DSA with MFI values <1000 showed positivity for T-cell FCXM or CDC crossmatch, while in the group having MFI values between 1000 and 3000, 54 per cent showed positivity for the FCXM but none by the CDC method. However, in the group having MFI values >3000, 95 per cent of cases were positive for FCXM. Further, those groups with MFI values between 3000 and 5000, only 36 per cent were positive for CDC crossmatch, while 90 per cent showed positivity in the group with MFI >7000. INTERPRETATION & CONCLUSIONS: A cut-off MFI value of 3000 for Luminex SAB-based assay was found to significantly correlate with the FCXM positivity while a MFI value of 7000 and above predicted a positive CDC crossmatch. MFI cut-off value obtained as a surrogate marker for CDC and FCXM tests will help in resolving the limitations of different cell-based techniques.
format Online
Article
Text
id pubmed-5501055
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-55010552017-07-13 Comparative analysis of Luminex-based donor-specific antibody mean fluorescence intensity values with complement-dependent cytotoxicity & flow crossmatch results in live donor renal transplantation Baranwal, Ajay Kumar Bhat, Deepali Krishan Goswami, Sanjeev Agarwal, Sanjay Kumar Kaur, Gurvinder Kaur, Jasmeet Mehra, Narinder Indian J Med Res Original Article BACKGROUND & OBJECTIVES: Antibodies specific to donor human leucocyte antigen (HLA) play a critical role in graft rejection and graft loss. In recent years, techniques for their detection have evolved significantly providing an ever-increasing degree of sensitivity and specificity, from the conventional cell-based assays to the advanced solid-phase system based on the Luminex platform. Consensus is still evolving on the routine employment of all these methods, either stand alone or in combination. The objective of this study was to explore the near-accurate mean fluorescence intensity (MFI) cut-off values detected on Luminex platform predicting the strength of cell-based crossmatch results. METHODS: Serum samples from 116 primary renal transplant recipients awaiting transplantation were tested for the presence of antidonor antibodies by the complement-dependent cytotoxicity (CDC) and flow crossmatch (FCXM) methods with their corresponding donors as well as for HLA-donor-specific antibodies (DSA) detection using a sensitive single antigen bead (SAB) assay. RESULTS: None of the patients having HLA Class I DSA with MFI values <1000 showed positivity for T-cell FCXM or CDC crossmatch, while in the group having MFI values between 1000 and 3000, 54 per cent showed positivity for the FCXM but none by the CDC method. However, in the group having MFI values >3000, 95 per cent of cases were positive for FCXM. Further, those groups with MFI values between 3000 and 5000, only 36 per cent were positive for CDC crossmatch, while 90 per cent showed positivity in the group with MFI >7000. INTERPRETATION & CONCLUSIONS: A cut-off MFI value of 3000 for Luminex SAB-based assay was found to significantly correlate with the FCXM positivity while a MFI value of 7000 and above predicted a positive CDC crossmatch. MFI cut-off value obtained as a surrogate marker for CDC and FCXM tests will help in resolving the limitations of different cell-based techniques. Medknow Publications & Media Pvt Ltd 2017-02 /pmc/articles/PMC5501055/ /pubmed/28639599 http://dx.doi.org/10.4103/ijmr.IJMR_222_16 Text en Copyright: © 2017 Indian Journal of Medical Research http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Baranwal, Ajay Kumar
Bhat, Deepali Krishan
Goswami, Sanjeev
Agarwal, Sanjay Kumar
Kaur, Gurvinder
Kaur, Jasmeet
Mehra, Narinder
Comparative analysis of Luminex-based donor-specific antibody mean fluorescence intensity values with complement-dependent cytotoxicity & flow crossmatch results in live donor renal transplantation
title Comparative analysis of Luminex-based donor-specific antibody mean fluorescence intensity values with complement-dependent cytotoxicity & flow crossmatch results in live donor renal transplantation
title_full Comparative analysis of Luminex-based donor-specific antibody mean fluorescence intensity values with complement-dependent cytotoxicity & flow crossmatch results in live donor renal transplantation
title_fullStr Comparative analysis of Luminex-based donor-specific antibody mean fluorescence intensity values with complement-dependent cytotoxicity & flow crossmatch results in live donor renal transplantation
title_full_unstemmed Comparative analysis of Luminex-based donor-specific antibody mean fluorescence intensity values with complement-dependent cytotoxicity & flow crossmatch results in live donor renal transplantation
title_short Comparative analysis of Luminex-based donor-specific antibody mean fluorescence intensity values with complement-dependent cytotoxicity & flow crossmatch results in live donor renal transplantation
title_sort comparative analysis of luminex-based donor-specific antibody mean fluorescence intensity values with complement-dependent cytotoxicity & flow crossmatch results in live donor renal transplantation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5501055/
https://www.ncbi.nlm.nih.gov/pubmed/28639599
http://dx.doi.org/10.4103/ijmr.IJMR_222_16
work_keys_str_mv AT baranwalajaykumar comparativeanalysisofluminexbaseddonorspecificantibodymeanfluorescenceintensityvalueswithcomplementdependentcytotoxicityflowcrossmatchresultsinlivedonorrenaltransplantation
AT bhatdeepalikrishan comparativeanalysisofluminexbaseddonorspecificantibodymeanfluorescenceintensityvalueswithcomplementdependentcytotoxicityflowcrossmatchresultsinlivedonorrenaltransplantation
AT goswamisanjeev comparativeanalysisofluminexbaseddonorspecificantibodymeanfluorescenceintensityvalueswithcomplementdependentcytotoxicityflowcrossmatchresultsinlivedonorrenaltransplantation
AT agarwalsanjaykumar comparativeanalysisofluminexbaseddonorspecificantibodymeanfluorescenceintensityvalueswithcomplementdependentcytotoxicityflowcrossmatchresultsinlivedonorrenaltransplantation
AT kaurgurvinder comparativeanalysisofluminexbaseddonorspecificantibodymeanfluorescenceintensityvalueswithcomplementdependentcytotoxicityflowcrossmatchresultsinlivedonorrenaltransplantation
AT kaurjasmeet comparativeanalysisofluminexbaseddonorspecificantibodymeanfluorescenceintensityvalueswithcomplementdependentcytotoxicityflowcrossmatchresultsinlivedonorrenaltransplantation
AT mehranarinder comparativeanalysisofluminexbaseddonorspecificantibodymeanfluorescenceintensityvalueswithcomplementdependentcytotoxicityflowcrossmatchresultsinlivedonorrenaltransplantation