Cargando…
Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model
INTRODUCTION: Removal of pulmonary secretions in mechanically ventilated patients usually requires suction with closed catheter systems or flexible bronchoscopes. Manual ventilation is occasionally performed during such procedures if clinicians suspect inadequate ventilation. Suctioning can also be...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Open Respiratory Research
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5501241/ https://www.ncbi.nlm.nih.gov/pubmed/28725445 http://dx.doi.org/10.1136/bmjresp-2016-000176 |
_version_ | 1783248763200995328 |
---|---|
author | Nakstad, Espen Rostrup Opdahl, Helge Heyerdahl, Fridtjof Borchsenius, Fredrik Skjønsberg, Ole Henning |
author_facet | Nakstad, Espen Rostrup Opdahl, Helge Heyerdahl, Fridtjof Borchsenius, Fredrik Skjønsberg, Ole Henning |
author_sort | Nakstad, Espen Rostrup |
collection | PubMed |
description | INTRODUCTION: Removal of pulmonary secretions in mechanically ventilated patients usually requires suction with closed catheter systems or flexible bronchoscopes. Manual ventilation is occasionally performed during such procedures if clinicians suspect inadequate ventilation. Suctioning can also be performed with the ventilator entirely disconnected from the endotracheal tube (ETT). The aim of this study was to investigate if these two procedures generate negative airway pressures, which may contribute to atelectasis. METHODS: The effects of device insertion and suctioning in ETTs were examined in a mechanical lung model with a pressure transducer inserted distal to ETTs of 9 mm, 8 mm and 7 mm internal diameter (ID). A 16 Fr bronchoscope and 12, 14 and 16 Fr suction catheters were used at two different vacuum levels during manual ventilation and with the ETTs disconnected. RESULTS: During manual ventilation with ETTs of 9 mm, 8 mm and 7 mm ID, and bronchoscopic suctioning at moderate suction level, peak pressure (P(PEAK)) dropped from 23, 22 and 24.5 cm H(2)O to 16, 16 and 15 cm H(2)O, respectively. Maximum suction reduced P(PEAK) to 20, 17 and 11 cm H(2)O, respectively, and the end-expiratory pressure fell from 5, 5.5 and 4.5 cm H(2)O to –2, –6 and –17 cm H(2)O. Suctioning through disconnected ETTs (open suction procedure) gave negative model airway pressures throughout the duration of the procedures. CONCLUSIONS: Manual ventilation and open suction procedures induce negative end-expiratory pressure during endotracheal suctioning, which may have clinical implications in patients who need high PEEP (positive end-expiratory pressure). |
format | Online Article Text |
id | pubmed-5501241 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BMJ Open Respiratory Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-55012412017-07-19 Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model Nakstad, Espen Rostrup Opdahl, Helge Heyerdahl, Fridtjof Borchsenius, Fredrik Skjønsberg, Ole Henning BMJ Open Respir Res Respiratory Research INTRODUCTION: Removal of pulmonary secretions in mechanically ventilated patients usually requires suction with closed catheter systems or flexible bronchoscopes. Manual ventilation is occasionally performed during such procedures if clinicians suspect inadequate ventilation. Suctioning can also be performed with the ventilator entirely disconnected from the endotracheal tube (ETT). The aim of this study was to investigate if these two procedures generate negative airway pressures, which may contribute to atelectasis. METHODS: The effects of device insertion and suctioning in ETTs were examined in a mechanical lung model with a pressure transducer inserted distal to ETTs of 9 mm, 8 mm and 7 mm internal diameter (ID). A 16 Fr bronchoscope and 12, 14 and 16 Fr suction catheters were used at two different vacuum levels during manual ventilation and with the ETTs disconnected. RESULTS: During manual ventilation with ETTs of 9 mm, 8 mm and 7 mm ID, and bronchoscopic suctioning at moderate suction level, peak pressure (P(PEAK)) dropped from 23, 22 and 24.5 cm H(2)O to 16, 16 and 15 cm H(2)O, respectively. Maximum suction reduced P(PEAK) to 20, 17 and 11 cm H(2)O, respectively, and the end-expiratory pressure fell from 5, 5.5 and 4.5 cm H(2)O to –2, –6 and –17 cm H(2)O. Suctioning through disconnected ETTs (open suction procedure) gave negative model airway pressures throughout the duration of the procedures. CONCLUSIONS: Manual ventilation and open suction procedures induce negative end-expiratory pressure during endotracheal suctioning, which may have clinical implications in patients who need high PEEP (positive end-expiratory pressure). BMJ Open Respiratory Research 2017-05-08 /pmc/articles/PMC5501241/ /pubmed/28725445 http://dx.doi.org/10.1136/bmjresp-2016-000176 Text en © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
spellingShingle | Respiratory Research Nakstad, Espen Rostrup Opdahl, Helge Heyerdahl, Fridtjof Borchsenius, Fredrik Skjønsberg, Ole Henning Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model |
title | Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model |
title_full | Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model |
title_fullStr | Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model |
title_full_unstemmed | Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model |
title_short | Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model |
title_sort | manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model |
topic | Respiratory Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5501241/ https://www.ncbi.nlm.nih.gov/pubmed/28725445 http://dx.doi.org/10.1136/bmjresp-2016-000176 |
work_keys_str_mv | AT nakstadespenrostrup manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel AT opdahlhelge manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel AT heyerdahlfridtjof manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel AT borchseniusfredrik manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel AT skjønsbergolehenning manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel |