Cargando…

Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model

INTRODUCTION: Removal of pulmonary secretions in mechanically ventilated patients usually requires suction with closed catheter systems or flexible bronchoscopes. Manual ventilation is occasionally performed during such procedures if clinicians suspect inadequate ventilation. Suctioning can also be...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakstad, Espen Rostrup, Opdahl, Helge, Heyerdahl, Fridtjof, Borchsenius, Fredrik, Skjønsberg, Ole Henning
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Open Respiratory Research 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5501241/
https://www.ncbi.nlm.nih.gov/pubmed/28725445
http://dx.doi.org/10.1136/bmjresp-2016-000176
_version_ 1783248763200995328
author Nakstad, Espen Rostrup
Opdahl, Helge
Heyerdahl, Fridtjof
Borchsenius, Fredrik
Skjønsberg, Ole Henning
author_facet Nakstad, Espen Rostrup
Opdahl, Helge
Heyerdahl, Fridtjof
Borchsenius, Fredrik
Skjønsberg, Ole Henning
author_sort Nakstad, Espen Rostrup
collection PubMed
description INTRODUCTION: Removal of pulmonary secretions in mechanically ventilated patients usually requires suction with closed catheter systems or flexible bronchoscopes. Manual ventilation is occasionally performed during such procedures if clinicians suspect inadequate ventilation. Suctioning can also be performed with the ventilator entirely disconnected from the endotracheal tube (ETT). The aim of this study was to investigate if these two procedures generate negative airway pressures, which may contribute to atelectasis. METHODS: The effects of device insertion and suctioning in ETTs were examined in a mechanical lung model with a pressure transducer inserted distal to ETTs of 9 mm, 8 mm and 7 mm internal diameter (ID). A 16 Fr bronchoscope and 12, 14 and 16 Fr suction catheters were used at two different vacuum levels during manual ventilation and with the ETTs disconnected. RESULTS: During manual ventilation with ETTs of 9 mm, 8 mm and 7 mm ID, and bronchoscopic suctioning at moderate suction level, peak pressure (P(PEAK)) dropped from 23, 22 and 24.5 cm H(2)O to 16, 16 and 15 cm H(2)O, respectively. Maximum suction reduced P(PEAK) to 20, 17 and 11 cm H(2)O, respectively, and the end-expiratory pressure fell from 5, 5.5 and 4.5 cm H(2)O to –2, –6 and –17 cm H(2)O. Suctioning through disconnected ETTs (open suction procedure) gave negative model airway pressures throughout the duration of the procedures. CONCLUSIONS: Manual ventilation and open suction procedures induce negative end-expiratory pressure during endotracheal suctioning, which may have clinical implications in patients who need high PEEP (positive end-expiratory pressure).
format Online
Article
Text
id pubmed-5501241
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BMJ Open Respiratory Research
record_format MEDLINE/PubMed
spelling pubmed-55012412017-07-19 Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model Nakstad, Espen Rostrup Opdahl, Helge Heyerdahl, Fridtjof Borchsenius, Fredrik Skjønsberg, Ole Henning BMJ Open Respir Res Respiratory Research INTRODUCTION: Removal of pulmonary secretions in mechanically ventilated patients usually requires suction with closed catheter systems or flexible bronchoscopes. Manual ventilation is occasionally performed during such procedures if clinicians suspect inadequate ventilation. Suctioning can also be performed with the ventilator entirely disconnected from the endotracheal tube (ETT). The aim of this study was to investigate if these two procedures generate negative airway pressures, which may contribute to atelectasis. METHODS: The effects of device insertion and suctioning in ETTs were examined in a mechanical lung model with a pressure transducer inserted distal to ETTs of 9 mm, 8 mm and 7 mm internal diameter (ID). A 16 Fr bronchoscope and 12, 14 and 16 Fr suction catheters were used at two different vacuum levels during manual ventilation and with the ETTs disconnected. RESULTS: During manual ventilation with ETTs of 9 mm, 8 mm and 7 mm ID, and bronchoscopic suctioning at moderate suction level, peak pressure (P(PEAK)) dropped from 23, 22 and 24.5 cm H(2)O to 16, 16 and 15 cm H(2)O, respectively. Maximum suction reduced P(PEAK) to 20, 17 and 11 cm H(2)O, respectively, and the end-expiratory pressure fell from 5, 5.5 and 4.5 cm H(2)O to –2, –6 and –17 cm H(2)O. Suctioning through disconnected ETTs (open suction procedure) gave negative model airway pressures throughout the duration of the procedures. CONCLUSIONS: Manual ventilation and open suction procedures induce negative end-expiratory pressure during endotracheal suctioning, which may have clinical implications in patients who need high PEEP (positive end-expiratory pressure). BMJ Open Respiratory Research 2017-05-08 /pmc/articles/PMC5501241/ /pubmed/28725445 http://dx.doi.org/10.1136/bmjresp-2016-000176 Text en © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Respiratory Research
Nakstad, Espen Rostrup
Opdahl, Helge
Heyerdahl, Fridtjof
Borchsenius, Fredrik
Skjønsberg, Ole Henning
Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model
title Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model
title_full Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model
title_fullStr Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model
title_full_unstemmed Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model
title_short Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model
title_sort manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model
topic Respiratory Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5501241/
https://www.ncbi.nlm.nih.gov/pubmed/28725445
http://dx.doi.org/10.1136/bmjresp-2016-000176
work_keys_str_mv AT nakstadespenrostrup manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel
AT opdahlhelge manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel
AT heyerdahlfridtjof manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel
AT borchseniusfredrik manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel
AT skjønsbergolehenning manualventilationandopensuctionprocedurescontributetonegativepressuresinamechanicallungmodel