Fibrous encapsulation of the peritoneal catheter in peritoneal shunt: Case report

BACKGROUND: The authors report a case of fibrous encapsulation of the peritoneal catheter, which caused peritoneal shunt malfunction, and has not previously been researched well as a complication of peritoneal shunts. CASE DESCRIPTION: A 69-year-old woman who had undergone a lumboperitoneal (LP) shu...

Descripción completa

Detalles Bibliográficos
Autores principales: Kano, Tomoaki, Kawauchi, Hideyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5502295/
https://www.ncbi.nlm.nih.gov/pubmed/28713635
http://dx.doi.org/10.4103/sni.sni_420_16
_version_ 1783248928121028608
author Kano, Tomoaki
Kawauchi, Hideyuki
author_facet Kano, Tomoaki
Kawauchi, Hideyuki
author_sort Kano, Tomoaki
collection PubMed
description BACKGROUND: The authors report a case of fibrous encapsulation of the peritoneal catheter, which caused peritoneal shunt malfunction, and has not previously been researched well as a complication of peritoneal shunts. CASE DESCRIPTION: A 69-year-old woman who had undergone a lumboperitoneal (LP) shunt for communicative hydrocephalus following subarachnoid hemorrhage caused by a ruptured aneurysm was identified with malfunction of the LP shunt system by dementia and gait disturbance. Hydrocephalus was revealed on computed tomography (CT). Under a laparoscopy, the intraabdominal peritoneal catheter was observed to be obstructed by fibrous encapsulation covering it like a long white stocking. Although the fibrous encapsulating tissue was excised by laparoscopy forceps, a ventriculoperitoneal shunt device was replaced with a new peritoneal catheter. The histopathological diagnosis of the surgically resected encapsulating tissue was the fibrous tissue with a few inflammation cells and a layer of lining cells surrounding some part of it. In the immunohistochemical study, a layer of lining cells surrounding the fibrous tissue showed immunohistochemically positive staining for calretinin. CONCLUSION: The fibrous encapsulation would be formed by peritoneal reaction to a peritoneal catheter as a foreign body by these histopathological and immunohistochemical analyses.
format Online
Article
Text
id pubmed-5502295
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-55022952017-07-14 Fibrous encapsulation of the peritoneal catheter in peritoneal shunt: Case report Kano, Tomoaki Kawauchi, Hideyuki Surg Neurol Int Pediatric Neurosurgery: Case Report BACKGROUND: The authors report a case of fibrous encapsulation of the peritoneal catheter, which caused peritoneal shunt malfunction, and has not previously been researched well as a complication of peritoneal shunts. CASE DESCRIPTION: A 69-year-old woman who had undergone a lumboperitoneal (LP) shunt for communicative hydrocephalus following subarachnoid hemorrhage caused by a ruptured aneurysm was identified with malfunction of the LP shunt system by dementia and gait disturbance. Hydrocephalus was revealed on computed tomography (CT). Under a laparoscopy, the intraabdominal peritoneal catheter was observed to be obstructed by fibrous encapsulation covering it like a long white stocking. Although the fibrous encapsulating tissue was excised by laparoscopy forceps, a ventriculoperitoneal shunt device was replaced with a new peritoneal catheter. The histopathological diagnosis of the surgically resected encapsulating tissue was the fibrous tissue with a few inflammation cells and a layer of lining cells surrounding some part of it. In the immunohistochemical study, a layer of lining cells surrounding the fibrous tissue showed immunohistochemically positive staining for calretinin. CONCLUSION: The fibrous encapsulation would be formed by peritoneal reaction to a peritoneal catheter as a foreign body by these histopathological and immunohistochemical analyses. Medknow Publications & Media Pvt Ltd 2017-06-27 /pmc/articles/PMC5502295/ /pubmed/28713635 http://dx.doi.org/10.4103/sni.sni_420_16 Text en Copyright: © 2017 Surgical Neurology International http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Pediatric Neurosurgery: Case Report
Kano, Tomoaki
Kawauchi, Hideyuki
Fibrous encapsulation of the peritoneal catheter in peritoneal shunt: Case report
title Fibrous encapsulation of the peritoneal catheter in peritoneal shunt: Case report
title_full Fibrous encapsulation of the peritoneal catheter in peritoneal shunt: Case report
title_fullStr Fibrous encapsulation of the peritoneal catheter in peritoneal shunt: Case report
title_full_unstemmed Fibrous encapsulation of the peritoneal catheter in peritoneal shunt: Case report
title_short Fibrous encapsulation of the peritoneal catheter in peritoneal shunt: Case report
title_sort fibrous encapsulation of the peritoneal catheter in peritoneal shunt: case report
topic Pediatric Neurosurgery: Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5502295/
https://www.ncbi.nlm.nih.gov/pubmed/28713635
http://dx.doi.org/10.4103/sni.sni_420_16
work_keys_str_mv AT kanotomoaki fibrousencapsulationoftheperitonealcatheterinperitonealshuntcasereport
AT kawauchihideyuki fibrousencapsulationoftheperitonealcatheterinperitonealshuntcasereport