Cargando…

Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files

OBJECTIVES: To compare the dimensions of gutta-percha (GP) cones of ProTaper Next (25/0.06) and WaveOne (25/0.08) in relation to their corresponding instruments of the same dimension, respectively. MATERIALS AND METHODS: Two groups of GP cones were made with 25 cones in each group. Group 1 consisted...

Descripción completa

Detalles Bibliográficos
Autores principales: Bajaj, Nitika, Monga, Prashant, Mahajan, Pardeep
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5502565/
https://www.ncbi.nlm.nih.gov/pubmed/28729793
http://dx.doi.org/10.4103/ejd.ejd_167_16
_version_ 1783248974373715968
author Bajaj, Nitika
Monga, Prashant
Mahajan, Pardeep
author_facet Bajaj, Nitika
Monga, Prashant
Mahajan, Pardeep
author_sort Bajaj, Nitika
collection PubMed
description OBJECTIVES: To compare the dimensions of gutta-percha (GP) cones of ProTaper Next (25/0.06) and WaveOne (25/0.08) in relation to their corresponding instruments of the same dimension, respectively. MATERIALS AND METHODS: Two groups of GP cones were made with 25 cones in each group. Group 1 consisted of 25 GP cones # 25/0.06 (ProTaper Next). Group 2 consisted of 25 GP cones # 25/0.08 (WaveOne). Measurements were done at D1 (1 mm short of the tip), D3 (3 mm short of the tip), and D11 (11 mm short of the tip) for GP cones of both groups and were compared with their corresponding instruments. RESULTS: Group 1 (ProTaper) 25/.06 GP points showed greater diameters than those of the corresponding instrument, which was statistically significant. Group 2 (WaveOne) 25/0.08 GP points showed greater diameters than those of the corresponding instrument which was statistically significant whereas it was nonsignificant at level D1. CONCLUSION: Diameters of both ProTaper Next and WaveOne GP cones were greater than their corresponding instruments. Hence, there are chances of under obturation with both systems.
format Online
Article
Text
id pubmed-5502565
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-55025652017-07-20 Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files Bajaj, Nitika Monga, Prashant Mahajan, Pardeep Eur J Dent Original Article OBJECTIVES: To compare the dimensions of gutta-percha (GP) cones of ProTaper Next (25/0.06) and WaveOne (25/0.08) in relation to their corresponding instruments of the same dimension, respectively. MATERIALS AND METHODS: Two groups of GP cones were made with 25 cones in each group. Group 1 consisted of 25 GP cones # 25/0.06 (ProTaper Next). Group 2 consisted of 25 GP cones # 25/0.08 (WaveOne). Measurements were done at D1 (1 mm short of the tip), D3 (3 mm short of the tip), and D11 (11 mm short of the tip) for GP cones of both groups and were compared with their corresponding instruments. RESULTS: Group 1 (ProTaper) 25/.06 GP points showed greater diameters than those of the corresponding instrument, which was statistically significant. Group 2 (WaveOne) 25/0.08 GP points showed greater diameters than those of the corresponding instrument which was statistically significant whereas it was nonsignificant at level D1. CONCLUSION: Diameters of both ProTaper Next and WaveOne GP cones were greater than their corresponding instruments. Hence, there are chances of under obturation with both systems. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5502565/ /pubmed/28729793 http://dx.doi.org/10.4103/ejd.ejd_167_16 Text en Copyright: © 2017 European Journal of Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Bajaj, Nitika
Monga, Prashant
Mahajan, Pardeep
Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files
title Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files
title_full Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files
title_fullStr Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files
title_full_unstemmed Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files
title_short Assessment of consistency in the dimension of gutta-percha cones of ProTaper Next and WaveOne with their corresponding number files
title_sort assessment of consistency in the dimension of gutta-percha cones of protaper next and waveone with their corresponding number files
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5502565/
https://www.ncbi.nlm.nih.gov/pubmed/28729793
http://dx.doi.org/10.4103/ejd.ejd_167_16
work_keys_str_mv AT bajajnitika assessmentofconsistencyinthedimensionofguttaperchaconesofprotapernextandwaveonewiththeircorrespondingnumberfiles
AT mongaprashant assessmentofconsistencyinthedimensionofguttaperchaconesofprotapernextandwaveonewiththeircorrespondingnumberfiles
AT mahajanpardeep assessmentofconsistencyinthedimensionofguttaperchaconesofprotapernextandwaveonewiththeircorrespondingnumberfiles