Cargando…

Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test

BACKGROUND/AIMS: Balloon expulsion test (BET) is regarded as a screening tool of dyssynergic defecation (DD). However, some patients with normal BET results may be treated effectively by biofeedback training. This study aims to validate BET as a single screening test. METHODS: Two hundred and thirty...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jooyoung, Hong, Kyoung Sup, Kim, Joo Sung, Jung, Hyun Chae
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Neurogastroenterology and Motility 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5503295/
https://www.ncbi.nlm.nih.gov/pubmed/28578564
http://dx.doi.org/10.5056/jnm16158
_version_ 1783249074557812736
author Lee, Jooyoung
Hong, Kyoung Sup
Kim, Joo Sung
Jung, Hyun Chae
author_facet Lee, Jooyoung
Hong, Kyoung Sup
Kim, Joo Sung
Jung, Hyun Chae
author_sort Lee, Jooyoung
collection PubMed
description BACKGROUND/AIMS: Balloon expulsion test (BET) is regarded as a screening tool of dyssynergic defecation (DD). However, some patients with normal BET results may be treated effectively by biofeedback training. This study aims to validate BET as a single screening test. METHODS: Two hundred and thirty-two patients who were diagnosed with functional constipation or irritable bowel syndrome with constipation who underwent anorectal manometry (ARM) and BET at Seoul National University Hospital were enrolled. We evaluated the validity of BET based on ARM and electromyography (EMG) during biofeedback training. RESULTS: If BET ≤ 1 minute was defined as normal, sensitivity and negative predictive value (NPV) of BET in predicting paradoxical contraction based on ARM findings were 71.4% and 13.9%. If BET ≤ 3 minutes was defined as normal, sensitivity and NPV were 35.2% and 6.6%. Specificity and positive predictive value (PPV) of BET ≤ 3 minutes criteria were 84.8% and 93.3%. Same analysis was conducted in 107 patients who underwent EMG during biofeedback training. With 1-minute criteria, sensitivity and NPV of BET were 70.3% and 14.3%. With 3 minutes criteria, sensitivity and NPV of BET was 38.6% and 8.8%. Specificity and positive predictive values were both 100.0%. CONCLUSIONS: Based on either ARM or EMG during biofeedback training, sensitivity was at most 71.4% and NPV was less than 15.0% irrespective of whether BET was within 1minute or within 3 minutes. BET seems to have a limitation as both a screening test for dyssynergic defecation and a simple assessment to rule out the necessity of biofeedback training.
format Online
Article
Text
id pubmed-5503295
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Korean Society of Neurogastroenterology and Motility
record_format MEDLINE/PubMed
spelling pubmed-55032952017-07-12 Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test Lee, Jooyoung Hong, Kyoung Sup Kim, Joo Sung Jung, Hyun Chae J Neurogastroenterol Motil Original Article BACKGROUND/AIMS: Balloon expulsion test (BET) is regarded as a screening tool of dyssynergic defecation (DD). However, some patients with normal BET results may be treated effectively by biofeedback training. This study aims to validate BET as a single screening test. METHODS: Two hundred and thirty-two patients who were diagnosed with functional constipation or irritable bowel syndrome with constipation who underwent anorectal manometry (ARM) and BET at Seoul National University Hospital were enrolled. We evaluated the validity of BET based on ARM and electromyography (EMG) during biofeedback training. RESULTS: If BET ≤ 1 minute was defined as normal, sensitivity and negative predictive value (NPV) of BET in predicting paradoxical contraction based on ARM findings were 71.4% and 13.9%. If BET ≤ 3 minutes was defined as normal, sensitivity and NPV were 35.2% and 6.6%. Specificity and positive predictive value (PPV) of BET ≤ 3 minutes criteria were 84.8% and 93.3%. Same analysis was conducted in 107 patients who underwent EMG during biofeedback training. With 1-minute criteria, sensitivity and NPV of BET were 70.3% and 14.3%. With 3 minutes criteria, sensitivity and NPV of BET was 38.6% and 8.8%. Specificity and positive predictive values were both 100.0%. CONCLUSIONS: Based on either ARM or EMG during biofeedback training, sensitivity was at most 71.4% and NPV was less than 15.0% irrespective of whether BET was within 1minute or within 3 minutes. BET seems to have a limitation as both a screening test for dyssynergic defecation and a simple assessment to rule out the necessity of biofeedback training. Korean Society of Neurogastroenterology and Motility 2017-07 2017-07-01 /pmc/articles/PMC5503295/ /pubmed/28578564 http://dx.doi.org/10.5056/jnm16158 Text en © 2017 The Korean Society of Neurogastroenterology and Motility This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Jooyoung
Hong, Kyoung Sup
Kim, Joo Sung
Jung, Hyun Chae
Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test
title Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test
title_full Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test
title_fullStr Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test
title_full_unstemmed Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test
title_short Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test
title_sort balloon expulsion test does not seem to be useful for screening or exclusion of dyssynergic defecation as a single test
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5503295/
https://www.ncbi.nlm.nih.gov/pubmed/28578564
http://dx.doi.org/10.5056/jnm16158
work_keys_str_mv AT leejooyoung balloonexpulsiontestdoesnotseemtobeusefulforscreeningorexclusionofdyssynergicdefecationasasingletest
AT hongkyoungsup balloonexpulsiontestdoesnotseemtobeusefulforscreeningorexclusionofdyssynergicdefecationasasingletest
AT kimjoosung balloonexpulsiontestdoesnotseemtobeusefulforscreeningorexclusionofdyssynergicdefecationasasingletest
AT junghyunchae balloonexpulsiontestdoesnotseemtobeusefulforscreeningorexclusionofdyssynergicdefecationasasingletest