Cargando…
Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test
BACKGROUND/AIMS: Balloon expulsion test (BET) is regarded as a screening tool of dyssynergic defecation (DD). However, some patients with normal BET results may be treated effectively by biofeedback training. This study aims to validate BET as a single screening test. METHODS: Two hundred and thirty...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Neurogastroenterology and Motility
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5503295/ https://www.ncbi.nlm.nih.gov/pubmed/28578564 http://dx.doi.org/10.5056/jnm16158 |
_version_ | 1783249074557812736 |
---|---|
author | Lee, Jooyoung Hong, Kyoung Sup Kim, Joo Sung Jung, Hyun Chae |
author_facet | Lee, Jooyoung Hong, Kyoung Sup Kim, Joo Sung Jung, Hyun Chae |
author_sort | Lee, Jooyoung |
collection | PubMed |
description | BACKGROUND/AIMS: Balloon expulsion test (BET) is regarded as a screening tool of dyssynergic defecation (DD). However, some patients with normal BET results may be treated effectively by biofeedback training. This study aims to validate BET as a single screening test. METHODS: Two hundred and thirty-two patients who were diagnosed with functional constipation or irritable bowel syndrome with constipation who underwent anorectal manometry (ARM) and BET at Seoul National University Hospital were enrolled. We evaluated the validity of BET based on ARM and electromyography (EMG) during biofeedback training. RESULTS: If BET ≤ 1 minute was defined as normal, sensitivity and negative predictive value (NPV) of BET in predicting paradoxical contraction based on ARM findings were 71.4% and 13.9%. If BET ≤ 3 minutes was defined as normal, sensitivity and NPV were 35.2% and 6.6%. Specificity and positive predictive value (PPV) of BET ≤ 3 minutes criteria were 84.8% and 93.3%. Same analysis was conducted in 107 patients who underwent EMG during biofeedback training. With 1-minute criteria, sensitivity and NPV of BET were 70.3% and 14.3%. With 3 minutes criteria, sensitivity and NPV of BET was 38.6% and 8.8%. Specificity and positive predictive values were both 100.0%. CONCLUSIONS: Based on either ARM or EMG during biofeedback training, sensitivity was at most 71.4% and NPV was less than 15.0% irrespective of whether BET was within 1minute or within 3 minutes. BET seems to have a limitation as both a screening test for dyssynergic defecation and a simple assessment to rule out the necessity of biofeedback training. |
format | Online Article Text |
id | pubmed-5503295 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Korean Society of Neurogastroenterology and Motility |
record_format | MEDLINE/PubMed |
spelling | pubmed-55032952017-07-12 Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test Lee, Jooyoung Hong, Kyoung Sup Kim, Joo Sung Jung, Hyun Chae J Neurogastroenterol Motil Original Article BACKGROUND/AIMS: Balloon expulsion test (BET) is regarded as a screening tool of dyssynergic defecation (DD). However, some patients with normal BET results may be treated effectively by biofeedback training. This study aims to validate BET as a single screening test. METHODS: Two hundred and thirty-two patients who were diagnosed with functional constipation or irritable bowel syndrome with constipation who underwent anorectal manometry (ARM) and BET at Seoul National University Hospital were enrolled. We evaluated the validity of BET based on ARM and electromyography (EMG) during biofeedback training. RESULTS: If BET ≤ 1 minute was defined as normal, sensitivity and negative predictive value (NPV) of BET in predicting paradoxical contraction based on ARM findings were 71.4% and 13.9%. If BET ≤ 3 minutes was defined as normal, sensitivity and NPV were 35.2% and 6.6%. Specificity and positive predictive value (PPV) of BET ≤ 3 minutes criteria were 84.8% and 93.3%. Same analysis was conducted in 107 patients who underwent EMG during biofeedback training. With 1-minute criteria, sensitivity and NPV of BET were 70.3% and 14.3%. With 3 minutes criteria, sensitivity and NPV of BET was 38.6% and 8.8%. Specificity and positive predictive values were both 100.0%. CONCLUSIONS: Based on either ARM or EMG during biofeedback training, sensitivity was at most 71.4% and NPV was less than 15.0% irrespective of whether BET was within 1minute or within 3 minutes. BET seems to have a limitation as both a screening test for dyssynergic defecation and a simple assessment to rule out the necessity of biofeedback training. Korean Society of Neurogastroenterology and Motility 2017-07 2017-07-01 /pmc/articles/PMC5503295/ /pubmed/28578564 http://dx.doi.org/10.5056/jnm16158 Text en © 2017 The Korean Society of Neurogastroenterology and Motility This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Jooyoung Hong, Kyoung Sup Kim, Joo Sung Jung, Hyun Chae Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test |
title | Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test |
title_full | Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test |
title_fullStr | Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test |
title_full_unstemmed | Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test |
title_short | Balloon Expulsion Test Does Not Seem to Be Useful for Screening or Exclusion of Dyssynergic Defecation as a Single Test |
title_sort | balloon expulsion test does not seem to be useful for screening or exclusion of dyssynergic defecation as a single test |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5503295/ https://www.ncbi.nlm.nih.gov/pubmed/28578564 http://dx.doi.org/10.5056/jnm16158 |
work_keys_str_mv | AT leejooyoung balloonexpulsiontestdoesnotseemtobeusefulforscreeningorexclusionofdyssynergicdefecationasasingletest AT hongkyoungsup balloonexpulsiontestdoesnotseemtobeusefulforscreeningorexclusionofdyssynergicdefecationasasingletest AT kimjoosung balloonexpulsiontestdoesnotseemtobeusefulforscreeningorexclusionofdyssynergicdefecationasasingletest AT junghyunchae balloonexpulsiontestdoesnotseemtobeusefulforscreeningorexclusionofdyssynergicdefecationasasingletest |