Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography

Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batche...

Descripción completa

Detalles Bibliográficos
Autores principales: Affatato, Saverio, Zanini, Filippo, Carmignato, Simone
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5503355/
https://www.ncbi.nlm.nih.gov/pubmed/28772616
http://dx.doi.org/10.3390/ma10030259
_version_ 1783249087909330944
author Affatato, Saverio
Zanini, Filippo
Carmignato, Simone
author_facet Affatato, Saverio
Zanini, Filippo
Carmignato, Simone
author_sort Affatato, Saverio
collection PubMed
description Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups’ surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations.
format Online
Article
Text
id pubmed-5503355
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-55033552017-07-28 Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography Affatato, Saverio Zanini, Filippo Carmignato, Simone Materials (Basel) Article Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups’ surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations. MDPI 2017-03-03 /pmc/articles/PMC5503355/ /pubmed/28772616 http://dx.doi.org/10.3390/ma10030259 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Affatato, Saverio
Zanini, Filippo
Carmignato, Simone
Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography
title Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography
title_full Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography
title_fullStr Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography
title_full_unstemmed Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography
title_short Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography
title_sort quantification of wear and deformation in different configurations of polyethylene acetabular cups using micro x-ray computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5503355/
https://www.ncbi.nlm.nih.gov/pubmed/28772616
http://dx.doi.org/10.3390/ma10030259
work_keys_str_mv AT affatatosaverio quantificationofwearanddeformationindifferentconfigurationsofpolyethyleneacetabularcupsusingmicroxraycomputedtomography
AT zaninifilippo quantificationofwearanddeformationindifferentconfigurationsofpolyethyleneacetabularcupsusingmicroxraycomputedtomography
AT carmignatosimone quantificationofwearanddeformationindifferentconfigurationsofpolyethyleneacetabularcupsusingmicroxraycomputedtomography