Cargando…
Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
BACKGROUND: There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically. METHODS: Ten specimens of femurs scanned by CT were input onto Mimics to rebuild 3D models; their *stl format datase...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5504632/ https://www.ncbi.nlm.nih.gov/pubmed/28693543 http://dx.doi.org/10.1186/s12891-017-1651-9 |
_version_ | 1783249314562179072 |
---|---|
author | Peng, Matthew Jian-Qiao Chen, Hai-Yan Hu, Yong Ju, XiangYang Bai, Bo |
author_facet | Peng, Matthew Jian-Qiao Chen, Hai-Yan Hu, Yong Ju, XiangYang Bai, Bo |
author_sort | Peng, Matthew Jian-Qiao |
collection | PubMed |
description | BACKGROUND: There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically. METHODS: Ten specimens of femurs scanned by CT were input onto Mimics to rebuild 3D models; their *stl format dataset were imported into Geomagic-Studio for simulative osteotomy; the generated *.igs dataset were interacted by UG to fit solid models; the prosthesis were obtained by the same way from patients, and bored by punching bears designed by Pro-E virtually; cements between femora and prosthesis were extracted by deleting prosthesis; in HyperMesh, all compartments were assembled onto four artificial joint style as: (a) cemented long-stem prosthesis; (b) porous long-stem prosthesis; (c) cemented short-stem prosthesis; (d) porous short-stem prosthesis. Then, these numerical models of Finite Element Analysis were exported to AnSys for numerical solution. RESULTS: Observed whatever from femur or prosthesis or combinational femora-prostheses, “Kruskal-Wallis” value p > 0.05 demonstrates that displacement of (d) ≈ (a) ≈ (b) ≈ (c) shows nothing different significantly by comparison with 600 N load. If stresses are tested upon prosthesis, (d) ≈ (a) ≈ (b) ≈ (c) is also displayed; if upon femora, (d) ≈ (a) ≈ (b) < (c) is suggested; if upon integral joint, (d) ≈ (a) < (b) < (c) is presented. CONCLUSIONS: Mechanically, these four sorts of artificial joint replacement are stabilized in quantity. Cemented short-stem prostheses present the biggest stress, while porous short-stem & cemented long-stem designs are equivalently better than porous long-stem prostheses and alternatives for femoral-head replacement. The preferred design of those two depends on clinical conditions. The cemented long-stem is favorable for inactive elders with osteoporosis, and porously punched cementless short-stem design is suitable for patients with osteoporosis, while the porously punched cementless short-stem is favorable for those with a cement allergy. Clinically, the strength of this study is to enable preoperative strategy to provide acute correction and decrease procedure time. |
format | Online Article Text |
id | pubmed-5504632 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-55046322017-07-12 Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty Peng, Matthew Jian-Qiao Chen, Hai-Yan Hu, Yong Ju, XiangYang Bai, Bo BMC Musculoskelet Disord Research Article BACKGROUND: There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically. METHODS: Ten specimens of femurs scanned by CT were input onto Mimics to rebuild 3D models; their *stl format dataset were imported into Geomagic-Studio for simulative osteotomy; the generated *.igs dataset were interacted by UG to fit solid models; the prosthesis were obtained by the same way from patients, and bored by punching bears designed by Pro-E virtually; cements between femora and prosthesis were extracted by deleting prosthesis; in HyperMesh, all compartments were assembled onto four artificial joint style as: (a) cemented long-stem prosthesis; (b) porous long-stem prosthesis; (c) cemented short-stem prosthesis; (d) porous short-stem prosthesis. Then, these numerical models of Finite Element Analysis were exported to AnSys for numerical solution. RESULTS: Observed whatever from femur or prosthesis or combinational femora-prostheses, “Kruskal-Wallis” value p > 0.05 demonstrates that displacement of (d) ≈ (a) ≈ (b) ≈ (c) shows nothing different significantly by comparison with 600 N load. If stresses are tested upon prosthesis, (d) ≈ (a) ≈ (b) ≈ (c) is also displayed; if upon femora, (d) ≈ (a) ≈ (b) < (c) is suggested; if upon integral joint, (d) ≈ (a) < (b) < (c) is presented. CONCLUSIONS: Mechanically, these four sorts of artificial joint replacement are stabilized in quantity. Cemented short-stem prostheses present the biggest stress, while porous short-stem & cemented long-stem designs are equivalently better than porous long-stem prostheses and alternatives for femoral-head replacement. The preferred design of those two depends on clinical conditions. The cemented long-stem is favorable for inactive elders with osteoporosis, and porously punched cementless short-stem design is suitable for patients with osteoporosis, while the porously punched cementless short-stem is favorable for those with a cement allergy. Clinically, the strength of this study is to enable preoperative strategy to provide acute correction and decrease procedure time. BioMed Central 2017-07-11 /pmc/articles/PMC5504632/ /pubmed/28693543 http://dx.doi.org/10.1186/s12891-017-1651-9 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Peng, Matthew Jian-Qiao Chen, Hai-Yan Hu, Yong Ju, XiangYang Bai, Bo Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty |
title | Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty |
title_full | Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty |
title_fullStr | Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty |
title_full_unstemmed | Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty |
title_short | Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty |
title_sort | finite element analysis of porously punched prosthetic short stem virtually designed for simulative uncemented hip arthroplasty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5504632/ https://www.ncbi.nlm.nih.gov/pubmed/28693543 http://dx.doi.org/10.1186/s12891-017-1651-9 |
work_keys_str_mv | AT pengmatthewjianqiao finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty AT chenhaiyan finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty AT huyong finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty AT juxiangyang finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty AT baibo finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty |