Cargando…

Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty

BACKGROUND: There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically. METHODS: Ten specimens of femurs scanned by CT were input onto Mimics to rebuild 3D models; their *stl format datase...

Descripción completa

Detalles Bibliográficos
Autores principales: Peng, Matthew Jian-Qiao, Chen, Hai-Yan, Hu, Yong, Ju, XiangYang, Bai, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5504632/
https://www.ncbi.nlm.nih.gov/pubmed/28693543
http://dx.doi.org/10.1186/s12891-017-1651-9
_version_ 1783249314562179072
author Peng, Matthew Jian-Qiao
Chen, Hai-Yan
Hu, Yong
Ju, XiangYang
Bai, Bo
author_facet Peng, Matthew Jian-Qiao
Chen, Hai-Yan
Hu, Yong
Ju, XiangYang
Bai, Bo
author_sort Peng, Matthew Jian-Qiao
collection PubMed
description BACKGROUND: There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically. METHODS: Ten specimens of femurs scanned by CT were input onto Mimics to rebuild 3D models; their *stl format dataset were imported into Geomagic-Studio for simulative osteotomy; the generated *.igs dataset were interacted by UG to fit solid models; the prosthesis were obtained by the same way from patients, and bored by punching bears designed by Pro-E virtually; cements between femora and prosthesis were extracted by deleting prosthesis; in HyperMesh, all compartments were assembled onto four artificial joint style as: (a) cemented long-stem prosthesis; (b) porous long-stem prosthesis; (c) cemented short-stem prosthesis; (d) porous short-stem prosthesis. Then, these numerical models of Finite Element Analysis were exported to AnSys for numerical solution. RESULTS: Observed whatever from femur or prosthesis or combinational femora-prostheses, “Kruskal-Wallis” value p > 0.05 demonstrates that displacement of (d) ≈ (a) ≈ (b) ≈ (c) shows nothing different significantly by comparison with 600 N load. If stresses are tested upon prosthesis, (d) ≈ (a) ≈ (b) ≈ (c) is also displayed; if upon femora, (d) ≈ (a) ≈ (b) < (c) is suggested; if upon integral joint, (d) ≈ (a) < (b) < (c) is presented. CONCLUSIONS: Mechanically, these four sorts of artificial joint replacement are stabilized in quantity. Cemented short-stem prostheses present the biggest stress, while porous short-stem & cemented long-stem designs are equivalently better than porous long-stem prostheses and alternatives for femoral-head replacement. The preferred design of those two depends on clinical conditions. The cemented long-stem is favorable for inactive elders with osteoporosis, and porously punched cementless short-stem design is suitable for patients with osteoporosis, while the porously punched cementless short-stem is favorable for those with a cement allergy. Clinically, the strength of this study is to enable preoperative strategy to provide acute correction and decrease procedure time.
format Online
Article
Text
id pubmed-5504632
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-55046322017-07-12 Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty Peng, Matthew Jian-Qiao Chen, Hai-Yan Hu, Yong Ju, XiangYang Bai, Bo BMC Musculoskelet Disord Research Article BACKGROUND: There is no universal hip implant suitably fills all femoral types, whether prostheses of porous short-stem suitable for Hip Arthroplasty is to be measured scientifically. METHODS: Ten specimens of femurs scanned by CT were input onto Mimics to rebuild 3D models; their *stl format dataset were imported into Geomagic-Studio for simulative osteotomy; the generated *.igs dataset were interacted by UG to fit solid models; the prosthesis were obtained by the same way from patients, and bored by punching bears designed by Pro-E virtually; cements between femora and prosthesis were extracted by deleting prosthesis; in HyperMesh, all compartments were assembled onto four artificial joint style as: (a) cemented long-stem prosthesis; (b) porous long-stem prosthesis; (c) cemented short-stem prosthesis; (d) porous short-stem prosthesis. Then, these numerical models of Finite Element Analysis were exported to AnSys for numerical solution. RESULTS: Observed whatever from femur or prosthesis or combinational femora-prostheses, “Kruskal-Wallis” value p > 0.05 demonstrates that displacement of (d) ≈ (a) ≈ (b) ≈ (c) shows nothing different significantly by comparison with 600 N load. If stresses are tested upon prosthesis, (d) ≈ (a) ≈ (b) ≈ (c) is also displayed; if upon femora, (d) ≈ (a) ≈ (b) < (c) is suggested; if upon integral joint, (d) ≈ (a) < (b) < (c) is presented. CONCLUSIONS: Mechanically, these four sorts of artificial joint replacement are stabilized in quantity. Cemented short-stem prostheses present the biggest stress, while porous short-stem & cemented long-stem designs are equivalently better than porous long-stem prostheses and alternatives for femoral-head replacement. The preferred design of those two depends on clinical conditions. The cemented long-stem is favorable for inactive elders with osteoporosis, and porously punched cementless short-stem design is suitable for patients with osteoporosis, while the porously punched cementless short-stem is favorable for those with a cement allergy. Clinically, the strength of this study is to enable preoperative strategy to provide acute correction and decrease procedure time. BioMed Central 2017-07-11 /pmc/articles/PMC5504632/ /pubmed/28693543 http://dx.doi.org/10.1186/s12891-017-1651-9 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Peng, Matthew Jian-Qiao
Chen, Hai-Yan
Hu, Yong
Ju, XiangYang
Bai, Bo
Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
title Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
title_full Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
title_fullStr Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
title_full_unstemmed Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
title_short Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
title_sort finite element analysis of porously punched prosthetic short stem virtually designed for simulative uncemented hip arthroplasty
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5504632/
https://www.ncbi.nlm.nih.gov/pubmed/28693543
http://dx.doi.org/10.1186/s12891-017-1651-9
work_keys_str_mv AT pengmatthewjianqiao finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty
AT chenhaiyan finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty
AT huyong finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty
AT juxiangyang finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty
AT baibo finiteelementanalysisofporouslypunchedprostheticshortstemvirtuallydesignedforsimulativeuncementedhiparthroplasty