Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature

BACKGROUND: Airway obstruction or tracheoesophageal fistula (TEF) near the tracheal carina requires placement of Y-shaped stents. Herein, we describe our multicenter experience with the placement of Dumon silicone Y-stents. We also conduct a systematic review for studies describing the deployment of...

Descripción completa

Detalles Bibliográficos
Autores principales: Sehgal, Inderpaul Singh, Dhooria, Sahajal, Madan, Karan, Pattabhiraman, Vallandramam, Mehta, Ravindra, Goyal, Rajiv, Akkaraju, Jayachandra, Agarwal, Ritesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5504886/
https://www.ncbi.nlm.nih.gov/pubmed/28671160
http://dx.doi.org/10.4103/0970-2113.209241
_version_ 1783249370127269888
author Sehgal, Inderpaul Singh
Dhooria, Sahajal
Madan, Karan
Pattabhiraman, Vallandramam
Mehta, Ravindra
Goyal, Rajiv
Akkaraju, Jayachandra
Agarwal, Ritesh
author_facet Sehgal, Inderpaul Singh
Dhooria, Sahajal
Madan, Karan
Pattabhiraman, Vallandramam
Mehta, Ravindra
Goyal, Rajiv
Akkaraju, Jayachandra
Agarwal, Ritesh
author_sort Sehgal, Inderpaul Singh
collection PubMed
description BACKGROUND: Airway obstruction or tracheoesophageal fistula (TEF) near the tracheal carina requires placement of Y-shaped stents. Herein, we describe our multicenter experience with the placement of Dumon silicone Y-stents. We also conduct a systematic review for studies describing the deployment of airway silicone Y-stents. METHODS: This was a retrospective analysis of consecutive subjects who underwent placement of silicone Y-stents. The clinical details including the underlying diagnosis, indication for the placement of silicone Y-stents, success of stent placement, and follow-up are presented. The PubMed and EMBASE databases were also reviewed for studies describing the placement of silicone Y-stents. RESULTS: During the study, 27 silicone Y-stents were placed. The mean (standard deviation) age of the study population (85.2% males) was 57.7 (13.5) years. The stents were placed for airway obstruction in 77.8% and TEF in 29.6% of the patients. The most common underlying disease was carcinoma of the esophagus. The degree of airway obstruction was grade 3–4 in 18 subjects, and respiratory failure was encountered in 18 subjects. The stent was deployed successfully in all the subjects. No deaths were encountered during stent placement. Most subjects had rapid relief of symptoms following the procedure. Excessive secretions and mucostasis were the most common stent-related complications followed by the development of granulation tissue. The systematic review yielded nine studies (338 subjects with airway obstruction and/or TEF). The most common indication for silicone Y-stent placement was tracheobronchial obstruction and TEF due to malignancy. Benign disorders that necessitated stent placement included postintubation tracheal stenosis, airway malacia, and others. The stent was successfully placed in 98% with only one periprocedural death. Granulation tissue formation and mucostasis were the most common stent-related complications. CONCLUSION: Placement of silicone Y-stent is a safe and effective procedure that provides quick relief of symptoms in subjects presenting with airway obstruction and TEF at or near the tracheal carina.
format Online
Article
Text
id pubmed-5504886
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-55048862017-07-12 Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature Sehgal, Inderpaul Singh Dhooria, Sahajal Madan, Karan Pattabhiraman, Vallandramam Mehta, Ravindra Goyal, Rajiv Akkaraju, Jayachandra Agarwal, Ritesh Lung India Original Article BACKGROUND: Airway obstruction or tracheoesophageal fistula (TEF) near the tracheal carina requires placement of Y-shaped stents. Herein, we describe our multicenter experience with the placement of Dumon silicone Y-stents. We also conduct a systematic review for studies describing the deployment of airway silicone Y-stents. METHODS: This was a retrospective analysis of consecutive subjects who underwent placement of silicone Y-stents. The clinical details including the underlying diagnosis, indication for the placement of silicone Y-stents, success of stent placement, and follow-up are presented. The PubMed and EMBASE databases were also reviewed for studies describing the placement of silicone Y-stents. RESULTS: During the study, 27 silicone Y-stents were placed. The mean (standard deviation) age of the study population (85.2% males) was 57.7 (13.5) years. The stents were placed for airway obstruction in 77.8% and TEF in 29.6% of the patients. The most common underlying disease was carcinoma of the esophagus. The degree of airway obstruction was grade 3–4 in 18 subjects, and respiratory failure was encountered in 18 subjects. The stent was deployed successfully in all the subjects. No deaths were encountered during stent placement. Most subjects had rapid relief of symptoms following the procedure. Excessive secretions and mucostasis were the most common stent-related complications followed by the development of granulation tissue. The systematic review yielded nine studies (338 subjects with airway obstruction and/or TEF). The most common indication for silicone Y-stent placement was tracheobronchial obstruction and TEF due to malignancy. Benign disorders that necessitated stent placement included postintubation tracheal stenosis, airway malacia, and others. The stent was successfully placed in 98% with only one periprocedural death. Granulation tissue formation and mucostasis were the most common stent-related complications. CONCLUSION: Placement of silicone Y-stent is a safe and effective procedure that provides quick relief of symptoms in subjects presenting with airway obstruction and TEF at or near the tracheal carina. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5504886/ /pubmed/28671160 http://dx.doi.org/10.4103/0970-2113.209241 Text en Copyright: © 2017 Indian Chest Society http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sehgal, Inderpaul Singh
Dhooria, Sahajal
Madan, Karan
Pattabhiraman, Vallandramam
Mehta, Ravindra
Goyal, Rajiv
Akkaraju, Jayachandra
Agarwal, Ritesh
Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature
title Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature
title_full Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature
title_fullStr Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature
title_full_unstemmed Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature
title_short Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature
title_sort placement of tracheobronchial silicone y-stents: multicenter experience and systematic review of the literature
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5504886/
https://www.ncbi.nlm.nih.gov/pubmed/28671160
http://dx.doi.org/10.4103/0970-2113.209241
work_keys_str_mv AT sehgalinderpaulsingh placementoftracheobronchialsiliconeystentsmulticenterexperienceandsystematicreviewoftheliterature
AT dhooriasahajal placementoftracheobronchialsiliconeystentsmulticenterexperienceandsystematicreviewoftheliterature
AT madankaran placementoftracheobronchialsiliconeystentsmulticenterexperienceandsystematicreviewoftheliterature
AT pattabhiramanvallandramam placementoftracheobronchialsiliconeystentsmulticenterexperienceandsystematicreviewoftheliterature
AT mehtaravindra placementoftracheobronchialsiliconeystentsmulticenterexperienceandsystematicreviewoftheliterature
AT goyalrajiv placementoftracheobronchialsiliconeystentsmulticenterexperienceandsystematicreviewoftheliterature
AT akkarajujayachandra placementoftracheobronchialsiliconeystentsmulticenterexperienceandsystematicreviewoftheliterature
AT agarwalritesh placementoftracheobronchialsiliconeystentsmulticenterexperienceandsystematicreviewoftheliterature