Cargando…

Whole-Body Low-Dose Computed Tomography (WBLDCT) in Assessment of Patients with Multiple Myeloma – Pilot Study and Standard Imaging Protocol Suggestion

BACKGROUND: For decades, the main imaging tool in multiple myeloma (MM) patients was plain radiography. However, computed tomography (CT) has been included in the updated criteria of MM. The main disadvantage of CT is a considerably high radiation dose. Therefore, low-dose CT protocols could be a so...

Descripción completa

Detalles Bibliográficos
Autores principales: Chrzan, Robert, Jurczyszyn, Artur, Urbanik, Andrzej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5505575/
https://www.ncbi.nlm.nih.gov/pubmed/28740565
http://dx.doi.org/10.12659/PJR.901742
_version_ 1783249453171343360
author Chrzan, Robert
Jurczyszyn, Artur
Urbanik, Andrzej
author_facet Chrzan, Robert
Jurczyszyn, Artur
Urbanik, Andrzej
author_sort Chrzan, Robert
collection PubMed
description BACKGROUND: For decades, the main imaging tool in multiple myeloma (MM) patients was plain radiography. However, computed tomography (CT) has been included in the updated criteria of MM. The main disadvantage of CT is a considerably high radiation dose. Therefore, low-dose CT protocols could be a solution. The aim of the study was to (1) preliminarily analyse the usefulness of Whole-Body Low-Dose CT (WBLDCT) in the evaluation of patients with MM and (2) to make adjustments in the standard CT imaging protocol. MATERIAL/METHODS: In 41 patients with MM, WBLDCT was performed. The following parameters were used: detector configuration – 80×0.5 mm, scanning range in a single spiral acquisition from the skull to the proximal femoral bones, tube voltage – 120 kVp, current tube time product – 86 mAs, slice thickness 1 mm. Two sets of axial images were reconstructed for bone and soft tissue assessment, respectively. Secondary coronal and sagittal reconstructions were generated. Typical MM features were analysed and qualitatively compared with radiography results. RESULTS: A potentially increased sensitivity of CT, as compared to radiography, in detecting lytic foci obscured by other structures or with a small degree of destruction was seen. A potentially increased specificity of CT was found in detecting cases of small foci suspicious of lytic lesions on skull radiographs, seen as arachnoid granulations fovea in CT. The following radiation parameters were recorded: max. CTDIvol – 7.4 mGy and DLP – 660–810 mGy×cm. WBLDCT was much shorter and more convenient to patients. CONCLUSIONS: WBLDCT may become a valuable part of the assessment of MM features at a much lower radiation dose compared to standard CT protocols. It has a potential ability to increase diagnostic accuracy compared to radiography.
format Online
Article
Text
id pubmed-5505575
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-55055752017-07-24 Whole-Body Low-Dose Computed Tomography (WBLDCT) in Assessment of Patients with Multiple Myeloma – Pilot Study and Standard Imaging Protocol Suggestion Chrzan, Robert Jurczyszyn, Artur Urbanik, Andrzej Pol J Radiol Original Article BACKGROUND: For decades, the main imaging tool in multiple myeloma (MM) patients was plain radiography. However, computed tomography (CT) has been included in the updated criteria of MM. The main disadvantage of CT is a considerably high radiation dose. Therefore, low-dose CT protocols could be a solution. The aim of the study was to (1) preliminarily analyse the usefulness of Whole-Body Low-Dose CT (WBLDCT) in the evaluation of patients with MM and (2) to make adjustments in the standard CT imaging protocol. MATERIAL/METHODS: In 41 patients with MM, WBLDCT was performed. The following parameters were used: detector configuration – 80×0.5 mm, scanning range in a single spiral acquisition from the skull to the proximal femoral bones, tube voltage – 120 kVp, current tube time product – 86 mAs, slice thickness 1 mm. Two sets of axial images were reconstructed for bone and soft tissue assessment, respectively. Secondary coronal and sagittal reconstructions were generated. Typical MM features were analysed and qualitatively compared with radiography results. RESULTS: A potentially increased sensitivity of CT, as compared to radiography, in detecting lytic foci obscured by other structures or with a small degree of destruction was seen. A potentially increased specificity of CT was found in detecting cases of small foci suspicious of lytic lesions on skull radiographs, seen as arachnoid granulations fovea in CT. The following radiation parameters were recorded: max. CTDIvol – 7.4 mGy and DLP – 660–810 mGy×cm. WBLDCT was much shorter and more convenient to patients. CONCLUSIONS: WBLDCT may become a valuable part of the assessment of MM features at a much lower radiation dose compared to standard CT protocols. It has a potential ability to increase diagnostic accuracy compared to radiography. International Scientific Literature, Inc. 2017-07-01 /pmc/articles/PMC5505575/ /pubmed/28740565 http://dx.doi.org/10.12659/PJR.901742 Text en © Pol J Radiol, 2017 This is an open access article. Unrestricted non-commercial use is permitted provided the original work is properly cited.
spellingShingle Original Article
Chrzan, Robert
Jurczyszyn, Artur
Urbanik, Andrzej
Whole-Body Low-Dose Computed Tomography (WBLDCT) in Assessment of Patients with Multiple Myeloma – Pilot Study and Standard Imaging Protocol Suggestion
title Whole-Body Low-Dose Computed Tomography (WBLDCT) in Assessment of Patients with Multiple Myeloma – Pilot Study and Standard Imaging Protocol Suggestion
title_full Whole-Body Low-Dose Computed Tomography (WBLDCT) in Assessment of Patients with Multiple Myeloma – Pilot Study and Standard Imaging Protocol Suggestion
title_fullStr Whole-Body Low-Dose Computed Tomography (WBLDCT) in Assessment of Patients with Multiple Myeloma – Pilot Study and Standard Imaging Protocol Suggestion
title_full_unstemmed Whole-Body Low-Dose Computed Tomography (WBLDCT) in Assessment of Patients with Multiple Myeloma – Pilot Study and Standard Imaging Protocol Suggestion
title_short Whole-Body Low-Dose Computed Tomography (WBLDCT) in Assessment of Patients with Multiple Myeloma – Pilot Study and Standard Imaging Protocol Suggestion
title_sort whole-body low-dose computed tomography (wbldct) in assessment of patients with multiple myeloma – pilot study and standard imaging protocol suggestion
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5505575/
https://www.ncbi.nlm.nih.gov/pubmed/28740565
http://dx.doi.org/10.12659/PJR.901742
work_keys_str_mv AT chrzanrobert wholebodylowdosecomputedtomographywbldctinassessmentofpatientswithmultiplemyelomapilotstudyandstandardimagingprotocolsuggestion
AT jurczyszynartur wholebodylowdosecomputedtomographywbldctinassessmentofpatientswithmultiplemyelomapilotstudyandstandardimagingprotocolsuggestion
AT urbanikandrzej wholebodylowdosecomputedtomographywbldctinassessmentofpatientswithmultiplemyelomapilotstudyandstandardimagingprotocolsuggestion