Cargando…
The larynx ruler to measure height and profile of vocal folds: a proof of concept
INTRODUCTION: Glottic leakage during phonation is a direct consequence of unilateral vocal fold (VF) paralysis. This air leakage can be in the horizontal plane and in the vertical plane. Presently, there is no easily applicable medical device allowing noninvasive, office-based measurement of the rel...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5505612/ https://www.ncbi.nlm.nih.gov/pubmed/28740437 http://dx.doi.org/10.2147/MDER.S136561 |
_version_ | 1783249455599845376 |
---|---|
author | Desuter, Gauthier Mertens, Benjamin Delchambre, Alain van Lith-Bijl, Julie van Benthem, Peter Paul Sjögren, Elisabeth |
author_facet | Desuter, Gauthier Mertens, Benjamin Delchambre, Alain van Lith-Bijl, Julie van Benthem, Peter Paul Sjögren, Elisabeth |
author_sort | Desuter, Gauthier |
collection | PubMed |
description | INTRODUCTION: Glottic leakage during phonation is a direct consequence of unilateral vocal fold (VF) paralysis. This air leakage can be in the horizontal plane and in the vertical plane. Presently, there is no easily applicable medical device allowing noninvasive, office-based measurement of the relative vertical position of the VFs. The larynx ruler (LR) is a laser-based measuring device that could meet the previously stated need, using a flexible endoscope. This study represents a proof of concept regarding the use of the LR in assessing VF relative positions in the vertical plane. MATERIALS AND METHODS: One fresh male human cadaver larynx, free of neurologic and anatomic disease, was explored with the LR system through the operative channel of a flexible gastroenterology video-endoscope. The tip of the video-endoscope was located in the laryngeal vestibule. The right crico-arytenoid joint was posteriorly disarticulated. Tilting of the VF was obtained by pulling or pushing the arytenoid cartilage with a mosquito forceps fixed to the stump of the previously sectioned superior tip of the posterior crico-arytenoid muscle allowing anterior and posterior tilting of the arytenoid cartilage in order to induce an elevation or a depression of the VF process. Ten “push” and ten “pull” sessions were performed. The distance from the tip of the video-endoscope to each illuminated pixel of the laser beam was recorded. The level difference between the left and right VFs was measured for each recording. RESULTS: Data provided by the LR were consistently in accordance with the movements applied on the VFs. The accuracy of 0.2 mm of the LR is compatible with the envisioned applications for the human larynx. CONCLUSION: The LR system represents a feasible technique to evaluate respective vertical position of VFs in the human larynx. Technical limitations were identified that will require improvements before experimental use on human beings. |
format | Online Article Text |
id | pubmed-5505612 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-55056122017-07-24 The larynx ruler to measure height and profile of vocal folds: a proof of concept Desuter, Gauthier Mertens, Benjamin Delchambre, Alain van Lith-Bijl, Julie van Benthem, Peter Paul Sjögren, Elisabeth Med Devices (Auckl) Original Research INTRODUCTION: Glottic leakage during phonation is a direct consequence of unilateral vocal fold (VF) paralysis. This air leakage can be in the horizontal plane and in the vertical plane. Presently, there is no easily applicable medical device allowing noninvasive, office-based measurement of the relative vertical position of the VFs. The larynx ruler (LR) is a laser-based measuring device that could meet the previously stated need, using a flexible endoscope. This study represents a proof of concept regarding the use of the LR in assessing VF relative positions in the vertical plane. MATERIALS AND METHODS: One fresh male human cadaver larynx, free of neurologic and anatomic disease, was explored with the LR system through the operative channel of a flexible gastroenterology video-endoscope. The tip of the video-endoscope was located in the laryngeal vestibule. The right crico-arytenoid joint was posteriorly disarticulated. Tilting of the VF was obtained by pulling or pushing the arytenoid cartilage with a mosquito forceps fixed to the stump of the previously sectioned superior tip of the posterior crico-arytenoid muscle allowing anterior and posterior tilting of the arytenoid cartilage in order to induce an elevation or a depression of the VF process. Ten “push” and ten “pull” sessions were performed. The distance from the tip of the video-endoscope to each illuminated pixel of the laser beam was recorded. The level difference between the left and right VFs was measured for each recording. RESULTS: Data provided by the LR were consistently in accordance with the movements applied on the VFs. The accuracy of 0.2 mm of the LR is compatible with the envisioned applications for the human larynx. CONCLUSION: The LR system represents a feasible technique to evaluate respective vertical position of VFs in the human larynx. Technical limitations were identified that will require improvements before experimental use on human beings. Dove Medical Press 2017-07-05 /pmc/articles/PMC5505612/ /pubmed/28740437 http://dx.doi.org/10.2147/MDER.S136561 Text en © 2017 Desuter et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Desuter, Gauthier Mertens, Benjamin Delchambre, Alain van Lith-Bijl, Julie van Benthem, Peter Paul Sjögren, Elisabeth The larynx ruler to measure height and profile of vocal folds: a proof of concept |
title | The larynx ruler to measure height and profile of vocal folds: a proof of concept |
title_full | The larynx ruler to measure height and profile of vocal folds: a proof of concept |
title_fullStr | The larynx ruler to measure height and profile of vocal folds: a proof of concept |
title_full_unstemmed | The larynx ruler to measure height and profile of vocal folds: a proof of concept |
title_short | The larynx ruler to measure height and profile of vocal folds: a proof of concept |
title_sort | larynx ruler to measure height and profile of vocal folds: a proof of concept |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5505612/ https://www.ncbi.nlm.nih.gov/pubmed/28740437 http://dx.doi.org/10.2147/MDER.S136561 |
work_keys_str_mv | AT desutergauthier thelarynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT mertensbenjamin thelarynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT delchambrealain thelarynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT vanlithbijljulie thelarynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT vanbenthempeterpaul thelarynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT sjogrenelisabeth thelarynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT desutergauthier larynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT mertensbenjamin larynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT delchambrealain larynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT vanlithbijljulie larynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT vanbenthempeterpaul larynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept AT sjogrenelisabeth larynxrulertomeasureheightandprofileofvocalfoldsaproofofconcept |