Cargando…

Lengthening of the humerus with intramedullary lengthening nails—preliminary report

Distraction osteogenesis of the humerus with fully implantable lengthening is now possible since the diameter of the available nails was reduced to 10 mm and below. We report on the first intramedullary lengthening cases of the humerus with two different lengthening devices (FITBONE and PRECICE). Tw...

Descripción completa

Detalles Bibliográficos
Autores principales: Fürmetz, Julian, Kold, Søren, Schuster, Nikola, Wolf, Florian, Thaller, Peter H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Milan 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5505882/
https://www.ncbi.nlm.nih.gov/pubmed/28439819
http://dx.doi.org/10.1007/s11751-017-0286-6
_version_ 1783249478199803904
author Fürmetz, Julian
Kold, Søren
Schuster, Nikola
Wolf, Florian
Thaller, Peter H.
author_facet Fürmetz, Julian
Kold, Søren
Schuster, Nikola
Wolf, Florian
Thaller, Peter H.
author_sort Fürmetz, Julian
collection PubMed
description Distraction osteogenesis of the humerus with fully implantable lengthening is now possible since the diameter of the available nails was reduced to 10 mm and below. We report on the first intramedullary lengthening cases of the humerus with two different lengthening devices (FITBONE and PRECICE). Two different approaches and implantation techniques were used. We retrospectively reviewed clinical and radiographic data and pointed out results, pitfalls and complications of the procedure. Four adult patients with relevant length discrepancy of the humerus were treated with fully implantable systems in two centers between 2012 and 2015. Three patients were treated with FITBONE by an antegrade approach; one patient had lengthening with a PRECICE and a retrograde approach. Average nail lengthening was 55 mm (40–65 mm), and the average duration of lengthening was 70 days (52–95 days). The average distraction index was 0.72 mm/day (range 0.4–1.0 mm/day) or 12.5 days/cm (range 8.0–16.2 days/cm). The average consolidation index was 33.6 days/cm (range 25–45 days/cm). There was an implant failure (arrest) with the PRECICE. After consolidation and exchange with a technically improved implant, the course of treatment was uneventful. In patients with antegrade lengthening shoulder abduction decreased, and in the patient with the retrograde approach it improved but elbow extension decreased marginally. Reduced motion of the adjacent joints can be a major problem in intramedullary lengthening of the humerus. This first case series in the field of a rare indication suggests that lengthening of the humerus by fully implantable lengthening nails might be a valuable alternative to lengthening with external fixation. Main advantage of the PRECICE technology is the possible shortening in-between of lengthening.
format Online
Article
Text
id pubmed-5505882
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Milan
record_format MEDLINE/PubMed
spelling pubmed-55058822017-07-25 Lengthening of the humerus with intramedullary lengthening nails—preliminary report Fürmetz, Julian Kold, Søren Schuster, Nikola Wolf, Florian Thaller, Peter H. Strategies Trauma Limb Reconstr Original Article Distraction osteogenesis of the humerus with fully implantable lengthening is now possible since the diameter of the available nails was reduced to 10 mm and below. We report on the first intramedullary lengthening cases of the humerus with two different lengthening devices (FITBONE and PRECICE). Two different approaches and implantation techniques were used. We retrospectively reviewed clinical and radiographic data and pointed out results, pitfalls and complications of the procedure. Four adult patients with relevant length discrepancy of the humerus were treated with fully implantable systems in two centers between 2012 and 2015. Three patients were treated with FITBONE by an antegrade approach; one patient had lengthening with a PRECICE and a retrograde approach. Average nail lengthening was 55 mm (40–65 mm), and the average duration of lengthening was 70 days (52–95 days). The average distraction index was 0.72 mm/day (range 0.4–1.0 mm/day) or 12.5 days/cm (range 8.0–16.2 days/cm). The average consolidation index was 33.6 days/cm (range 25–45 days/cm). There was an implant failure (arrest) with the PRECICE. After consolidation and exchange with a technically improved implant, the course of treatment was uneventful. In patients with antegrade lengthening shoulder abduction decreased, and in the patient with the retrograde approach it improved but elbow extension decreased marginally. Reduced motion of the adjacent joints can be a major problem in intramedullary lengthening of the humerus. This first case series in the field of a rare indication suggests that lengthening of the humerus by fully implantable lengthening nails might be a valuable alternative to lengthening with external fixation. Main advantage of the PRECICE technology is the possible shortening in-between of lengthening. Springer Milan 2017-04-24 2017-08 /pmc/articles/PMC5505882/ /pubmed/28439819 http://dx.doi.org/10.1007/s11751-017-0286-6 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Fürmetz, Julian
Kold, Søren
Schuster, Nikola
Wolf, Florian
Thaller, Peter H.
Lengthening of the humerus with intramedullary lengthening nails—preliminary report
title Lengthening of the humerus with intramedullary lengthening nails—preliminary report
title_full Lengthening of the humerus with intramedullary lengthening nails—preliminary report
title_fullStr Lengthening of the humerus with intramedullary lengthening nails—preliminary report
title_full_unstemmed Lengthening of the humerus with intramedullary lengthening nails—preliminary report
title_short Lengthening of the humerus with intramedullary lengthening nails—preliminary report
title_sort lengthening of the humerus with intramedullary lengthening nails—preliminary report
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5505882/
https://www.ncbi.nlm.nih.gov/pubmed/28439819
http://dx.doi.org/10.1007/s11751-017-0286-6
work_keys_str_mv AT furmetzjulian lengtheningofthehumeruswithintramedullarylengtheningnailspreliminaryreport
AT koldsøren lengtheningofthehumeruswithintramedullarylengtheningnailspreliminaryreport
AT schusternikola lengtheningofthehumeruswithintramedullarylengtheningnailspreliminaryreport
AT wolfflorian lengtheningofthehumeruswithintramedullarylengtheningnailspreliminaryreport
AT thallerpeterh lengtheningofthehumeruswithintramedullarylengtheningnailspreliminaryreport