Cargando…

The Effect of Surfactant Content over Cu-Ni Coatings Electroplated by the sc-CO(2) Technique

Co-plating of Cu-Ni coatings by supercritical CO(2) (sc-CO(2)) and conventional electroplating processes was studied in this work. 1,4-butynediol was chosen as the surfactant and the effects of adjusting the surfactant content were described. Although the sc-CO(2) process displayed lower current eff...

Descripción completa

Detalles Bibliográficos
Autores principales: Chuang, Ho-Chiao, Sánchez, Jorge, Cheng, Hsiang-Yun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5506913/
https://www.ncbi.nlm.nih.gov/pubmed/28772787
http://dx.doi.org/10.3390/ma10040428
_version_ 1783249648441360384
author Chuang, Ho-Chiao
Sánchez, Jorge
Cheng, Hsiang-Yun
author_facet Chuang, Ho-Chiao
Sánchez, Jorge
Cheng, Hsiang-Yun
author_sort Chuang, Ho-Chiao
collection PubMed
description Co-plating of Cu-Ni coatings by supercritical CO(2) (sc-CO(2)) and conventional electroplating processes was studied in this work. 1,4-butynediol was chosen as the surfactant and the effects of adjusting the surfactant content were described. Although the sc-CO(2) process displayed lower current efficiency, it effectively removed excess hydrogen that causes defects on the coating surface, refined grain size, reduced surface roughness, and increased electrochemical resistance. Surface roughness of coatings fabricated by the sc-CO(2) process was reduced by an average of 10%, and a maximum of 55%, compared to conventional process at different fabrication parameters. Cu-Ni coatings produced by the sc-CO(2) process displayed increased corrosion potential of ~0.05 V over Cu-Ni coatings produced by the conventional process, and 0.175 V over pure Cu coatings produced by the conventional process. For coatings ~10 µm thick, internal stress developed from the sc-CO(2) process were ~20 MPa lower than conventional process. Finally, the preferred crystal orientation of the fabricated coatings remained in the (111) direction regardless of the process used or surfactant content.
format Online
Article
Text
id pubmed-5506913
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-55069132017-07-28 The Effect of Surfactant Content over Cu-Ni Coatings Electroplated by the sc-CO(2) Technique Chuang, Ho-Chiao Sánchez, Jorge Cheng, Hsiang-Yun Materials (Basel) Article Co-plating of Cu-Ni coatings by supercritical CO(2) (sc-CO(2)) and conventional electroplating processes was studied in this work. 1,4-butynediol was chosen as the surfactant and the effects of adjusting the surfactant content were described. Although the sc-CO(2) process displayed lower current efficiency, it effectively removed excess hydrogen that causes defects on the coating surface, refined grain size, reduced surface roughness, and increased electrochemical resistance. Surface roughness of coatings fabricated by the sc-CO(2) process was reduced by an average of 10%, and a maximum of 55%, compared to conventional process at different fabrication parameters. Cu-Ni coatings produced by the sc-CO(2) process displayed increased corrosion potential of ~0.05 V over Cu-Ni coatings produced by the conventional process, and 0.175 V over pure Cu coatings produced by the conventional process. For coatings ~10 µm thick, internal stress developed from the sc-CO(2) process were ~20 MPa lower than conventional process. Finally, the preferred crystal orientation of the fabricated coatings remained in the (111) direction regardless of the process used or surfactant content. MDPI 2017-04-19 /pmc/articles/PMC5506913/ /pubmed/28772787 http://dx.doi.org/10.3390/ma10040428 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chuang, Ho-Chiao
Sánchez, Jorge
Cheng, Hsiang-Yun
The Effect of Surfactant Content over Cu-Ni Coatings Electroplated by the sc-CO(2) Technique
title The Effect of Surfactant Content over Cu-Ni Coatings Electroplated by the sc-CO(2) Technique
title_full The Effect of Surfactant Content over Cu-Ni Coatings Electroplated by the sc-CO(2) Technique
title_fullStr The Effect of Surfactant Content over Cu-Ni Coatings Electroplated by the sc-CO(2) Technique
title_full_unstemmed The Effect of Surfactant Content over Cu-Ni Coatings Electroplated by the sc-CO(2) Technique
title_short The Effect of Surfactant Content over Cu-Ni Coatings Electroplated by the sc-CO(2) Technique
title_sort effect of surfactant content over cu-ni coatings electroplated by the sc-co(2) technique
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5506913/
https://www.ncbi.nlm.nih.gov/pubmed/28772787
http://dx.doi.org/10.3390/ma10040428
work_keys_str_mv AT chuanghochiao theeffectofsurfactantcontentovercunicoatingselectroplatedbythescco2technique
AT sanchezjorge theeffectofsurfactantcontentovercunicoatingselectroplatedbythescco2technique
AT chenghsiangyun theeffectofsurfactantcontentovercunicoatingselectroplatedbythescco2technique
AT chuanghochiao effectofsurfactantcontentovercunicoatingselectroplatedbythescco2technique
AT sanchezjorge effectofsurfactantcontentovercunicoatingselectroplatedbythescco2technique
AT chenghsiangyun effectofsurfactantcontentovercunicoatingselectroplatedbythescco2technique