Cargando…

The Reliability of Panoramic Radiography Versus Cone Beam Computed Tomography when Evaluating the Distance to the Alveolar Nerve in the Site of Lateral Teeth

BACKGROUND: The aim of this study was to compare the reliability of panoramic radiography (PR) and cone beam computed tomography (CBCT) in the evaluation of the distance of the roots of lateral teeth to the inferior alveolar nerve canal (IANC). MATERIAL/METHODS: 100 PR and 100 CBCT images that met t...

Descripción completa

Detalles Bibliográficos
Autores principales: Česaitienė, Gabrielė, Česaitis, Kęstutis, Junevičius, Jonas, Venskutonis, Tadas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5507794/
https://www.ncbi.nlm.nih.gov/pubmed/28674379
http://dx.doi.org/10.12659/MSM.902083
_version_ 1783249780946763776
author Česaitienė, Gabrielė
Česaitis, Kęstutis
Junevičius, Jonas
Venskutonis, Tadas
author_facet Česaitienė, Gabrielė
Česaitis, Kęstutis
Junevičius, Jonas
Venskutonis, Tadas
author_sort Česaitienė, Gabrielė
collection PubMed
description BACKGROUND: The aim of this study was to compare the reliability of panoramic radiography (PR) and cone beam computed tomography (CBCT) in the evaluation of the distance of the roots of lateral teeth to the inferior alveolar nerve canal (IANC). MATERIAL/METHODS: 100 PR and 100 CBCT images that met the selection criteria were selected from the database. In PR images, the distances were measured using an electronic caliper with 0.01 mm accuracy and white light x-ray film reviewer. Actual values of the measurements were calculated taking into consideration the magnification used in PR images (130%). Measurements on CBCT images were performed using i-CAT Vision software. Statistical data analysis was performed using R software and applying Welch’s t-test and the Wilcoxon test. RESULTS: There was no statistically significant difference in the mean distance from the root of the second premolar and the mesial and distal roots of the first molar to the IANC between PR and CBCT images. The difference in the mean distance from the mesial and distal roots of the second and the third molars to the IANC measured in PR and CBCT images was statistically significant. CONCLUSIONS: PR may be uninformative or misleading when measuring the distance from the mesial and distal roots of the second and the third molars to the IANC.
format Online
Article
Text
id pubmed-5507794
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-55077942017-07-26 The Reliability of Panoramic Radiography Versus Cone Beam Computed Tomography when Evaluating the Distance to the Alveolar Nerve in the Site of Lateral Teeth Česaitienė, Gabrielė Česaitis, Kęstutis Junevičius, Jonas Venskutonis, Tadas Med Sci Monit Clinical Research BACKGROUND: The aim of this study was to compare the reliability of panoramic radiography (PR) and cone beam computed tomography (CBCT) in the evaluation of the distance of the roots of lateral teeth to the inferior alveolar nerve canal (IANC). MATERIAL/METHODS: 100 PR and 100 CBCT images that met the selection criteria were selected from the database. In PR images, the distances were measured using an electronic caliper with 0.01 mm accuracy and white light x-ray film reviewer. Actual values of the measurements were calculated taking into consideration the magnification used in PR images (130%). Measurements on CBCT images were performed using i-CAT Vision software. Statistical data analysis was performed using R software and applying Welch’s t-test and the Wilcoxon test. RESULTS: There was no statistically significant difference in the mean distance from the root of the second premolar and the mesial and distal roots of the first molar to the IANC between PR and CBCT images. The difference in the mean distance from the mesial and distal roots of the second and the third molars to the IANC measured in PR and CBCT images was statistically significant. CONCLUSIONS: PR may be uninformative or misleading when measuring the distance from the mesial and distal roots of the second and the third molars to the IANC. International Scientific Literature, Inc. 2017-07-04 /pmc/articles/PMC5507794/ /pubmed/28674379 http://dx.doi.org/10.12659/MSM.902083 Text en © Med Sci Monit, 2017 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Česaitienė, Gabrielė
Česaitis, Kęstutis
Junevičius, Jonas
Venskutonis, Tadas
The Reliability of Panoramic Radiography Versus Cone Beam Computed Tomography when Evaluating the Distance to the Alveolar Nerve in the Site of Lateral Teeth
title The Reliability of Panoramic Radiography Versus Cone Beam Computed Tomography when Evaluating the Distance to the Alveolar Nerve in the Site of Lateral Teeth
title_full The Reliability of Panoramic Radiography Versus Cone Beam Computed Tomography when Evaluating the Distance to the Alveolar Nerve in the Site of Lateral Teeth
title_fullStr The Reliability of Panoramic Radiography Versus Cone Beam Computed Tomography when Evaluating the Distance to the Alveolar Nerve in the Site of Lateral Teeth
title_full_unstemmed The Reliability of Panoramic Radiography Versus Cone Beam Computed Tomography when Evaluating the Distance to the Alveolar Nerve in the Site of Lateral Teeth
title_short The Reliability of Panoramic Radiography Versus Cone Beam Computed Tomography when Evaluating the Distance to the Alveolar Nerve in the Site of Lateral Teeth
title_sort reliability of panoramic radiography versus cone beam computed tomography when evaluating the distance to the alveolar nerve in the site of lateral teeth
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5507794/
https://www.ncbi.nlm.nih.gov/pubmed/28674379
http://dx.doi.org/10.12659/MSM.902083
work_keys_str_mv AT cesaitienegabriele thereliabilityofpanoramicradiographyversusconebeamcomputedtomographywhenevaluatingthedistancetothealveolarnerveinthesiteoflateralteeth
AT cesaitiskestutis thereliabilityofpanoramicradiographyversusconebeamcomputedtomographywhenevaluatingthedistancetothealveolarnerveinthesiteoflateralteeth
AT juneviciusjonas thereliabilityofpanoramicradiographyversusconebeamcomputedtomographywhenevaluatingthedistancetothealveolarnerveinthesiteoflateralteeth
AT venskutonistadas thereliabilityofpanoramicradiographyversusconebeamcomputedtomographywhenevaluatingthedistancetothealveolarnerveinthesiteoflateralteeth
AT cesaitienegabriele reliabilityofpanoramicradiographyversusconebeamcomputedtomographywhenevaluatingthedistancetothealveolarnerveinthesiteoflateralteeth
AT cesaitiskestutis reliabilityofpanoramicradiographyversusconebeamcomputedtomographywhenevaluatingthedistancetothealveolarnerveinthesiteoflateralteeth
AT juneviciusjonas reliabilityofpanoramicradiographyversusconebeamcomputedtomographywhenevaluatingthedistancetothealveolarnerveinthesiteoflateralteeth
AT venskutonistadas reliabilityofpanoramicradiographyversusconebeamcomputedtomographywhenevaluatingthedistancetothealveolarnerveinthesiteoflateralteeth