Cargando…
A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model
BACKGROUND: Fracture of the ilium is common orthopedic injury that often requires surgical stabilization in canine patients. Of the various methods of surgical stabilization available, application of a lateral bone plate to the ilium is the most common method of fixation. Many plating options are av...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5508706/ https://www.ncbi.nlm.nih.gov/pubmed/28705189 http://dx.doi.org/10.1186/s12917-017-1139-8 |
_version_ | 1783249924035444736 |
---|---|
author | Kenzig, Allison R Butler, James R Priddy, Lauren B Lacy, Kristen R Elder, Steven H |
author_facet | Kenzig, Allison R Butler, James R Priddy, Lauren B Lacy, Kristen R Elder, Steven H |
author_sort | Kenzig, Allison R |
collection | PubMed |
description | BACKGROUND: Fracture of the ilium is common orthopedic injury that often requires surgical stabilization in canine patients. Of the various methods of surgical stabilization available, application of a lateral bone plate to the ilium is the most common method of fixation. Many plating options are available, each having its own advantages and disadvantages. The purpose of this study was to evaluate the biomechanical properties of a 3.5 mm String-of-Pearls™ plate and a 3.5 mm dynamic compression plate in a cadaveric canine ilial fracture model. Hemipelves were tested in cantilever bending to failure and construct stiffness, yield load, displacement at yield, ultimate load, and mode of failure were compared. RESULTS: The mean stiffness of dynamic compression plate (116 ± 47 N/mm) and String-of-Pearls™ plate (107 ± 18 N/mm) constructs, mean yield load of dynamic compression plate (793 ± 333 N) and String-of-Pearls™ plate (860 ± 207 N) constructs, mean displacement at yield of dynamic compression plate (8.6 ± 3.0 mm) and String-of-Pearls™ plate (10.2 ± 2.8 mm) constructs, and ultimate load at failure of dynamic compression plate (936 ± 320 N) and String-of-Pearls™ plate (939 ± 191 N) constructs were not significantly different. No differences were found between constructs with respect to mode of failure. CONCLUSIONS: No significant biomechanical differences were found between String-of-Pearls™ plate and dynamic compression plate constructs in this simplified cadaveric canine ilial fracture model. |
format | Online Article Text |
id | pubmed-5508706 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-55087062017-07-17 A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model Kenzig, Allison R Butler, James R Priddy, Lauren B Lacy, Kristen R Elder, Steven H BMC Vet Res Research Article BACKGROUND: Fracture of the ilium is common orthopedic injury that often requires surgical stabilization in canine patients. Of the various methods of surgical stabilization available, application of a lateral bone plate to the ilium is the most common method of fixation. Many plating options are available, each having its own advantages and disadvantages. The purpose of this study was to evaluate the biomechanical properties of a 3.5 mm String-of-Pearls™ plate and a 3.5 mm dynamic compression plate in a cadaveric canine ilial fracture model. Hemipelves were tested in cantilever bending to failure and construct stiffness, yield load, displacement at yield, ultimate load, and mode of failure were compared. RESULTS: The mean stiffness of dynamic compression plate (116 ± 47 N/mm) and String-of-Pearls™ plate (107 ± 18 N/mm) constructs, mean yield load of dynamic compression plate (793 ± 333 N) and String-of-Pearls™ plate (860 ± 207 N) constructs, mean displacement at yield of dynamic compression plate (8.6 ± 3.0 mm) and String-of-Pearls™ plate (10.2 ± 2.8 mm) constructs, and ultimate load at failure of dynamic compression plate (936 ± 320 N) and String-of-Pearls™ plate (939 ± 191 N) constructs were not significantly different. No differences were found between constructs with respect to mode of failure. CONCLUSIONS: No significant biomechanical differences were found between String-of-Pearls™ plate and dynamic compression plate constructs in this simplified cadaveric canine ilial fracture model. BioMed Central 2017-07-13 /pmc/articles/PMC5508706/ /pubmed/28705189 http://dx.doi.org/10.1186/s12917-017-1139-8 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Kenzig, Allison R Butler, James R Priddy, Lauren B Lacy, Kristen R Elder, Steven H A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model |
title | A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model |
title_full | A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model |
title_fullStr | A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model |
title_full_unstemmed | A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model |
title_short | A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model |
title_sort | biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine ilial fracture model |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5508706/ https://www.ncbi.nlm.nih.gov/pubmed/28705189 http://dx.doi.org/10.1186/s12917-017-1139-8 |
work_keys_str_mv | AT kenzigallisonr abiomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel AT butlerjamesr abiomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel AT priddylaurenb abiomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel AT lacykristenr abiomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel AT elderstevenh abiomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel AT kenzigallisonr biomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel AT butlerjamesr biomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel AT priddylaurenb biomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel AT lacykristenr biomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel AT elderstevenh biomechanicalcomparisonofconventionaldynamiccompressionplatesandstringofpearlslockingplatesusingcantileverbendinginacanineilialfracturemodel |