Cargando…

Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure r...

Descripción completa

Detalles Bibliográficos
Autores principales: Guan, Ying, Wang, Lu, Lin, Jing, King, Martin W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5509269/
https://www.ncbi.nlm.nih.gov/pubmed/28773781
http://dx.doi.org/10.3390/ma9080658
_version_ 1783249995587125248
author Guan, Ying
Wang, Lu
Lin, Jing
King, Martin W.
author_facet Guan, Ying
Wang, Lu
Lin, Jing
King, Martin W.
author_sort Guan, Ying
collection PubMed
description Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU) and polyester graft (nitinol-PET) materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.
format Online
Article
Text
id pubmed-5509269
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-55092692017-07-28 Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones Guan, Ying Wang, Lu Lin, Jing King, Martin W. Materials (Basel) Article Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU) and polyester graft (nitinol-PET) materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft. MDPI 2016-08-05 /pmc/articles/PMC5509269/ /pubmed/28773781 http://dx.doi.org/10.3390/ma9080658 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Guan, Ying
Wang, Lu
Lin, Jing
King, Martin W.
Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones
title Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones
title_full Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones
title_fullStr Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones
title_full_unstemmed Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones
title_short Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones
title_sort compliance study of endovascular stent grafts incorporated with polyester and polyurethane graft materials in both stented and unstented zones
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5509269/
https://www.ncbi.nlm.nih.gov/pubmed/28773781
http://dx.doi.org/10.3390/ma9080658
work_keys_str_mv AT guanying compliancestudyofendovascularstentgraftsincorporatedwithpolyesterandpolyurethanegraftmaterialsinbothstentedandunstentedzones
AT wanglu compliancestudyofendovascularstentgraftsincorporatedwithpolyesterandpolyurethanegraftmaterialsinbothstentedandunstentedzones
AT linjing compliancestudyofendovascularstentgraftsincorporatedwithpolyesterandpolyurethanegraftmaterialsinbothstentedandunstentedzones
AT kingmartinw compliancestudyofendovascularstentgraftsincorporatedwithpolyesterandpolyurethanegraftmaterialsinbothstentedandunstentedzones