Cargando…

Preplanning prediction of the left anterior descending artery maximum dose based on patient, dosimetric, and treatment planning parameters

PURPOSE: Maximum dose to the left anterior descending artery (LADmax) is an important physical constraint to reduce the risk of cardiovascular toxicity. We generated a simple algorithm to guide the positioning of the tangent fields to reliably maintain LADmax <10 Gy. METHODS AND MATERIALS: Dosime...

Descripción completa

Detalles Bibliográficos
Autores principales: Cooper, Benjamin T., Li, Xiaochun, Shin, Samuel M., Modrek, Aram S., Hsu, Howard C., DeWyngaert, J.K., Jozsef, Gabor, Lymberis, Stella C., Goldberg, Judith D., Formenti, Silvia C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5514165/
https://www.ncbi.nlm.nih.gov/pubmed/28740908
http://dx.doi.org/10.1016/j.adro.2016.08.001
Descripción
Sumario:PURPOSE: Maximum dose to the left anterior descending artery (LADmax) is an important physical constraint to reduce the risk of cardiovascular toxicity. We generated a simple algorithm to guide the positioning of the tangent fields to reliably maintain LADmax <10 Gy. METHODS AND MATERIALS: Dosimetric plans from 146 consecutive women treated prone to the left breast enrolled in prospective protocols of accelerated whole breast radiation therapy, with a concomitant daily boost to the tumor bed (40.5 Gy/15 fraction to the whole breast and 48 Gy to the tumor bed), provided the training set for algorithm development. Scatter plots and correlation coefficients were used to describe the bivariate relationships between LADmax and several parameters: distance from the tumor cavity to the tangent field edge, cavity size, breast separation, field size, and distance from the tangent field. A logistic sigmoid curve was used to model the relationship of LADmax and the distance from the tangent field. Furthermore, we tested this prediction model on a validation data set of 53 consecutive similar patients. RESULTS: A lack of linear relationships between LADmax and distance from cavity to LAD (−0.47), cavity size (−0.18), breast separation (−0.02), or field size (−0.28) was observed. In contrast, distance from the tangent field was highly negatively correlated to LADmax (-0.84) and was used in the models to predict LADmax. From a logistic sigmoid model we selected a cut-point of 2.46 mm (95% confidence interval, 2.19-2.74 mm) greater than which LADmax is <10 Gy (95% confidence interval, 9.30-10.72 Gy) and LADmean is <3.3 Gy. CONCLUSIONS: Placing the edge of the tangents at least 2.5 mm from the closest point of the contoured LAD is likely to assure LADmax is <10 Gy and LADmean is <3.3 Gy in patients treated with prone accelerated breast radiation therapy.