Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study
BACKGROUND: The aim of this study was to evaluate the biomechanical response of the peri-implant bone to standard, short-wide, and double mini implants replacing missing molar supporting either hybrid ceramic crowns (Lava Ultimate restorative) or full-metal crowns under two different loading conditi...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5515718/ https://www.ncbi.nlm.nih.gov/pubmed/28721551 http://dx.doi.org/10.1186/s40729-017-0094-2 |
_version_ | 1783251019749130240 |
---|---|
author | Elfadaly, Lamiaa Said Khairallah, Lamiaa Sayed Al Agroudy, Mona Atteya |
author_facet | Elfadaly, Lamiaa Said Khairallah, Lamiaa Sayed Al Agroudy, Mona Atteya |
author_sort | Elfadaly, Lamiaa Said |
collection | PubMed |
description | BACKGROUND: The aim of this study was to evaluate the biomechanical response of the peri-implant bone to standard, short-wide, and double mini implants replacing missing molar supporting either hybrid ceramic crowns (Lava Ultimate restorative) or full-metal crowns under two different loading conditions (axial and off-axial loading) using strain gauge analysis. METHODS: Three single-molar implant designs, (1) single, 3.8-mm (regular) diameter implant, (2) single, 5.8-mm (wide) diameter implant, and (3) two 2.5-mm diameter (double) implants connected through a single-molar crown, were embedded in epoxy resin by the aid of a surveyor to ensure their parallelism. Each implant supported full-metal crowns made of Ni-Cr alloy and hybrid ceramic with standardized dimensions. Epoxy resin casts were prepared to receive 4 strain gauges around each implant design, on the buccal, lingual, mesial, and distal surfaces. Results were analyzed statistically. RESULTS: Results showed that implant design has statistically significant effect on peri-implant microstrains, where the standard implant showed the highest mean microstrain values followed by double mini implants, while the short-wide implant showed the lowest mean microstrain values. Concerning the superstructure material, implants supporting Lava Ultimate crowns had statistically significant higher mean microstrain values than those supporting full-metal crowns. Concerning the load direction, off-axial loading caused uneven distribution of load with statistically significant higher microstrain values on the site of off-axial loading (distal surface) than the axial loading. CONCLUSIONS: Implant design, superstructure material, and load direction significantly affect peri-implant microstrains. |
format | Online Article Text |
id | pubmed-5515718 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-55157182017-08-01 Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study Elfadaly, Lamiaa Said Khairallah, Lamiaa Sayed Al Agroudy, Mona Atteya Int J Implant Dent Research BACKGROUND: The aim of this study was to evaluate the biomechanical response of the peri-implant bone to standard, short-wide, and double mini implants replacing missing molar supporting either hybrid ceramic crowns (Lava Ultimate restorative) or full-metal crowns under two different loading conditions (axial and off-axial loading) using strain gauge analysis. METHODS: Three single-molar implant designs, (1) single, 3.8-mm (regular) diameter implant, (2) single, 5.8-mm (wide) diameter implant, and (3) two 2.5-mm diameter (double) implants connected through a single-molar crown, were embedded in epoxy resin by the aid of a surveyor to ensure their parallelism. Each implant supported full-metal crowns made of Ni-Cr alloy and hybrid ceramic with standardized dimensions. Epoxy resin casts were prepared to receive 4 strain gauges around each implant design, on the buccal, lingual, mesial, and distal surfaces. Results were analyzed statistically. RESULTS: Results showed that implant design has statistically significant effect on peri-implant microstrains, where the standard implant showed the highest mean microstrain values followed by double mini implants, while the short-wide implant showed the lowest mean microstrain values. Concerning the superstructure material, implants supporting Lava Ultimate crowns had statistically significant higher mean microstrain values than those supporting full-metal crowns. Concerning the load direction, off-axial loading caused uneven distribution of load with statistically significant higher microstrain values on the site of off-axial loading (distal surface) than the axial loading. CONCLUSIONS: Implant design, superstructure material, and load direction significantly affect peri-implant microstrains. Springer Berlin Heidelberg 2017-07-13 /pmc/articles/PMC5515718/ /pubmed/28721551 http://dx.doi.org/10.1186/s40729-017-0094-2 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Elfadaly, Lamiaa Said Khairallah, Lamiaa Sayed Al Agroudy, Mona Atteya Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study |
title | Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study |
title_full | Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study |
title_fullStr | Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study |
title_full_unstemmed | Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study |
title_short | Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study |
title_sort | peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5515718/ https://www.ncbi.nlm.nih.gov/pubmed/28721551 http://dx.doi.org/10.1186/s40729-017-0094-2 |
work_keys_str_mv | AT elfadalylamiaasaid periimplantbiomechanicalresponsestostandardshortwideanddoubleminiimplantsreplacingmissingmolarsupportinghybridceramicorfullmetalcrownsunderaxialandoffaxialloadinganinvitrostudy AT khairallahlamiaasayed periimplantbiomechanicalresponsestostandardshortwideanddoubleminiimplantsreplacingmissingmolarsupportinghybridceramicorfullmetalcrownsunderaxialandoffaxialloadinganinvitrostudy AT alagroudymonaatteya periimplantbiomechanicalresponsestostandardshortwideanddoubleminiimplantsreplacingmissingmolarsupportinghybridceramicorfullmetalcrownsunderaxialandoffaxialloadinganinvitrostudy |