Cargando…

Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

INTRODUCTION: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. AIM OF THE STUDY: The study was aimed at assessing the accuracy of measurem...

Descripción completa

Detalles Bibliográficos
Autores principales: Dresler, Maria Magdalena, Kociszewski, Jacek, Wlaźlak, Edyta, Pędraszewski, Piotr, Trzeciak, Agnieszka, Surkont, Grzegorz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medical Communications Sp. z o.o. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5516079/
https://www.ncbi.nlm.nih.gov/pubmed/28856017
http://dx.doi.org/10.15557/JoU.2017.0014
_version_ 1783251095810736128
author Dresler, Maria Magdalena
Kociszewski, Jacek
Wlaźlak, Edyta
Pędraszewski, Piotr
Trzeciak, Agnieszka
Surkont, Grzegorz
author_facet Dresler, Maria Magdalena
Kociszewski, Jacek
Wlaźlak, Edyta
Pędraszewski, Piotr
Trzeciak, Agnieszka
Surkont, Grzegorz
author_sort Dresler, Maria Magdalena
collection PubMed
description INTRODUCTION: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. AIM OF THE STUDY: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. MATERIAL AND METHODS: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. RESULTS: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. CONCLUSIONS: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.
format Online
Article
Text
id pubmed-5516079
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medical Communications Sp. z o.o.
record_format MEDLINE/PubMed
spelling pubmed-55160792017-08-30 Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe Dresler, Maria Magdalena Kociszewski, Jacek Wlaźlak, Edyta Pędraszewski, Piotr Trzeciak, Agnieszka Surkont, Grzegorz J Ultrason Original Paper INTRODUCTION: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. AIM OF THE STUDY: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. MATERIAL AND METHODS: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. RESULTS: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. CONCLUSIONS: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. Medical Communications Sp. z o.o. 2017-06-30 2017-06 /pmc/articles/PMC5516079/ /pubmed/28856017 http://dx.doi.org/10.15557/JoU.2017.0014 Text en 2017 Polish Ultrasound Society. Published by Medical Communications Sp. z o.o. All rights reserved. http://creativecommons.org/licenses/by-nc-nd This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License (CC BY-NC-ND). Reproduction is permitted for personal, educational, non-commercial use, provided that the original article is in whole, unmodified, and properly cited.
spellingShingle Original Paper
Dresler, Maria Magdalena
Kociszewski, Jacek
Wlaźlak, Edyta
Pędraszewski, Piotr
Trzeciak, Agnieszka
Surkont, Grzegorz
Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_full Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_fullStr Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_full_unstemmed Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_short Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
title_sort repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5516079/
https://www.ncbi.nlm.nih.gov/pubmed/28856017
http://dx.doi.org/10.15557/JoU.2017.0014
work_keys_str_mv AT dreslermariamagdalena repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT kociszewskijacek repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT wlazlakedyta repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT pedraszewskipiotr repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT trzeciakagnieszka repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe
AT surkontgrzegorz repeatabilityandreproducibilityofmeasurementsofthesuburethraltapelocationobtainedinpelvicfloorultrasoundperformedwithatransvaginalprobe