Cargando…

Comparison of Free-Beam- and Fiber-Type CO(2) Laser Delivery Systems in Stapes Surgery

BACKGROUND AND OBJECTIVES: A free-beam-type CO(2) laser, which use a micromanipulator mounted on a microscope as the delivery system, has the merit of not being affected by hand tremor at the time of shooting. However, this delivery system has several disadvantages, including a restricted operation...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Mun Young, Choi, Hyun Seok, Lee, Sang-Youp, Koo, Ja-Won
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Audiological Society 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5516696/
https://www.ncbi.nlm.nih.gov/pubmed/28704897
http://dx.doi.org/10.7874/jao.2017.21.2.103
Descripción
Sumario:BACKGROUND AND OBJECTIVES: A free-beam-type CO(2) laser, which use a micromanipulator mounted on a microscope as the delivery system, has the merit of not being affected by hand tremor at the time of shooting. However, this delivery system has several disadvantages, including a restricted operation range and a risk of incorrect focusing. A fiber-type CO(2) laser uses a hand-held delivery system and has the opposite merits and demerits. We compared the results of stapes surgery with free-beam and fiber type delivery systems. SUBJECTS AND METHODS: The study enrolled 36 patients who underwent stapedotomy with free-beam- (n=26) or fiber- (n=10) type CO(2) lasers. The air-bone (AB) gap closure, bone conduction (BC) change, and operating time were evaluated. The AB gap closure was calculated by subtracting the preoperative BC thresholds from the postoperative air conduction thresholds. The BC change was calculated by subtracting the postoperative BC thresholds from the preoperative BC thresholds. RESULTS: The mean operating time was significantly (p=0.035) shorter in the fiber-type group (72.5±8.2 min) than in the free-beam-type group (80.5±11.4 min). The mean AB gap closure did not differ significantly (p=0.297) between the free-beamand fiber-type groups (5.8±10.1 and 1.4±6.8 dB, respectively). The mean BC change did not differ significantly (p=0.873) between the free-beam- and fiber-type groups (2.4±6.9 and 2.8±5.3 dB, respectively). The hearing outcomes did not differ significantly between the two groups. CONCLUSIONS: Operating times were significantly shorter using the fiber-type CO(2) laser, while hearing outcomes did not differ significantly between the two groups.