Cargando…
The Use of Body Worn Sensors for Detecting the Vibrations Acting on the Lower Back in Alpine Ski Racing
This study explored the use of body worn sensors to evaluate the vibrations that act on the human body in alpine ski racing from a general and a back overuse injury prevention perspective. In the course of a biomechanical field experiment, six male European Cup-level athletes each performed two runs...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5517454/ https://www.ncbi.nlm.nih.gov/pubmed/28775695 http://dx.doi.org/10.3389/fphys.2017.00522 |
_version_ | 1783251288300978176 |
---|---|
author | Spörri, Jörg Kröll, Josef Fasel, Benedikt Aminian, Kamiar Müller, Erich |
author_facet | Spörri, Jörg Kröll, Josef Fasel, Benedikt Aminian, Kamiar Müller, Erich |
author_sort | Spörri, Jörg |
collection | PubMed |
description | This study explored the use of body worn sensors to evaluate the vibrations that act on the human body in alpine ski racing from a general and a back overuse injury prevention perspective. In the course of a biomechanical field experiment, six male European Cup-level athletes each performed two runs on a typical giant slalom (GS) and slalom (SL) course, resulting in a total of 192 analyzed turns. Three-dimensional accelerations were measured by six inertial measurement units placed on the right and left shanks, right and left thighs, sacrum, and sternum. Based on these data, power spectral density (PSD; i.e., the signal's power distribution over frequency) was determined for all segments analyzed. Additionally, as a measure expressing the severity of vibration exposure, root-mean-square (RMS) acceleration acting on the lower back was calculated based on the inertial acceleration along the sacrum's longitudinal axis. In both GS and SL skiing, the PSD values of the vibrations acting at the shank were found to be largest for frequencies below 30 Hz. While being transmitted through the body, these vibrations were successively attenuated by the knee and hip joint. At the lower back (i.e., sacrum sensor), PSD values were especially pronounced for frequencies between 4 and 10 Hz, whereas a corresponding comparison between GS and SL revealed higher PSD values and larger RMS values for GS. Because vibrations in this particular range (i.e., 4 to 10 Hz) include the spine's resonant frequency and are known to increase the risk of structural deteriorations/abnormalities of the spine, they may be considered potential components of mechanisms leading to overuse injuries of the back in alpine ski racing. Accordingly, any measure to control and/or reduce such skiing-related vibrations to a minimum should be recognized and applied. In this connection, wearable sensor technologies might help to better monitor and manage the overall back overuse-relevant vibration exposure of athletes in regular training and or competition settings in the near future. |
format | Online Article Text |
id | pubmed-5517454 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-55174542017-08-03 The Use of Body Worn Sensors for Detecting the Vibrations Acting on the Lower Back in Alpine Ski Racing Spörri, Jörg Kröll, Josef Fasel, Benedikt Aminian, Kamiar Müller, Erich Front Physiol Physiology This study explored the use of body worn sensors to evaluate the vibrations that act on the human body in alpine ski racing from a general and a back overuse injury prevention perspective. In the course of a biomechanical field experiment, six male European Cup-level athletes each performed two runs on a typical giant slalom (GS) and slalom (SL) course, resulting in a total of 192 analyzed turns. Three-dimensional accelerations were measured by six inertial measurement units placed on the right and left shanks, right and left thighs, sacrum, and sternum. Based on these data, power spectral density (PSD; i.e., the signal's power distribution over frequency) was determined for all segments analyzed. Additionally, as a measure expressing the severity of vibration exposure, root-mean-square (RMS) acceleration acting on the lower back was calculated based on the inertial acceleration along the sacrum's longitudinal axis. In both GS and SL skiing, the PSD values of the vibrations acting at the shank were found to be largest for frequencies below 30 Hz. While being transmitted through the body, these vibrations were successively attenuated by the knee and hip joint. At the lower back (i.e., sacrum sensor), PSD values were especially pronounced for frequencies between 4 and 10 Hz, whereas a corresponding comparison between GS and SL revealed higher PSD values and larger RMS values for GS. Because vibrations in this particular range (i.e., 4 to 10 Hz) include the spine's resonant frequency and are known to increase the risk of structural deteriorations/abnormalities of the spine, they may be considered potential components of mechanisms leading to overuse injuries of the back in alpine ski racing. Accordingly, any measure to control and/or reduce such skiing-related vibrations to a minimum should be recognized and applied. In this connection, wearable sensor technologies might help to better monitor and manage the overall back overuse-relevant vibration exposure of athletes in regular training and or competition settings in the near future. Frontiers Media S.A. 2017-07-20 /pmc/articles/PMC5517454/ /pubmed/28775695 http://dx.doi.org/10.3389/fphys.2017.00522 Text en Copyright © 2017 Spörri, Kröll, Fasel, Aminian and Müller. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Spörri, Jörg Kröll, Josef Fasel, Benedikt Aminian, Kamiar Müller, Erich The Use of Body Worn Sensors for Detecting the Vibrations Acting on the Lower Back in Alpine Ski Racing |
title | The Use of Body Worn Sensors for Detecting the Vibrations Acting on the Lower Back in Alpine Ski Racing |
title_full | The Use of Body Worn Sensors for Detecting the Vibrations Acting on the Lower Back in Alpine Ski Racing |
title_fullStr | The Use of Body Worn Sensors for Detecting the Vibrations Acting on the Lower Back in Alpine Ski Racing |
title_full_unstemmed | The Use of Body Worn Sensors for Detecting the Vibrations Acting on the Lower Back in Alpine Ski Racing |
title_short | The Use of Body Worn Sensors for Detecting the Vibrations Acting on the Lower Back in Alpine Ski Racing |
title_sort | use of body worn sensors for detecting the vibrations acting on the lower back in alpine ski racing |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5517454/ https://www.ncbi.nlm.nih.gov/pubmed/28775695 http://dx.doi.org/10.3389/fphys.2017.00522 |
work_keys_str_mv | AT sporrijorg theuseofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing AT krolljosef theuseofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing AT faselbenedikt theuseofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing AT aminiankamiar theuseofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing AT mullererich theuseofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing AT sporrijorg useofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing AT krolljosef useofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing AT faselbenedikt useofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing AT aminiankamiar useofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing AT mullererich useofbodywornsensorsfordetectingthevibrationsactingonthelowerbackinalpineskiracing |