Cargando…
Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
We report the observation of the electrochemically generated nitrenium ions of 4,4′-dimethyoxydiphenylamine and di-p-tolylamine in solution by mass spectrometry. This setup takes inspiration from desorption electrospray ionization mass spectrometry to sample directly from the surface of a rotating w...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Royal Society of Chemistry
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5518571/ https://www.ncbi.nlm.nih.gov/pubmed/28791096 http://dx.doi.org/10.1039/c5sc02939b |
_version_ | 1783251514734673920 |
---|---|
author | Brown, Timothy A. Hosseini-Nassab, Niloufar Chen, Hao Zare, Richard N. |
author_facet | Brown, Timothy A. Hosseini-Nassab, Niloufar Chen, Hao Zare, Richard N. |
author_sort | Brown, Timothy A. |
collection | PubMed |
description | We report the observation of the electrochemically generated nitrenium ions of 4,4′-dimethyoxydiphenylamine and di-p-tolylamine in solution by mass spectrometry. This setup takes inspiration from desorption electrospray ionization mass spectrometry to sample directly from the surface of a rotating waterwheel working electrode for mass spectrometric analysis. Detection of the 4,4′-dimethyoxydiphenylamine nitrenium ion was expected based upon para-methoxy resonance stabilization, whereas observation of the di-p-tolylamine nitrenium ion might be unexpected because resonance stabilization from the para-substituted position is unavailable. However, the short timescale analysis of the setup allows for the isolation of the di-p-tolylamine nitrenium ion, which is electrogenerated in solution and detected mass spectrometrically. |
format | Online Article Text |
id | pubmed-5518571 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-55185712017-08-08 Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry Brown, Timothy A. Hosseini-Nassab, Niloufar Chen, Hao Zare, Richard N. Chem Sci Chemistry We report the observation of the electrochemically generated nitrenium ions of 4,4′-dimethyoxydiphenylamine and di-p-tolylamine in solution by mass spectrometry. This setup takes inspiration from desorption electrospray ionization mass spectrometry to sample directly from the surface of a rotating waterwheel working electrode for mass spectrometric analysis. Detection of the 4,4′-dimethyoxydiphenylamine nitrenium ion was expected based upon para-methoxy resonance stabilization, whereas observation of the di-p-tolylamine nitrenium ion might be unexpected because resonance stabilization from the para-substituted position is unavailable. However, the short timescale analysis of the setup allows for the isolation of the di-p-tolylamine nitrenium ion, which is electrogenerated in solution and detected mass spectrometrically. Royal Society of Chemistry 2016-01-01 2015-10-08 /pmc/articles/PMC5518571/ /pubmed/28791096 http://dx.doi.org/10.1039/c5sc02939b Text en This journal is © The Royal Society of Chemistry 2015 http://creativecommons.org/licenses/by/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution 3.0 Unported License (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Chemistry Brown, Timothy A. Hosseini-Nassab, Niloufar Chen, Hao Zare, Richard N. Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry |
title | Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
|
title_full | Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
|
title_fullStr | Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
|
title_full_unstemmed | Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
|
title_short | Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
|
title_sort | observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5518571/ https://www.ncbi.nlm.nih.gov/pubmed/28791096 http://dx.doi.org/10.1039/c5sc02939b |
work_keys_str_mv | AT browntimothya observationofelectrochemicallygeneratednitreniumionsbydesorptionelectrosprayionizationmassspectrometry AT hosseininassabniloufar observationofelectrochemicallygeneratednitreniumionsbydesorptionelectrosprayionizationmassspectrometry AT chenhao observationofelectrochemicallygeneratednitreniumionsbydesorptionelectrosprayionizationmassspectrometry AT zarerichardn observationofelectrochemicallygeneratednitreniumionsbydesorptionelectrosprayionizationmassspectrometry |