Cargando…

Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry

We report the observation of the electrochemically generated nitrenium ions of 4,4′-dimethyoxydiphenylamine and di-p-tolylamine in solution by mass spectrometry. This setup takes inspiration from desorption electrospray ionization mass spectrometry to sample directly from the surface of a rotating w...

Descripción completa

Detalles Bibliográficos
Autores principales: Brown, Timothy A., Hosseini-Nassab, Niloufar, Chen, Hao, Zare, Richard N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Royal Society of Chemistry 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5518571/
https://www.ncbi.nlm.nih.gov/pubmed/28791096
http://dx.doi.org/10.1039/c5sc02939b
_version_ 1783251514734673920
author Brown, Timothy A.
Hosseini-Nassab, Niloufar
Chen, Hao
Zare, Richard N.
author_facet Brown, Timothy A.
Hosseini-Nassab, Niloufar
Chen, Hao
Zare, Richard N.
author_sort Brown, Timothy A.
collection PubMed
description We report the observation of the electrochemically generated nitrenium ions of 4,4′-dimethyoxydiphenylamine and di-p-tolylamine in solution by mass spectrometry. This setup takes inspiration from desorption electrospray ionization mass spectrometry to sample directly from the surface of a rotating waterwheel working electrode for mass spectrometric analysis. Detection of the 4,4′-dimethyoxydiphenylamine nitrenium ion was expected based upon para-methoxy resonance stabilization, whereas observation of the di-p-tolylamine nitrenium ion might be unexpected because resonance stabilization from the para-substituted position is unavailable. However, the short timescale analysis of the setup allows for the isolation of the di-p-tolylamine nitrenium ion, which is electrogenerated in solution and detected mass spectrometrically.
format Online
Article
Text
id pubmed-5518571
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-55185712017-08-08 Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry Brown, Timothy A. Hosseini-Nassab, Niloufar Chen, Hao Zare, Richard N. Chem Sci Chemistry We report the observation of the electrochemically generated nitrenium ions of 4,4′-dimethyoxydiphenylamine and di-p-tolylamine in solution by mass spectrometry. This setup takes inspiration from desorption electrospray ionization mass spectrometry to sample directly from the surface of a rotating waterwheel working electrode for mass spectrometric analysis. Detection of the 4,4′-dimethyoxydiphenylamine nitrenium ion was expected based upon para-methoxy resonance stabilization, whereas observation of the di-p-tolylamine nitrenium ion might be unexpected because resonance stabilization from the para-substituted position is unavailable. However, the short timescale analysis of the setup allows for the isolation of the di-p-tolylamine nitrenium ion, which is electrogenerated in solution and detected mass spectrometrically. Royal Society of Chemistry 2016-01-01 2015-10-08 /pmc/articles/PMC5518571/ /pubmed/28791096 http://dx.doi.org/10.1039/c5sc02939b Text en This journal is © The Royal Society of Chemistry 2015 http://creativecommons.org/licenses/by/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution 3.0 Unported License (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Chemistry
Brown, Timothy A.
Hosseini-Nassab, Niloufar
Chen, Hao
Zare, Richard N.
Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
title Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
title_full Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
title_fullStr Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
title_full_unstemmed Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
title_short Observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
title_sort observation of electrochemically generated nitrenium ions by desorption electrospray ionization mass spectrometry
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5518571/
https://www.ncbi.nlm.nih.gov/pubmed/28791096
http://dx.doi.org/10.1039/c5sc02939b
work_keys_str_mv AT browntimothya observationofelectrochemicallygeneratednitreniumionsbydesorptionelectrosprayionizationmassspectrometry
AT hosseininassabniloufar observationofelectrochemicallygeneratednitreniumionsbydesorptionelectrosprayionizationmassspectrometry
AT chenhao observationofelectrochemicallygeneratednitreniumionsbydesorptionelectrosprayionizationmassspectrometry
AT zarerichardn observationofelectrochemicallygeneratednitreniumionsbydesorptionelectrosprayionizationmassspectrometry