Computed tomography angiography for imaging results of neochordal mitral valve repair

INTRODUCTION: Degenerative mitral regurgitation is currently the most frequent indication for mitral valve repair. AIM: To visualize and assess the mid-term results of mitral valve repair with neochordae implantation, using computed tomography angiography (CTA) imaging. MATERIAL AND METHODS: The CTA...

Descripción completa

Detalles Bibliográficos
Autores principales: Zwoliński, Radosław, Marcinkiewicz, Anna, Szymczyk, Konrad, Drożdż, Jarosław, Jaszewski, Ryszard, Jegier, Bogdan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5519832/
https://www.ncbi.nlm.nih.gov/pubmed/28747938
http://dx.doi.org/10.5114/kitp.2017.68736
_version_ 1783251703132323840
author Zwoliński, Radosław
Marcinkiewicz, Anna
Szymczyk, Konrad
Drożdż, Jarosław
Jaszewski, Ryszard
Jegier, Bogdan
author_facet Zwoliński, Radosław
Marcinkiewicz, Anna
Szymczyk, Konrad
Drożdż, Jarosław
Jaszewski, Ryszard
Jegier, Bogdan
author_sort Zwoliński, Radosław
collection PubMed
description INTRODUCTION: Degenerative mitral regurgitation is currently the most frequent indication for mitral valve repair. AIM: To visualize and assess the mid-term results of mitral valve repair with neochordae implantation, using computed tomography angiography (CTA) imaging. MATERIAL AND METHODS: The CTA with ECG gating and without modulation was applied in 10 patients to assess the results of a mitral valve sparing procedure. The results of 3 patients are presented. The patients were operated on for severe symptomatic degenerative mitral regurgitation, defined according to a modified Carpentier’s functional classification. RESULTS: Neochordal repair, by placing expanded polytetrafluoroethylene sutures between the leading edge of the prolapsing segment and the corresponding papillary muscle, was conducted. From 1 to 3 double Gore-Tex loops were used. Leaflet clefts, if present, were sutured. All repairs included mitral valve ring annuloplasty. The CTA was performed at 20–24 months after the surgery. Long-axis views, reconstructed during mid-systole, seemed to be the most valuable. Good quality cardiac images, precisely presenting the mitral valve complex with its constituents, were obtained in the case of patients without obesity, with a relatively small anterior-posterior thorax dimension, with sinus, slow heart rhythm and quite good left ventricle contractility. The evaluation of the mitral valve included presence of calcifications, fibrosis or thickening, chordal insertion and coaptation points, and papillary muscle locations. Primary and secondary native chordae tendineae and artificial chordae were visualized. CONCLUSIONS: Contrast material-enhanced ECG-gated CTA applied after mitral valve repair with Gore-Tex neochordae allows one to obtain satisfactory mitral valve images, especially during mid-systole, and evaluate mid-term results of the surgery in chosen patients.
format Online
Article
Text
id pubmed-5519832
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-55198322017-07-26 Computed tomography angiography for imaging results of neochordal mitral valve repair Zwoliński, Radosław Marcinkiewicz, Anna Szymczyk, Konrad Drożdż, Jarosław Jaszewski, Ryszard Jegier, Bogdan Kardiochir Torakochirurgia Pol Original Paper INTRODUCTION: Degenerative mitral regurgitation is currently the most frequent indication for mitral valve repair. AIM: To visualize and assess the mid-term results of mitral valve repair with neochordae implantation, using computed tomography angiography (CTA) imaging. MATERIAL AND METHODS: The CTA with ECG gating and without modulation was applied in 10 patients to assess the results of a mitral valve sparing procedure. The results of 3 patients are presented. The patients were operated on for severe symptomatic degenerative mitral regurgitation, defined according to a modified Carpentier’s functional classification. RESULTS: Neochordal repair, by placing expanded polytetrafluoroethylene sutures between the leading edge of the prolapsing segment and the corresponding papillary muscle, was conducted. From 1 to 3 double Gore-Tex loops were used. Leaflet clefts, if present, were sutured. All repairs included mitral valve ring annuloplasty. The CTA was performed at 20–24 months after the surgery. Long-axis views, reconstructed during mid-systole, seemed to be the most valuable. Good quality cardiac images, precisely presenting the mitral valve complex with its constituents, were obtained in the case of patients without obesity, with a relatively small anterior-posterior thorax dimension, with sinus, slow heart rhythm and quite good left ventricle contractility. The evaluation of the mitral valve included presence of calcifications, fibrosis or thickening, chordal insertion and coaptation points, and papillary muscle locations. Primary and secondary native chordae tendineae and artificial chordae were visualized. CONCLUSIONS: Contrast material-enhanced ECG-gated CTA applied after mitral valve repair with Gore-Tex neochordae allows one to obtain satisfactory mitral valve images, especially during mid-systole, and evaluate mid-term results of the surgery in chosen patients. Termedia Publishing House 2017-06-30 2017-06 /pmc/articles/PMC5519832/ /pubmed/28747938 http://dx.doi.org/10.5114/kitp.2017.68736 Text en Copyright: © 2017 Polish Society of Cardiothoracic Surgeons (Polskie Towarzystwo KardioTorakochirurgów) and the editors of the Polish Journal of Cardio-Thoracic Surgery (Kardiochirurgia i Torakochirurgia Polska) http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original Paper
Zwoliński, Radosław
Marcinkiewicz, Anna
Szymczyk, Konrad
Drożdż, Jarosław
Jaszewski, Ryszard
Jegier, Bogdan
Computed tomography angiography for imaging results of neochordal mitral valve repair
title Computed tomography angiography for imaging results of neochordal mitral valve repair
title_full Computed tomography angiography for imaging results of neochordal mitral valve repair
title_fullStr Computed tomography angiography for imaging results of neochordal mitral valve repair
title_full_unstemmed Computed tomography angiography for imaging results of neochordal mitral valve repair
title_short Computed tomography angiography for imaging results of neochordal mitral valve repair
title_sort computed tomography angiography for imaging results of neochordal mitral valve repair
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5519832/
https://www.ncbi.nlm.nih.gov/pubmed/28747938
http://dx.doi.org/10.5114/kitp.2017.68736
work_keys_str_mv AT zwolinskiradosław computedtomographyangiographyforimagingresultsofneochordalmitralvalverepair
AT marcinkiewiczanna computedtomographyangiographyforimagingresultsofneochordalmitralvalverepair
AT szymczykkonrad computedtomographyangiographyforimagingresultsofneochordalmitralvalverepair
AT drozdzjarosław computedtomographyangiographyforimagingresultsofneochordalmitralvalverepair
AT jaszewskiryszard computedtomographyangiographyforimagingresultsofneochordalmitralvalverepair
AT jegierbogdan computedtomographyangiographyforimagingresultsofneochordalmitralvalverepair