Cargando…
Effect of different nickel-titanium rotary files on dentinal crack formation during retreatment procedure
Background. The aim of this study was to compare the dentinal defects caused by Reciproc, TF Adaptive and ProTaper Next NiTi rotary file systems during the retreatment procedure. Methods. A total of 150 mandibular incisors with straight and single root canals were included in the present study. All...
Autores principales: | Çitak, Mehmet, Özyürek, Taha |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tabriz University of Medical Sciences
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5519999/ https://www.ncbi.nlm.nih.gov/pubmed/28748049 http://dx.doi.org/10.15171/joddd.2017.017 |
Ejemplares similares
-
The potential effect of instrumentation with different nickel titanium rotary systems on dentinal crack formation—An in vitro study
por: Fráter, Márk, et al.
Publicado: (2020) -
Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature
por: Uslu, Gülşah, et al.
Publicado: (2018) -
Evaluation of remaining dentin thickness following use of three different rotary nickel–titanium retreatment files: A cone-beam computed tomography study
por: Kulkarni, Nishita Rajeev, et al.
Publicado: (2019) -
Improved dentin disinfection by combining different-geometry rotary nickel-titanium files in preparing root canals
por: Bedier, Marwa M., et al.
Publicado: (2018) -
Assessment of Root Dentin Defect during Retreatment Procedure using Various NiTi Hand and Rotary Retreatment Files: An In vitro Study
por: Das, Maneesha, et al.
Publicado: (2022)