Cargando…

A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation

BACKGROUND AND AIMS: Many cases of difficult tracheal intubation remain unrecognized until after induction of anesthesia. McGrath and Airtraq videolaryngoscopes are among the novel laryngoscopes that have an advantage over the conventional laryngoscopes in case of unanticipated difficult airway. Thu...

Descripción completa

Detalles Bibliográficos
Autores principales: Raza, Nadeem, Hasan, Muazzam, Ahmed, Syed Moeid, Bano, Shahjahan, Athar, Manazir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5520596/
https://www.ncbi.nlm.nih.gov/pubmed/28781449
http://dx.doi.org/10.4103/joacp.JOACP_370_15
_version_ 1783251840468516864
author Raza, Nadeem
Hasan, Muazzam
Ahmed, Syed Moeid
Bano, Shahjahan
Athar, Manazir
author_facet Raza, Nadeem
Hasan, Muazzam
Ahmed, Syed Moeid
Bano, Shahjahan
Athar, Manazir
author_sort Raza, Nadeem
collection PubMed
description BACKGROUND AND AIMS: Many cases of difficult tracheal intubation remain unrecognized until after induction of anesthesia. McGrath and Airtraq videolaryngoscopes are among the novel laryngoscopes that have an advantage over the conventional laryngoscopes in case of unanticipated difficult airway. Thus, we did a comparative study between McGrath and Airtraq videolaryngoscopes to evaluate their efficacy in routine anesthesia practice. MATERIAL AND METHODS: Sixty anesthetized patients were divided into two groups using computer-based randomization, and tracheal intubation was performed using either McGrath or Airtraq laryngoscope. The primary outcome measures were duration and incidence of successful tracheal intubation. Hemodynamic response, glottic view (percentage of glottic opening score [POGO]), ease of intubation, and airway complications were also measured. RESULTS: Both McGrath and Airtraq groups were comparable in terms of incidence of successful tracheal intubation (93.3% vs. 96.6%), ease of intubation (70% vs. 77%), and POGO scoring. Intubation time was significantly shorter with Airtraq (13.5 vs. 17.8 s; P < 0.001). There were statistically significant changes in the heart rate and blood pressure after tracheal intubation in both the groups (P < 0.001); however, these parameters reached baseline within 5 min of intubation in both the groups. The incidence of injury was 10% with McGrath videolaryngoscope and 13.3% with Airtraq and was comparable. CONCLUSION: Both Airtraq and McGrath videolaryngoscope have high success rates of intubation. Airtraq is better than McGrath laryngoscope due to shorter tracheal intubation time.
format Online
Article
Text
id pubmed-5520596
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-55205962017-08-04 A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation Raza, Nadeem Hasan, Muazzam Ahmed, Syed Moeid Bano, Shahjahan Athar, Manazir J Anaesthesiol Clin Pharmacol Original Article BACKGROUND AND AIMS: Many cases of difficult tracheal intubation remain unrecognized until after induction of anesthesia. McGrath and Airtraq videolaryngoscopes are among the novel laryngoscopes that have an advantage over the conventional laryngoscopes in case of unanticipated difficult airway. Thus, we did a comparative study between McGrath and Airtraq videolaryngoscopes to evaluate their efficacy in routine anesthesia practice. MATERIAL AND METHODS: Sixty anesthetized patients were divided into two groups using computer-based randomization, and tracheal intubation was performed using either McGrath or Airtraq laryngoscope. The primary outcome measures were duration and incidence of successful tracheal intubation. Hemodynamic response, glottic view (percentage of glottic opening score [POGO]), ease of intubation, and airway complications were also measured. RESULTS: Both McGrath and Airtraq groups were comparable in terms of incidence of successful tracheal intubation (93.3% vs. 96.6%), ease of intubation (70% vs. 77%), and POGO scoring. Intubation time was significantly shorter with Airtraq (13.5 vs. 17.8 s; P < 0.001). There were statistically significant changes in the heart rate and blood pressure after tracheal intubation in both the groups (P < 0.001); however, these parameters reached baseline within 5 min of intubation in both the groups. The incidence of injury was 10% with McGrath videolaryngoscope and 13.3% with Airtraq and was comparable. CONCLUSION: Both Airtraq and McGrath videolaryngoscope have high success rates of intubation. Airtraq is better than McGrath laryngoscope due to shorter tracheal intubation time. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5520596/ /pubmed/28781449 http://dx.doi.org/10.4103/joacp.JOACP_370_15 Text en Copyright: © 2017 Journal of Anaesthesiology Clinical Pharmacology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Raza, Nadeem
Hasan, Muazzam
Ahmed, Syed Moeid
Bano, Shahjahan
Athar, Manazir
A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation
title A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation
title_full A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation
title_fullStr A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation
title_full_unstemmed A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation
title_short A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation
title_sort comparative study of mcgrath and airtraq videolaryngoscopes for tracheal intubation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5520596/
https://www.ncbi.nlm.nih.gov/pubmed/28781449
http://dx.doi.org/10.4103/joacp.JOACP_370_15
work_keys_str_mv AT razanadeem acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation
AT hasanmuazzam acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation
AT ahmedsyedmoeid acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation
AT banoshahjahan acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation
AT atharmanazir acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation
AT razanadeem comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation
AT hasanmuazzam comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation
AT ahmedsyedmoeid comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation
AT banoshahjahan comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation
AT atharmanazir comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation