Cargando…
A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation
BACKGROUND AND AIMS: Many cases of difficult tracheal intubation remain unrecognized until after induction of anesthesia. McGrath and Airtraq videolaryngoscopes are among the novel laryngoscopes that have an advantage over the conventional laryngoscopes in case of unanticipated difficult airway. Thu...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5520596/ https://www.ncbi.nlm.nih.gov/pubmed/28781449 http://dx.doi.org/10.4103/joacp.JOACP_370_15 |
_version_ | 1783251840468516864 |
---|---|
author | Raza, Nadeem Hasan, Muazzam Ahmed, Syed Moeid Bano, Shahjahan Athar, Manazir |
author_facet | Raza, Nadeem Hasan, Muazzam Ahmed, Syed Moeid Bano, Shahjahan Athar, Manazir |
author_sort | Raza, Nadeem |
collection | PubMed |
description | BACKGROUND AND AIMS: Many cases of difficult tracheal intubation remain unrecognized until after induction of anesthesia. McGrath and Airtraq videolaryngoscopes are among the novel laryngoscopes that have an advantage over the conventional laryngoscopes in case of unanticipated difficult airway. Thus, we did a comparative study between McGrath and Airtraq videolaryngoscopes to evaluate their efficacy in routine anesthesia practice. MATERIAL AND METHODS: Sixty anesthetized patients were divided into two groups using computer-based randomization, and tracheal intubation was performed using either McGrath or Airtraq laryngoscope. The primary outcome measures were duration and incidence of successful tracheal intubation. Hemodynamic response, glottic view (percentage of glottic opening score [POGO]), ease of intubation, and airway complications were also measured. RESULTS: Both McGrath and Airtraq groups were comparable in terms of incidence of successful tracheal intubation (93.3% vs. 96.6%), ease of intubation (70% vs. 77%), and POGO scoring. Intubation time was significantly shorter with Airtraq (13.5 vs. 17.8 s; P < 0.001). There were statistically significant changes in the heart rate and blood pressure after tracheal intubation in both the groups (P < 0.001); however, these parameters reached baseline within 5 min of intubation in both the groups. The incidence of injury was 10% with McGrath videolaryngoscope and 13.3% with Airtraq and was comparable. CONCLUSION: Both Airtraq and McGrath videolaryngoscope have high success rates of intubation. Airtraq is better than McGrath laryngoscope due to shorter tracheal intubation time. |
format | Online Article Text |
id | pubmed-5520596 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-55205962017-08-04 A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation Raza, Nadeem Hasan, Muazzam Ahmed, Syed Moeid Bano, Shahjahan Athar, Manazir J Anaesthesiol Clin Pharmacol Original Article BACKGROUND AND AIMS: Many cases of difficult tracheal intubation remain unrecognized until after induction of anesthesia. McGrath and Airtraq videolaryngoscopes are among the novel laryngoscopes that have an advantage over the conventional laryngoscopes in case of unanticipated difficult airway. Thus, we did a comparative study between McGrath and Airtraq videolaryngoscopes to evaluate their efficacy in routine anesthesia practice. MATERIAL AND METHODS: Sixty anesthetized patients were divided into two groups using computer-based randomization, and tracheal intubation was performed using either McGrath or Airtraq laryngoscope. The primary outcome measures were duration and incidence of successful tracheal intubation. Hemodynamic response, glottic view (percentage of glottic opening score [POGO]), ease of intubation, and airway complications were also measured. RESULTS: Both McGrath and Airtraq groups were comparable in terms of incidence of successful tracheal intubation (93.3% vs. 96.6%), ease of intubation (70% vs. 77%), and POGO scoring. Intubation time was significantly shorter with Airtraq (13.5 vs. 17.8 s; P < 0.001). There were statistically significant changes in the heart rate and blood pressure after tracheal intubation in both the groups (P < 0.001); however, these parameters reached baseline within 5 min of intubation in both the groups. The incidence of injury was 10% with McGrath videolaryngoscope and 13.3% with Airtraq and was comparable. CONCLUSION: Both Airtraq and McGrath videolaryngoscope have high success rates of intubation. Airtraq is better than McGrath laryngoscope due to shorter tracheal intubation time. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5520596/ /pubmed/28781449 http://dx.doi.org/10.4103/joacp.JOACP_370_15 Text en Copyright: © 2017 Journal of Anaesthesiology Clinical Pharmacology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Raza, Nadeem Hasan, Muazzam Ahmed, Syed Moeid Bano, Shahjahan Athar, Manazir A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation |
title | A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation |
title_full | A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation |
title_fullStr | A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation |
title_full_unstemmed | A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation |
title_short | A comparative study of McGrath and Airtraq videolaryngoscopes for tracheal intubation |
title_sort | comparative study of mcgrath and airtraq videolaryngoscopes for tracheal intubation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5520596/ https://www.ncbi.nlm.nih.gov/pubmed/28781449 http://dx.doi.org/10.4103/joacp.JOACP_370_15 |
work_keys_str_mv | AT razanadeem acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation AT hasanmuazzam acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation AT ahmedsyedmoeid acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation AT banoshahjahan acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation AT atharmanazir acomparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation AT razanadeem comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation AT hasanmuazzam comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation AT ahmedsyedmoeid comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation AT banoshahjahan comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation AT atharmanazir comparativestudyofmcgrathandairtraqvideolaryngoscopesfortrachealintubation |