Cargando…

Intraoperative Radiation Exposure During Hip Arthroscopy

BACKGROUND: The frequency of hip arthroscopy for the treatment of acute and chronic chondrolabral pathology and femoroacetabular impingement (FAI) has increased exponentially over the past decade. While surgeon and patient radiation exposure has been well documented in other areas of the orthopaedic...

Descripción completa

Detalles Bibliográficos
Autores principales: Salvo, John P., Zarah, Jake, Chaudhry, Zaira S., Poehling-Monaghan, Kirsten L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
53
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5524238/
https://www.ncbi.nlm.nih.gov/pubmed/28795076
http://dx.doi.org/10.1177/2325967117719014
_version_ 1783252433813635072
author Salvo, John P.
Zarah, Jake
Chaudhry, Zaira S.
Poehling-Monaghan, Kirsten L.
author_facet Salvo, John P.
Zarah, Jake
Chaudhry, Zaira S.
Poehling-Monaghan, Kirsten L.
author_sort Salvo, John P.
collection PubMed
description BACKGROUND: The frequency of hip arthroscopy for the treatment of acute and chronic chondrolabral pathology and femoroacetabular impingement (FAI) has increased exponentially over the past decade. While surgeon and patient radiation exposure has been well documented in other areas of the orthopaedic literature, little is known about the procedure-specific and cumulative doses affecting the hip arthroscopist. PURPOSE: To determine the mean annual radiation exposure to the hip arthroscopist and the mean surgeon exposure per case. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A total of 210 consecutive hip arthroscopies performed in 209 patients by a single surgeon at a single ambulatory surgical center in a cohort consisting of approximately 50% bony (cam and pincer) pathology were prospectively reviewed, documenting the specific procedures performed in each case and the readings from a radiation dosimeter worn by the surgeon during positioning and while performing the procedures. Radiation readings for deep dose–equivalent (DDE), lens dose–equivalent (LDE), and shallow dose–equivalent (SDE) were measured. These readings were compared with the annual radiation dose limit recommendations established by the International Commission on Radiological Protection (ICRP). RESULTS: The total radiation doses for the operative surgeon during all 210 cases were 183 mrem (1.83 mSv) DDE, 183 mrem (1.83 mSv) LDE, and 176 mrem (1.76 mSv) SDE. The mean exposure per case was 0.871 mrem (0.00871 mSv) DDE, 0.871 mrem (0.00871 mSv) LDE, and 0.838 mrem (0.00838 mSv) SDE. The operative surgeon’s mean annual exposure, performing 70 hip arthroscopies per year with 55% involving bony work, was 61.0 mrem (0.610 mSv) DDE, 61.0 mrem (0.610 mSv) LDE, and 58.7 mrem (0.587 mSv) SDE. These results are well below the ICRP annual limits of 50,000 mrem (500 mSv) DDE, 2000 mrem (20 mSv) LDE, and 50,000 mrem (500 mSv) SDE. CONCLUSION: For an experienced hip arthroscopist utilizing fluoroscopy during setup and bony resection, the annual and per-patient exposure to radiation remains well below the recommended ICRP limits. CLINICAL RELEVANCE: Considering the increasing annual frequency of hip arthroscopies being performed, information regarding procedure-specific and cumulative doses of radiation exposure affecting the hip arthroscopist may provide valuable safety information for the orthopaedic community.
format Online
Article
Text
id pubmed-5524238
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-55242382017-08-09 Intraoperative Radiation Exposure During Hip Arthroscopy Salvo, John P. Zarah, Jake Chaudhry, Zaira S. Poehling-Monaghan, Kirsten L. Orthop J Sports Med 53 BACKGROUND: The frequency of hip arthroscopy for the treatment of acute and chronic chondrolabral pathology and femoroacetabular impingement (FAI) has increased exponentially over the past decade. While surgeon and patient radiation exposure has been well documented in other areas of the orthopaedic literature, little is known about the procedure-specific and cumulative doses affecting the hip arthroscopist. PURPOSE: To determine the mean annual radiation exposure to the hip arthroscopist and the mean surgeon exposure per case. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A total of 210 consecutive hip arthroscopies performed in 209 patients by a single surgeon at a single ambulatory surgical center in a cohort consisting of approximately 50% bony (cam and pincer) pathology were prospectively reviewed, documenting the specific procedures performed in each case and the readings from a radiation dosimeter worn by the surgeon during positioning and while performing the procedures. Radiation readings for deep dose–equivalent (DDE), lens dose–equivalent (LDE), and shallow dose–equivalent (SDE) were measured. These readings were compared with the annual radiation dose limit recommendations established by the International Commission on Radiological Protection (ICRP). RESULTS: The total radiation doses for the operative surgeon during all 210 cases were 183 mrem (1.83 mSv) DDE, 183 mrem (1.83 mSv) LDE, and 176 mrem (1.76 mSv) SDE. The mean exposure per case was 0.871 mrem (0.00871 mSv) DDE, 0.871 mrem (0.00871 mSv) LDE, and 0.838 mrem (0.00838 mSv) SDE. The operative surgeon’s mean annual exposure, performing 70 hip arthroscopies per year with 55% involving bony work, was 61.0 mrem (0.610 mSv) DDE, 61.0 mrem (0.610 mSv) LDE, and 58.7 mrem (0.587 mSv) SDE. These results are well below the ICRP annual limits of 50,000 mrem (500 mSv) DDE, 2000 mrem (20 mSv) LDE, and 50,000 mrem (500 mSv) SDE. CONCLUSION: For an experienced hip arthroscopist utilizing fluoroscopy during setup and bony resection, the annual and per-patient exposure to radiation remains well below the recommended ICRP limits. CLINICAL RELEVANCE: Considering the increasing annual frequency of hip arthroscopies being performed, information regarding procedure-specific and cumulative doses of radiation exposure affecting the hip arthroscopist may provide valuable safety information for the orthopaedic community. SAGE Publications 2017-07-21 /pmc/articles/PMC5524238/ /pubmed/28795076 http://dx.doi.org/10.1177/2325967117719014 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc-nd/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License (http://www.creativecommons.org/licenses/by-nc-nd/3.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle 53
Salvo, John P.
Zarah, Jake
Chaudhry, Zaira S.
Poehling-Monaghan, Kirsten L.
Intraoperative Radiation Exposure During Hip Arthroscopy
title Intraoperative Radiation Exposure During Hip Arthroscopy
title_full Intraoperative Radiation Exposure During Hip Arthroscopy
title_fullStr Intraoperative Radiation Exposure During Hip Arthroscopy
title_full_unstemmed Intraoperative Radiation Exposure During Hip Arthroscopy
title_short Intraoperative Radiation Exposure During Hip Arthroscopy
title_sort intraoperative radiation exposure during hip arthroscopy
topic 53
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5524238/
https://www.ncbi.nlm.nih.gov/pubmed/28795076
http://dx.doi.org/10.1177/2325967117719014
work_keys_str_mv AT salvojohnp intraoperativeradiationexposureduringhiparthroscopy
AT zarahjake intraoperativeradiationexposureduringhiparthroscopy
AT chaudhryzairas intraoperativeradiationexposureduringhiparthroscopy
AT poehlingmonaghankirstenl intraoperativeradiationexposureduringhiparthroscopy