Cargando…
Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians
PURPOSE: The aim of this study was to assess inter- and intra-observer variability of arm muscle thickness measured by critical care physicians using bedside ultrasonography (USG). METHODOLOGY: This prospective study included twenty patients admitted with sepsis. Three measurements of thickness of r...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5525479/ https://www.ncbi.nlm.nih.gov/pubmed/28272064 http://dx.doi.org/10.4103/0022-3859.201412 |
_version_ | 1783252644488282112 |
---|---|
author | Hadda, V Kumar, R Dhungana, A Khan, MA Madan, K Khilnani, GC |
author_facet | Hadda, V Kumar, R Dhungana, A Khan, MA Madan, K Khilnani, GC |
author_sort | Hadda, V |
collection | PubMed |
description | PURPOSE: The aim of this study was to assess inter- and intra-observer variability of arm muscle thickness measured by critical care physicians using bedside ultrasonography (USG). METHODOLOGY: This prospective study included twenty patients admitted with sepsis. Three measurements of thickness of right arm muscles of each patient using B-mode USG were taken by two critical care fellows, independently. Intra- and inter-observer reliability was tested using intraclass correlation coefficient (ICC). RESULTS: The mean 1(st), 2(nd), and 3(rd) measurements of muscle thickness recorded by observer 1 and 2 were 23.620 (±4.171) versus 23.840 (±3.849) mm, 23.235 (±3.620) versus 23.625 (±4.062) mm, and 24.125 (±4.098) versus 23.965 (±3.651) mm, respectively. The average muscle thickness measured by first and second observer was 23.660 (±3.834) mm and 23.810 (±3.674) mm, respectively. ICC for intra-observer variability for observer 1 and 2 was 0.964 (95% confidence interval [CI] 0.924–0.985) and 0.949 (95% CI 0.892–0.978), respectively. ICC for inter-observer variability was 0.995 (95% CI 0.988–0.998). CONCLUSIONS: USG is a reliable tool for assessment of arm muscle thickness by critical care physicians. |
format | Online Article Text |
id | pubmed-5525479 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-55254792017-08-08 Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians Hadda, V Kumar, R Dhungana, A Khan, MA Madan, K Khilnani, GC J Postgrad Med Original Article PURPOSE: The aim of this study was to assess inter- and intra-observer variability of arm muscle thickness measured by critical care physicians using bedside ultrasonography (USG). METHODOLOGY: This prospective study included twenty patients admitted with sepsis. Three measurements of thickness of right arm muscles of each patient using B-mode USG were taken by two critical care fellows, independently. Intra- and inter-observer reliability was tested using intraclass correlation coefficient (ICC). RESULTS: The mean 1(st), 2(nd), and 3(rd) measurements of muscle thickness recorded by observer 1 and 2 were 23.620 (±4.171) versus 23.840 (±3.849) mm, 23.235 (±3.620) versus 23.625 (±4.062) mm, and 24.125 (±4.098) versus 23.965 (±3.651) mm, respectively. The average muscle thickness measured by first and second observer was 23.660 (±3.834) mm and 23.810 (±3.674) mm, respectively. ICC for intra-observer variability for observer 1 and 2 was 0.964 (95% confidence interval [CI] 0.924–0.985) and 0.949 (95% CI 0.892–0.978), respectively. ICC for inter-observer variability was 0.995 (95% CI 0.988–0.998). CONCLUSIONS: USG is a reliable tool for assessment of arm muscle thickness by critical care physicians. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5525479/ /pubmed/28272064 http://dx.doi.org/10.4103/0022-3859.201412 Text en Copyright: © 2017 Journal of Postgraduate Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Hadda, V Kumar, R Dhungana, A Khan, MA Madan, K Khilnani, GC Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians |
title | Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians |
title_full | Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians |
title_fullStr | Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians |
title_full_unstemmed | Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians |
title_short | Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians |
title_sort | inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5525479/ https://www.ncbi.nlm.nih.gov/pubmed/28272064 http://dx.doi.org/10.4103/0022-3859.201412 |
work_keys_str_mv | AT haddav interandintraobservervariabilityofultrasonographicarmmusclethicknessmeasurementbycriticalcarephysicians AT kumarr interandintraobservervariabilityofultrasonographicarmmusclethicknessmeasurementbycriticalcarephysicians AT dhunganaa interandintraobservervariabilityofultrasonographicarmmusclethicknessmeasurementbycriticalcarephysicians AT khanma interandintraobservervariabilityofultrasonographicarmmusclethicknessmeasurementbycriticalcarephysicians AT madank interandintraobservervariabilityofultrasonographicarmmusclethicknessmeasurementbycriticalcarephysicians AT khilnanigc interandintraobservervariabilityofultrasonographicarmmusclethicknessmeasurementbycriticalcarephysicians |