Cargando…

Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics

The aim of the present study was to evaluate the effects of femtosecond laser-assisted cataract surgery (FLACS) and phacoemulsification on corneal biomechanics using corneal visualization Scheimpflug technology. The medical records of 50 eyes from 50 patients who received phacoemulsification and int...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Yinjuan, Xu, Lingxiao, Song, Hui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5526192/
https://www.ncbi.nlm.nih.gov/pubmed/28781631
http://dx.doi.org/10.3892/etm.2017.4675
_version_ 1783252769028702208
author Wei, Yinjuan
Xu, Lingxiao
Song, Hui
author_facet Wei, Yinjuan
Xu, Lingxiao
Song, Hui
author_sort Wei, Yinjuan
collection PubMed
description The aim of the present study was to evaluate the effects of femtosecond laser-assisted cataract surgery (FLACS) and phacoemulsification on corneal biomechanics using corneal visualization Scheimpflug technology. The medical records of 50 eyes from 50 patients who received phacoemulsification and intraocular lens implantation because of age-related factors between June 2014 and September 2014 were retrospectively analyzed. FLACS was used in 12 eyes (FLACS group), and conventional phacoemulsification in 38 eyes (PHACO group). The evaluation of corneal biomechanical parameters included the first/second applanation time (A-time1/A-time2), the first/second applanation length (A-length1/A-length2), corneal velocity during the first/second applanation moment (Vin/Vout), highest concavity time, highest concavity-radius (HC-radius), peak distance (PD), deformation amplitude (DA), central corneal thickness (CCT), and intraocular pressure (IOP). The differences in A-length1/A-length2, IOP, CCT, PD, and DA were significant in the PHACO group between those before, 1 week after, and 1 month after surgery. No significant differences in corneal biomechanical parameters were found between those at 1 month after surgery and before surgery. There were significant differences in IOP and CCT in the FLACS group between those before, 1 week after, and 1 month after surgery. There were no significant differences in the other corneal biomechanical parameters. No significant differences were found in corneal biomechanical parameters between those 1 month after surgery and before surgery. There were significant differences in A-length1/A-length2, CCT, PD, and DA between the two groups at 1 week after surgery. There were no significant differences in corneal biomechanical parameters between the two groups at 1 month after surgery. In conclusion, the effect of FLACS on corneal biomechanics is smaller than that of phacoemulsification. The corneal biomechanical parameters are restored to preoperative levels with the healing of the incision, and the reduction of swelling of the tissue near the incision.
format Online
Article
Text
id pubmed-5526192
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-55261922017-08-04 Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics Wei, Yinjuan Xu, Lingxiao Song, Hui Exp Ther Med Articles The aim of the present study was to evaluate the effects of femtosecond laser-assisted cataract surgery (FLACS) and phacoemulsification on corneal biomechanics using corneal visualization Scheimpflug technology. The medical records of 50 eyes from 50 patients who received phacoemulsification and intraocular lens implantation because of age-related factors between June 2014 and September 2014 were retrospectively analyzed. FLACS was used in 12 eyes (FLACS group), and conventional phacoemulsification in 38 eyes (PHACO group). The evaluation of corneal biomechanical parameters included the first/second applanation time (A-time1/A-time2), the first/second applanation length (A-length1/A-length2), corneal velocity during the first/second applanation moment (Vin/Vout), highest concavity time, highest concavity-radius (HC-radius), peak distance (PD), deformation amplitude (DA), central corneal thickness (CCT), and intraocular pressure (IOP). The differences in A-length1/A-length2, IOP, CCT, PD, and DA were significant in the PHACO group between those before, 1 week after, and 1 month after surgery. No significant differences in corneal biomechanical parameters were found between those at 1 month after surgery and before surgery. There were significant differences in IOP and CCT in the FLACS group between those before, 1 week after, and 1 month after surgery. There were no significant differences in the other corneal biomechanical parameters. No significant differences were found in corneal biomechanical parameters between those 1 month after surgery and before surgery. There were significant differences in A-length1/A-length2, CCT, PD, and DA between the two groups at 1 week after surgery. There were no significant differences in corneal biomechanical parameters between the two groups at 1 month after surgery. In conclusion, the effect of FLACS on corneal biomechanics is smaller than that of phacoemulsification. The corneal biomechanical parameters are restored to preoperative levels with the healing of the incision, and the reduction of swelling of the tissue near the incision. D.A. Spandidos 2017-08 2017-06-26 /pmc/articles/PMC5526192/ /pubmed/28781631 http://dx.doi.org/10.3892/etm.2017.4675 Text en Copyright: © Wei et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Wei, Yinjuan
Xu, Lingxiao
Song, Hui
Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics
title Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics
title_full Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics
title_fullStr Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics
title_full_unstemmed Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics
title_short Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics
title_sort application of corvis st to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5526192/
https://www.ncbi.nlm.nih.gov/pubmed/28781631
http://dx.doi.org/10.3892/etm.2017.4675
work_keys_str_mv AT weiyinjuan applicationofcorvissttoevaluatetheeffectoffemtosecondlaserassistedcataractsurgeryoncornealbiomechanics
AT xulingxiao applicationofcorvissttoevaluatetheeffectoffemtosecondlaserassistedcataractsurgeryoncornealbiomechanics
AT songhui applicationofcorvissttoevaluatetheeffectoffemtosecondlaserassistedcataractsurgeryoncornealbiomechanics