Cargando…

Human Summating Potential Using Continuous Loop Averaging Deconvolution: Response Amplitudes Vary with Tone Burst Repetition Rate and Duration

Electrocochleography (ECochG) to high repetition rate tone bursts may have advantages over ECochG to clicks with standard slow rates. Tone burst stimuli presented at a high repetition rate may enhance summating potential (SP) measurements by reducing neural contributions resulting from neural adapta...

Descripción completa

Detalles Bibliográficos
Autores principales: Kennedy, Alana E., Kaf, Wafaa A., Ferraro, John A., Delgado, Rafael E., Lichtenhan, Jeffery T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5529347/
https://www.ncbi.nlm.nih.gov/pubmed/28798660
http://dx.doi.org/10.3389/fnins.2017.00429
_version_ 1783253100160614400
author Kennedy, Alana E.
Kaf, Wafaa A.
Ferraro, John A.
Delgado, Rafael E.
Lichtenhan, Jeffery T.
author_facet Kennedy, Alana E.
Kaf, Wafaa A.
Ferraro, John A.
Delgado, Rafael E.
Lichtenhan, Jeffery T.
author_sort Kennedy, Alana E.
collection PubMed
description Electrocochleography (ECochG) to high repetition rate tone bursts may have advantages over ECochG to clicks with standard slow rates. Tone burst stimuli presented at a high repetition rate may enhance summating potential (SP) measurements by reducing neural contributions resulting from neural adaptation to high stimulus repetition rates. To allow for the analysis of the complex ECochG responses to high rates, we deconvolved responses using the Continuous Loop Averaging Deconvolution (CLAD) technique. We examined the effect of high stimulus repetition rate and stimulus duration on SP amplitude measurements made with extratympanic ECochG to tone bursts in 20 adult females with normal hearing. We used 500 and 2,000 Hz tone bursts of various stimulus durations (12, 6, 3 ms) and repetition rates (five rates ranging from 7.1 to 234.38/s). A within-subject repeated measures (rate x duration) analysis of variance was conducted. We found that, for both 500 and 2,000 Hz stimuli, the mean deconvolved SP amplitudes were larger at faster repetition rates (58.59 and 97.66/s) compared to slower repetition rates (7.1 and 19.53/s), and larger at shorter stimulus duration compared longer stimulus duration. Our concluding hypothesis is that large SP amplitude to short duration stimuli may originate primarily from neural excitation, and large SP amplitudes to long duration, fast repetition rate stimuli may originate from hair cell responses. While the hair cell or neural origins of the SP to various stimulus parameters remains to be validated, our results nevertheless provide normative data as a step toward applying the CLAD technique to understanding diseased ears.
format Online
Article
Text
id pubmed-5529347
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-55293472017-08-10 Human Summating Potential Using Continuous Loop Averaging Deconvolution: Response Amplitudes Vary with Tone Burst Repetition Rate and Duration Kennedy, Alana E. Kaf, Wafaa A. Ferraro, John A. Delgado, Rafael E. Lichtenhan, Jeffery T. Front Neurosci Neuroscience Electrocochleography (ECochG) to high repetition rate tone bursts may have advantages over ECochG to clicks with standard slow rates. Tone burst stimuli presented at a high repetition rate may enhance summating potential (SP) measurements by reducing neural contributions resulting from neural adaptation to high stimulus repetition rates. To allow for the analysis of the complex ECochG responses to high rates, we deconvolved responses using the Continuous Loop Averaging Deconvolution (CLAD) technique. We examined the effect of high stimulus repetition rate and stimulus duration on SP amplitude measurements made with extratympanic ECochG to tone bursts in 20 adult females with normal hearing. We used 500 and 2,000 Hz tone bursts of various stimulus durations (12, 6, 3 ms) and repetition rates (five rates ranging from 7.1 to 234.38/s). A within-subject repeated measures (rate x duration) analysis of variance was conducted. We found that, for both 500 and 2,000 Hz stimuli, the mean deconvolved SP amplitudes were larger at faster repetition rates (58.59 and 97.66/s) compared to slower repetition rates (7.1 and 19.53/s), and larger at shorter stimulus duration compared longer stimulus duration. Our concluding hypothesis is that large SP amplitude to short duration stimuli may originate primarily from neural excitation, and large SP amplitudes to long duration, fast repetition rate stimuli may originate from hair cell responses. While the hair cell or neural origins of the SP to various stimulus parameters remains to be validated, our results nevertheless provide normative data as a step toward applying the CLAD technique to understanding diseased ears. Frontiers Media S.A. 2017-07-27 /pmc/articles/PMC5529347/ /pubmed/28798660 http://dx.doi.org/10.3389/fnins.2017.00429 Text en Copyright © 2017 Kennedy, Kaf, Ferraro, Delgado and Lichtenhan. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Kennedy, Alana E.
Kaf, Wafaa A.
Ferraro, John A.
Delgado, Rafael E.
Lichtenhan, Jeffery T.
Human Summating Potential Using Continuous Loop Averaging Deconvolution: Response Amplitudes Vary with Tone Burst Repetition Rate and Duration
title Human Summating Potential Using Continuous Loop Averaging Deconvolution: Response Amplitudes Vary with Tone Burst Repetition Rate and Duration
title_full Human Summating Potential Using Continuous Loop Averaging Deconvolution: Response Amplitudes Vary with Tone Burst Repetition Rate and Duration
title_fullStr Human Summating Potential Using Continuous Loop Averaging Deconvolution: Response Amplitudes Vary with Tone Burst Repetition Rate and Duration
title_full_unstemmed Human Summating Potential Using Continuous Loop Averaging Deconvolution: Response Amplitudes Vary with Tone Burst Repetition Rate and Duration
title_short Human Summating Potential Using Continuous Loop Averaging Deconvolution: Response Amplitudes Vary with Tone Burst Repetition Rate and Duration
title_sort human summating potential using continuous loop averaging deconvolution: response amplitudes vary with tone burst repetition rate and duration
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5529347/
https://www.ncbi.nlm.nih.gov/pubmed/28798660
http://dx.doi.org/10.3389/fnins.2017.00429
work_keys_str_mv AT kennedyalanae humansummatingpotentialusingcontinuousloopaveragingdeconvolutionresponseamplitudesvarywithtoneburstrepetitionrateandduration
AT kafwafaaa humansummatingpotentialusingcontinuousloopaveragingdeconvolutionresponseamplitudesvarywithtoneburstrepetitionrateandduration
AT ferrarojohna humansummatingpotentialusingcontinuousloopaveragingdeconvolutionresponseamplitudesvarywithtoneburstrepetitionrateandduration
AT delgadorafaele humansummatingpotentialusingcontinuousloopaveragingdeconvolutionresponseamplitudesvarywithtoneburstrepetitionrateandduration
AT lichtenhanjefferyt humansummatingpotentialusingcontinuousloopaveragingdeconvolutionresponseamplitudesvarywithtoneburstrepetitionrateandduration