Cargando…
Deformability based Cell Sorting using Microfluidic Ratchets Enabling Phenotypic Separation of Leukocytes Directly from Whole Blood
The separation of leukocytes from whole blood is a prerequisite for many biological assays. Traditional methods require significant sample volumes and are often undesirable because they expose leukocytes to harsh physical or chemical treatment. Existing microfluidic approaches can work with smaller...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5529452/ https://www.ncbi.nlm.nih.gov/pubmed/28747668 http://dx.doi.org/10.1038/s41598-017-06865-x |
_version_ | 1783253125754257408 |
---|---|
author | Guo, Quan Duffy, Simon P. Matthews, Kerryn Islamzada, Emel Ma, Hongshen |
author_facet | Guo, Quan Duffy, Simon P. Matthews, Kerryn Islamzada, Emel Ma, Hongshen |
author_sort | Guo, Quan |
collection | PubMed |
description | The separation of leukocytes from whole blood is a prerequisite for many biological assays. Traditional methods require significant sample volumes and are often undesirable because they expose leukocytes to harsh physical or chemical treatment. Existing microfluidic approaches can work with smaller volumes, but lack selectivity. In particular, the selectivity of microfluidic systems based on microfiltration is limited by fouling due to clogging. Here, we developed a method to separate leukocytes from whole blood using the microfluidic ratchet mechanism, which filters the blood sample using a matrix of micrometer-scale tapered constrictions. Deforming single cells through such constrictions requires directionally asymmetrical forces, which enables oscillatory flow to create a ratcheting transport that depends on cell size and deformability. Simultaneously, oscillatory flow continuously agitates the cells to limit the contact time with the filter microstructure to prevent adsorption and clogging. We show this device is capable of isolating leukocytes from whole blood with 100% purity (i.e. no contaminant erythrocytes) and <2% leukocytes loss. We further demonstrate the potential to phenotypically sort leukocytes to enrich for granulocytes and lymphocytes subpopulations. Together, this process provides a sensitive method to isolate and sort leukocytes directly from whole blood based on their biophysical properties. |
format | Online Article Text |
id | pubmed-5529452 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-55294522017-08-02 Deformability based Cell Sorting using Microfluidic Ratchets Enabling Phenotypic Separation of Leukocytes Directly from Whole Blood Guo, Quan Duffy, Simon P. Matthews, Kerryn Islamzada, Emel Ma, Hongshen Sci Rep Article The separation of leukocytes from whole blood is a prerequisite for many biological assays. Traditional methods require significant sample volumes and are often undesirable because they expose leukocytes to harsh physical or chemical treatment. Existing microfluidic approaches can work with smaller volumes, but lack selectivity. In particular, the selectivity of microfluidic systems based on microfiltration is limited by fouling due to clogging. Here, we developed a method to separate leukocytes from whole blood using the microfluidic ratchet mechanism, which filters the blood sample using a matrix of micrometer-scale tapered constrictions. Deforming single cells through such constrictions requires directionally asymmetrical forces, which enables oscillatory flow to create a ratcheting transport that depends on cell size and deformability. Simultaneously, oscillatory flow continuously agitates the cells to limit the contact time with the filter microstructure to prevent adsorption and clogging. We show this device is capable of isolating leukocytes from whole blood with 100% purity (i.e. no contaminant erythrocytes) and <2% leukocytes loss. We further demonstrate the potential to phenotypically sort leukocytes to enrich for granulocytes and lymphocytes subpopulations. Together, this process provides a sensitive method to isolate and sort leukocytes directly from whole blood based on their biophysical properties. Nature Publishing Group UK 2017-07-26 /pmc/articles/PMC5529452/ /pubmed/28747668 http://dx.doi.org/10.1038/s41598-017-06865-x Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Guo, Quan Duffy, Simon P. Matthews, Kerryn Islamzada, Emel Ma, Hongshen Deformability based Cell Sorting using Microfluidic Ratchets Enabling Phenotypic Separation of Leukocytes Directly from Whole Blood |
title | Deformability based Cell Sorting using Microfluidic Ratchets Enabling Phenotypic Separation of Leukocytes Directly from Whole Blood |
title_full | Deformability based Cell Sorting using Microfluidic Ratchets Enabling Phenotypic Separation of Leukocytes Directly from Whole Blood |
title_fullStr | Deformability based Cell Sorting using Microfluidic Ratchets Enabling Phenotypic Separation of Leukocytes Directly from Whole Blood |
title_full_unstemmed | Deformability based Cell Sorting using Microfluidic Ratchets Enabling Phenotypic Separation of Leukocytes Directly from Whole Blood |
title_short | Deformability based Cell Sorting using Microfluidic Ratchets Enabling Phenotypic Separation of Leukocytes Directly from Whole Blood |
title_sort | deformability based cell sorting using microfluidic ratchets enabling phenotypic separation of leukocytes directly from whole blood |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5529452/ https://www.ncbi.nlm.nih.gov/pubmed/28747668 http://dx.doi.org/10.1038/s41598-017-06865-x |
work_keys_str_mv | AT guoquan deformabilitybasedcellsortingusingmicrofluidicratchetsenablingphenotypicseparationofleukocytesdirectlyfromwholeblood AT duffysimonp deformabilitybasedcellsortingusingmicrofluidicratchetsenablingphenotypicseparationofleukocytesdirectlyfromwholeblood AT matthewskerryn deformabilitybasedcellsortingusingmicrofluidicratchetsenablingphenotypicseparationofleukocytesdirectlyfromwholeblood AT islamzadaemel deformabilitybasedcellsortingusingmicrofluidicratchetsenablingphenotypicseparationofleukocytesdirectlyfromwholeblood AT mahongshen deformabilitybasedcellsortingusingmicrofluidicratchetsenablingphenotypicseparationofleukocytesdirectlyfromwholeblood |