Cargando…

Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses

This study aimed to compare within-subject blood pressure (BP) variabilities from different measurement techniques. Cuff pressures from three repeated BP measurements were obtained from 30 normotensive and 30 hypertensive subjects. Automatic BPs were determined from the pulses with normalised peak a...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Fangwei, Chen, Fei, Zhu, Mingping, Chen, Aiqing, Zheng, Dingchang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5529640/
https://www.ncbi.nlm.nih.gov/pubmed/28785580
http://dx.doi.org/10.1155/2017/5201069
_version_ 1783253166217756672
author Yang, Fangwei
Chen, Fei
Zhu, Mingping
Chen, Aiqing
Zheng, Dingchang
author_facet Yang, Fangwei
Chen, Fei
Zhu, Mingping
Chen, Aiqing
Zheng, Dingchang
author_sort Yang, Fangwei
collection PubMed
description This study aimed to compare within-subject blood pressure (BP) variabilities from different measurement techniques. Cuff pressures from three repeated BP measurements were obtained from 30 normotensive and 30 hypertensive subjects. Automatic BPs were determined from the pulses with normalised peak amplitude larger than a threshold (0.5 for SBP, 0.7 for DBP, and 1.0 for MAP). They were also determined from cuff pressures associated with the above thresholds on a fitted curve polynomial curve of the oscillometric pulse peaks. Finally, the standard deviation (SD) of three repeats and its coefficient of variability (CV) were compared between the two automatic techniques. For the normotensive group, polynomial curve fitting significantly reduced SD of repeats from 3.6 to 2.5 mmHg for SBP and from 3.7 to 2.1 mmHg for MAP and reduced CV from 3.0% to 2.2% for SBP and from 4.3% to 2.4% for MAP (all P < 0.01). For the hypertensive group, SD of repeats decreased from 6.5 to 5.5 mmHg for SBP and from 6.7 to 4.2 mmHg for MAP, and CV decreased from 4.2% to 3.6% for SBP and from 5.8% to 3.8% for MAP (all P < 0.05). In conclusion, polynomial curve fitting of oscillometric pulses had the ability to reduce automatic BP measurement variability.
format Online
Article
Text
id pubmed-5529640
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-55296402017-08-07 Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses Yang, Fangwei Chen, Fei Zhu, Mingping Chen, Aiqing Zheng, Dingchang Biomed Res Int Research Article This study aimed to compare within-subject blood pressure (BP) variabilities from different measurement techniques. Cuff pressures from three repeated BP measurements were obtained from 30 normotensive and 30 hypertensive subjects. Automatic BPs were determined from the pulses with normalised peak amplitude larger than a threshold (0.5 for SBP, 0.7 for DBP, and 1.0 for MAP). They were also determined from cuff pressures associated with the above thresholds on a fitted curve polynomial curve of the oscillometric pulse peaks. Finally, the standard deviation (SD) of three repeats and its coefficient of variability (CV) were compared between the two automatic techniques. For the normotensive group, polynomial curve fitting significantly reduced SD of repeats from 3.6 to 2.5 mmHg for SBP and from 3.7 to 2.1 mmHg for MAP and reduced CV from 3.0% to 2.2% for SBP and from 4.3% to 2.4% for MAP (all P < 0.01). For the hypertensive group, SD of repeats decreased from 6.5 to 5.5 mmHg for SBP and from 6.7 to 4.2 mmHg for MAP, and CV decreased from 4.2% to 3.6% for SBP and from 5.8% to 3.8% for MAP (all P < 0.05). In conclusion, polynomial curve fitting of oscillometric pulses had the ability to reduce automatic BP measurement variability. Hindawi 2017 2017-07-12 /pmc/articles/PMC5529640/ /pubmed/28785580 http://dx.doi.org/10.1155/2017/5201069 Text en Copyright © 2017 Fangwei Yang et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yang, Fangwei
Chen, Fei
Zhu, Mingping
Chen, Aiqing
Zheng, Dingchang
Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses
title Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses
title_full Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses
title_fullStr Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses
title_full_unstemmed Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses
title_short Significantly Reduced Blood Pressure Measurement Variability for Both Normotensive and Hypertensive Subjects: Effect of Polynomial Curve Fitting of Oscillometric Pulses
title_sort significantly reduced blood pressure measurement variability for both normotensive and hypertensive subjects: effect of polynomial curve fitting of oscillometric pulses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5529640/
https://www.ncbi.nlm.nih.gov/pubmed/28785580
http://dx.doi.org/10.1155/2017/5201069
work_keys_str_mv AT yangfangwei significantlyreducedbloodpressuremeasurementvariabilityforbothnormotensiveandhypertensivesubjectseffectofpolynomialcurvefittingofoscillometricpulses
AT chenfei significantlyreducedbloodpressuremeasurementvariabilityforbothnormotensiveandhypertensivesubjectseffectofpolynomialcurvefittingofoscillometricpulses
AT zhumingping significantlyreducedbloodpressuremeasurementvariabilityforbothnormotensiveandhypertensivesubjectseffectofpolynomialcurvefittingofoscillometricpulses
AT chenaiqing significantlyreducedbloodpressuremeasurementvariabilityforbothnormotensiveandhypertensivesubjectseffectofpolynomialcurvefittingofoscillometricpulses
AT zhengdingchang significantlyreducedbloodpressuremeasurementvariabilityforbothnormotensiveandhypertensivesubjectseffectofpolynomialcurvefittingofoscillometricpulses